scholarly journals Antibody-direct epifluorescent filter technique for rapid, direct enumeration of Escherichia coli O157:H7 in beef.

1994 ◽  
Vol 60 (10) ◽  
pp. 3553-3559 ◽  
Author(s):  
M L Tortorello ◽  
D S Stewart
1996 ◽  
Vol 59 (10) ◽  
pp. 1072-1075 ◽  
Author(s):  
LAWRENCE RESTAINO ◽  
H. JEFFREY CASTILLO ◽  
DIANA STEWART ◽  
MARY LOU TORTORELLO

Rapid screening of beef for the presence of Escherichia coli O157:H7 was shown to be feasible using a 10-h enrichment in modified buffered peptone water and the antibody-direct epifluorescent filter technique (Ab-DEFT). The Ab-DEFT involved membrane filtration, fluorescent antibody staining and epifluorescence microscopy and was accomplished in less than 1 h. The procedure allowed detection of the pathogen artificially inoculated into beef patties at 0.1 CFU/g. The 10-h nonselective enrichment broth supported rapid growth, which provided sufficient numbers of cells for a positive determination by the Ab-DEFT after fewer than 10 microscope fields were scanned using a 40× objective lens. Immunomagnetic separation using anti-E. coli O157 Dynabeads® was used to confirm presumptively positive cultures within 24 h. The ease and rapidity of the Ab-DEFT may provide a substantial time and cost savings to the beef industry for screening beef for the presence of E. coli O157:H7.


1999 ◽  
Vol 65 (4) ◽  
pp. 1397-1404 ◽  
Author(s):  
Lawrence Goodridge ◽  
Jinru Chen ◽  
Mansel Griffiths

ABSTRACT In this paper we describe evaluation and characterization of a novel assay that combines immunomagnetic separation and a fluorescently stained bacteriophage for detection of Escherichia coliO157:H7 in broth. When it was combined with flow cytometry, the fluorescent-bacteriophage assay (FBA) was capable of detecting 104 cells/ml. A modified direct epifluorescent-filter technique (DEFT) was employed in an attempt to estimate bacterial concentrations. Using regression analysis, we calculated that the lower detection limit was between 102 and 103cells/ml; however, the modified DEFT was found to be an unreliable method for determining bacterial concentrations. The results of this study show that the FBA, when combined with flow cytometry, is a sensitive technique for presumptive detection of E. coliO157:H7 in broth cultures.


1998 ◽  
Vol 61 (11) ◽  
pp. 1425-1430 ◽  
Author(s):  
M. L. TORTORELLO ◽  
K. F. REINEKE ◽  
D. S. STEWART ◽  
R. B. RAYBOURNE

Six methods were compared for detection of three strains of Escherichia coli O157:H7 in enrichments of inoculated apple juice. Juice was inoculated at levels varying from 0.1 to 100 CFU/ml and centrifuged after ovemight storage at 4°C, and pellets were incubated at 37°C in nonselective enrichment broth. At hourly intervals between 5 and 10 h and at 24 h, the enrichments were tested for E. coli O157:H7 by direct fluorescent antibody (DFA), antibody-direct epifluorescent filter technique (Ab-DEFT), direct selective plating on sorbitol MacConkey agar (SMA), immunomagnetic separation coupled to either selective plating (IMS-SMA) or the polymerase chain reaction (IMS-PCR), and flow cytometry (FC). The most consistent detection of 0.1 CFU/ml of the slowest growing strain of the pathogen was provided by the IMS-SMA and IMS-PCR after 8 h of enrichment. The time required for detection at the level of 0.1 CFU/ml for each assay was Ab-DEFT, 11 h; IMS-PCR, 16 h; FC, 24 h; IMS-SMA, 32 h; and SMA, 48 h. Absolute detection limits (without enrichment) were: IMS-PCR, 103 CFU/ml; Ab-DEFT and IMS-SMA, 104 CFU/ml; SMA, 105 CFU/ml; and DFA, 106 CFU/ml. Recovery of the pathogen (10 CFU/ml) in apple juice after 28 days of 4°C storage was possible by means of an 8-h enrichment and Ab-DEFT, IMS-PCR, or IMS-SMA.


1993 ◽  
Vol 56 (8) ◽  
pp. 672-677 ◽  
Author(s):  
MARY L. TORTORELLO ◽  
STEVEN M. GENDEL

In a modification of the direct epifluorescent filter technique (DEFT), direct fluorescent antibody staining was used for the rapid (<1 h), specific enumeration of foodbome Escherichia coli 0157:H7 by epifluorescence microscopy. Cell counts obtained by this method (Ab-DEFT) correlated well with DEFT counts obtained by acridine orange staining and with viable plate counts ranging from 108 to 101 cells per ml for pure cultures in buffer. Ab-DEFT also was effective for counting E. coli 0157:H7 cells inoculated into milk and juice; the sensitivity limit was about 103 for milk. The highly specific nature of the technique was demonstrated by enumeration of E. coli 0157:H7 cells in the presence of large numbers of indigenous spoilage microorganisms in milk. This is the first known demonstration of the combination of DEFT and antibody probe technology for the specific enumeration of a microbe directly in food without a growth or enrichment step.


2006 ◽  
Vol 148 (6) ◽  
pp. 289-295 ◽  
Author(s):  
C. Zweifel ◽  
M. Kaufmann ◽  
J. Blanco ◽  
R. Stephan

2020 ◽  
Vol 23 (3) ◽  
pp. 310-318
Author(s):  
K. Koev ◽  
T. Stoyanchev ◽  
G. Zhelev ◽  
P. Marutsov ◽  
K. Gospodinova ◽  
...  

The purpose of this study was to detect the presence of shiga-toxin producing Escherichia coli (STEC) in faeces of healthy dairy cattle and to determine the sensitivity of isolates to several anti­microbial drugs. A total of 1,104 anal swab samples originating from 28 cattle farms were examined. After the primary identification, 30 strains were found to belong to serogroup О157. By means of conventional multiplex PCR, isolates were screened for presence of resistance genes stx1, stx2 and eaeА. Twenty-nine strains possesses amplicons with a size corresponding to genes stx2 and eaeA, one had amplicons also for the stx1 gene and one lacked amplicons of all three genes. Twenty-eight strains demonstrated amplicons equivalent to gene H7. The results from phenotype analysis of resistance showed preserved sensitivity to ceftriaxone, ceftazidime, cefotaxime, cephalothin, streptomycin, gentamicin, tetracycline, enrofloxacin and combinations sulfamethoxazole/trimethoprim and amoxicillin/clavulanic acid. Sensitivity to ampicillin was relatively preserved, although at a lower extent.


Sign in / Sign up

Export Citation Format

Share Document