Approximate expressions for the lowest dipole resonance frequency of an elastic sphere in an elastic solid

1991 ◽  
Vol 89 (6) ◽  
pp. 3002-3003
Author(s):  
Kurt P. Scharnhorst
1878 ◽  
Vol 27 (185-189) ◽  
pp. 419-424

Sir W. Thomson’s investigation of the bodily tides of an elastic sphere has gone far to overthrow the idea of a semi-fluid interior to the earth, yet geologists are so strongly impressed by the fact that enormous masses of rock have been poured out of volcanic vents in the earth’s surface, that the belief is not yet extinct that we live on a thin shell over a sea of molten lava. It appeared to me, therefore, to be of interest to investigate the consequences which would arise from the supposition that the matter constituting the earth is of a viscous or imperfectly elastic nature. In this paper I follow out these hypo-theses, and it will be seen that the results are fully as hostile to the idea of any great mobility of the interior of the earth as are those of Sir W. Thomson. I begin by showing that the equations of flow of an incompressible viscous fluid have precisely the same form as those of strain of an incompressible elastic solid, at least when inertia is neglected. Hence, every problem about the strains of the latter has its analogue touching the flow of the former. This being so, the solution of Sir W. Thomson’s problem of the bodily tides of an elastic sphere may be adapted to give the bodily tides of a viscous spheroid. Sir W. Thomson, however, introduces the effects of the mutual gravitation of the parts of the sphere, by a synthetical method, after he has found the state of internal strain of an elastic sphere devoid of gravitational power The parallel synthetical method becomes, in the case of the viscous spheroid, somewhat complex, and I have preferred to adapt the solution analytically so as to include gravitation.


2000 ◽  
Vol 80 (12) ◽  
pp. 2827-2840 ◽  
Author(s):  
J. W. Morris Jr, C. R. K Renn

2020 ◽  
Vol 14 (4) ◽  
pp. 7396-7404
Author(s):  
Abdul Malek Abdul Wahab ◽  
Emiliano Rustighi ◽  
Zainudin A.

Various complex shapes of dielectric electro-active polymer (DEAP) actuator have been promoted for several types of applications. In this study, the actuation and mechanical dynamics characteristics of a new core free flat DEAP soft actuator were investigated. This actuator was developed by Danfoss PolyPower. DC voltage of up to 2000 V was supplied for identifying the actuation characteristics of the actuator and compare with the existing formula. The operational frequency of the actuator was determined by dynamic testing. Then, the soft actuator has been modelled as a uniform bar rigidly fixed at one end and attached to mass at another end. Results from the theoretical model were compared with the experimental results. It was found that the deformation of the current actuator was quadratic proportional to the voltage supplied. It was found that experimental results and theory were not in good agreement for low and high voltage with average percentage error are 104% and 20.7%, respectively. The resonance frequency of the actuator was near 14 Hz. Mass of load added, inhomogeneity and initial tension significantly affected the resonance frequency of the soft actuator. The experimental results were consistent with the theoretical model at zero load. However, due to inhomogeneity, the frequency response function’s plot underlines a poor prediction where the theoretical calculation was far from experimental results as values of load increasing with the average percentage error 15.7%. Hence, it shows the proposed analytical procedure not suitable to provide accurate natural frequency for the DEAP soft actuator.


2007 ◽  
Vol 14 (1) ◽  
pp. 42 ◽  
Author(s):  
TRAN DUC THIEP ◽  
NGUYEN VAN DO ◽  
NGUYEN KHAC THI ◽  
TRUONG THI AN ◽  
NGUYEN NGOC SON

Mictrorons are accelerators of electrons and are simultaneous sources of bremsstrahlung photon flux and fission neutrons. In 1982, a microtron of seventeen trajectories Microtron MT - 17 was put into operation at the National Institute of Physics of Vietnam. Though very modest, microtons are very useful for developing countries such as Vietnam in both fundamental and applied physics research. During the recent years by using the above mentioned MT - 17 and microtrons from other institutes we have carried out different investigations. In this report we present some results obtained in the studies of photonuclear reactions and photon activation analysis in the giant dipole resonance region.


2020 ◽  
Vol 46 (3) ◽  
pp. 182-189 ◽  
Author(s):  
Davide Farronato ◽  
Mattia Manfredini ◽  
Michele Stocchero ◽  
Mattia Caccia ◽  
Lorenzo Azzi ◽  
...  

The aim of this study was to evaluate the influence of bone quality, drilling technique, implant diameter, and implant length on insertion torque (IT) and resonance frequency analysis (RFA) of a prototype-tapered implant with knife-edge threads. The investigators hypothesized that IT would be affected by variations in bone quality and drilling protocol, whereas RFA would be less influenced by such variables. The investigators implemented an in vitro experiment in which a prototype implant was inserted with different testing conditions into rigid polyurethane foam blocks. The independent variables were: bone quality, drilling protocol, implant diameter, and implant length. Group A implants were inserted with a conventional drilling protocol, whereas Group B implants were inserted with an undersized drilling protocol. Values of IT and RFA were measured at implant installation. IT and RFA values were significantly correlated (Pearson correlation coefficient: 0.54). A multivariable analysis showed a strong model. Higher IT values were associated with drilling protocol B vs A (mean difference: 71.7 Ncm), implant length (3.6 Ncm increase per mm in length), and substrate density (0.199 Ncm increase per mg/cm3 in density). Higher RFA values were associated with drilling protocol B vs A (mean difference: 3.9), implant length (1.0 increase per mm in length), and substrate density (0.032 increase per mg/cm3 in density). Implant diameter was not associated with RFA or IT. Within the limitations of an in vitro study, the results of this study suggest that the studied implant can achieve good level of primary stability in terms of IT and RFA. A strong correlation was found between values of IT and RFA. Both parameters are influenced by the drilling protocol, implant length, and substrate density. Further studies are required to investigate the clinical response in primary stability and marginal bone response.


Sign in / Sign up

Export Citation Format

Share Document