lower detection
Recently Published Documents


TOTAL DOCUMENTS

261
(FIVE YEARS 78)

H-INDEX

26
(FIVE YEARS 7)

2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Xuexiang Lin ◽  
Xiao-Yu Liu ◽  
Bo Zhang ◽  
Ai-Qing Qin ◽  
Kwok-Min Hui ◽  
...  

AbstractCurrent methods used for diagnosis of acute infection of pathogens rely on detection of nucleic acids, antigens, or certain classes of antibodies such as IgM. Here we report a virus enzyme assay as an alternative to these methods for detection of acute viral infection. In this method, we used a luciferin derivative as the substrate for detection of the enzyme activity of influenza viral neuraminidase as a means for diagnosis of influenza. The resulting commercial test, the qFLU Dx Test, uses a different supply chain that does not compete with those for the current tests. The assay reagents were formulated as a master mix that accommodated both the neuraminidase and luciferase reactions, thereby enabling rapid and prolonged production of stable light signal in the presence of influenza virus in the sample. The assay was evaluated using depository throat swab specimens. As expected, the assay exhibited similar detection rates for all influenza types and subtypes except for A(H7N9), which exhibited lower detection rate due to lower viral titer in the specimens. When throat swab specimens were diluted with the sample buffer of the test kit and tested with the qFLU Dx Test. The sensitivity and specificity were 82.41% (95% confidence interval: 79.66–85.84%) and 95.39% (95% confidence interval: 94.32–96.46%), respectively, for these diluted specimens in comparison to a real-time polymerase chain reaction assay. The uniqueness of the qFLU Dx Test as an enzymatic assay makes it highly complementary with currently available methods.


Author(s):  
Weixu Feng ◽  
Guorui Fu ◽  
Yujuan Huang ◽  
Yan Zhao ◽  
Hongxia Yan ◽  
...  

The copolymerization between 4-VP-PHI, MMA and the Eu3+-complex results in white light emitting Eu3+-metallopolymer, which not only has a lower detection limit, but also a more remarkable color change compared to 4-VP-PHI for the sensing of Zn2+.


2021 ◽  
Vol 11 (1) ◽  
pp. 1-6
Author(s):  
Abdelrahim Ahmed Mohammed Ate ◽  
Sohila Mohamed

This paper explains the Universal Software Radio Peripheral (USRP) Experiment results of Spectrum Sensing Algorithms based on the Energy Ration Algorithm for Cognitive Radio Networks which is latterly suggested in Spectrum observation for OFDM-Based Cognitive Radio Networks by using Energy Ratio Algorithm. This is completed through detecting the variance in the strength of the signal during a variety of confined OFDM subcarriers are used to ensure that the availability of the essential user is facilely discovered. Extensive experiments are performed, in particular, the effects of Signal to Noise Ratio (SNR). This paper observed that the experimental results gave lower detection performance compared to the simulation results. That’s due to existence of other systems which operate on same frequency band of 2.4GHz.


2021 ◽  
Vol 17 (12) ◽  
pp. 2495-2504
Author(s):  
Xiangchen Li ◽  
Subash C. B. Gopinath ◽  
Xin Peng ◽  
Jiudi Lv

An aptasensor was developed on an interdigitated microelectrode (IDME) by current-volt sensing for the diagnosis of ulcerative colitis by detecting the biomarker lipocalin-2. Higher immobilization of the anti-lipocalin-2 aptamer as a probe was achieved by using sodium dodecyl benzenesulfonate-aided zeolite particles. FESEM and FETEM observations revealed that the size of the zeolite particles was <200 nm, and they displayed a uniform distribution and spherical shape. XPS analysis attested the occurrence of Si, Al, and O groups on the zeolite particles. Zeolite particles were immobilized on IDME by a (3-aminopropyl)-trimethoxysilane amine linker, and then, the aptamer as the probe was tethered on the zeolite particles through a biotin-streptavidin strategy assisted by a bifunctional aldehyde linker. Due to the high occupancy of the aptamer and the efficient electric transfer from zeolite particles, higher changes in current can be observed upon interaction of the aptamer with lipocalin-2. The lower detection of lipocalin-2 was noted as 10 pg/mL, with a linear range from 10 pg/mL to 1 μg/mL and a linear regression equation of y=8E−07x+8E−08; R2 = 0.991. Control experiments with complementary aptamer and matrix metalloproteinase-9 indicate the specific detection of lipocalin-2. Furthermore, spiking lipocalin-2 in human serum does not interfere with the identification.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Nurlatifah ◽  
Haruhiko Nakata

AbstractPlastic debris has gained attention as anthropogenic waste in the environment, but less concerned given to metal waste despite its high abundance in aquatic environment. Metal packaging, such as can, utilizes polymeric coating films as barrier between metals and products which leads to be potential source of microplastic pollution. In this study, 27 beer cans from 16 countries for both body and lid parts as well as inside and outside layers were investigated. Despite the country’s origin, epoxy resin was the major polymeric coating used in all beer cans for lid (inside and outside) and body (inside). Whereas poly(1,2-butanediol isophthalate) was frequently used for outside layer of can body. DEHP and BHT were detected in almost all samples with the highest concentration of 5300 ng/g and 520 ng/g. Despite its lower detection frequency, DOA was detected as high as 9600 ng/g in Belgian beer can. There was no apparent relationship present between the home countries of beer cans and amount of additives used. Despite of being broken down, additives concentration in one environmental sample was found to be one to two orders of magnitude higher compared to the new can. This result proved that adsorption of chemical additives took place in the environment and degraded metal debris may become source of microplastic with higher risk of additives pollution in the environment.


2021 ◽  
Author(s):  
Yunxia Yang ◽  
Qian Liu ◽  
j chen ◽  
y zhao ◽  
b chen ◽  
...  

Abstract The electrode material is vital for the performance of the electrochemical biosensor. Lately, many nanomaterials have been developed to improve the sensitivity and detection efficiency of the biosensors. In this work, a kind of one-dimensional nanomaterials, the CuPt alloy nanotubes with an open end (CuPt alloy NTs-AOE), was explored. The nanotubes with an open end can provide a larger electrochemical active surface area and more active sites for the immobilization of enzyme. The CuPt alloy displays excellent conductivity and catalytic activity. In addition, the Cu shows the great affinity to thio-compounds, which can greatly enhance the detection efficiency and sensitivity. As a result, the prepared biosensor demonstrates the wider linear range of 9.98×10-10 - 9.98×10-5 g/L for fenitrothion and 9.94×10-11 - 9.94×10-4 g/L for dichlorvos (as model OPs ) and with the lower detection limit of 1.84 ×10-10 g/L and 6.31×10-12 g/L (S/N = 3), respectively. Besides, the biosensor has been used to detect the real samples and obtains satisfactory recoveries (95.58 % - 100.56 %).


2021 ◽  
Vol 12 (4) ◽  
pp. 2374-2382
Author(s):  
Annapoorna V ◽  
Ravindhranath K ◽  
Sreenivasa Rao B ◽  
Rao P Y G ◽  
Venugopal K

Blonanserin an antipsychotic novel drug used for the treatment of schizophrenia has antagonist properties for dopamine D2 and serotonin 5-HT2. On the other hand, it lacks adrenergic-α1, muscarinic M1, and histamine H1 antagonist activities. Clinical studies demonstrated in Japan had shown to be more effective for treating negative as well as positive schizophrenic symptoms. This drug was accepted and approved worldwide in the treatment of schizophrenia. A new HPLC method was developed and validated for the estimation of Impurities of Blonanserin (BNS) to ensure that the methodology meets the requirements of the target analysis application. Active and efficient chromatographic separation was achieved on a  Zorbax Bonus RP EP C18 column having a particle size of 5μm, with dimensions of 250mm × 4.6 mm, mobile phase containing pH 2.4 buffer and Organic, with 1.0 ml /min flow rate,  column oven temperature at 30oC and the eluent detection at 245 nm. The method shows well-separated impurities, is specific without interference from blank solution with resolution more than 1.2 between any of the impurity, correlation coefficient more than 0.99 showing good linearity; mean recovery ranging from 97% to 105% and is very sensitive at lower detection and quantification limits. This method was well developed and has been applied successfully to monitor and estimate impurities in Blonanserin.


Chemosensors ◽  
2021 ◽  
Vol 9 (10) ◽  
pp. 284
Author(s):  
Zhijia Liao ◽  
Yao Yu ◽  
Zhenyu Yuan ◽  
Fanli Meng

In this paper, ZnO-TiO2-rGO nanocomposites were successfully synthesized by the hydrothermal method. The morphology and structure of the synthesized nanomaterials were characterized by SEM, XRD, HRTEM, and XPS. Butanone is a typical ketone product. The vapors are extremely harmful once exposed, triggering skin irritation in mild cases and affecting our breathing in severe cases. In this paper, the gas-sensing properties of TiO2, ZnO, ZnO-TiO2, and ZnO-TiO2-rGO nanomaterials to butanone vapor were studied. The optimum operating temperature of the ZnO-TiO2-rGO sensor is 145 °C, which is substantially lower than the other three sensors. The selectivity for butanone vapor is greatly improved, and the response is 5.6 times higher than that of other organic gases. The lower detection limit to butanone can reach 63 ppb. Therefore, the ZnO-TiO2-rGO sensor demonstrates excellent gas-sensing performance to butanone. Meanwhile, the gas-sensing mechanism of the ZnO-TiO2-rGO sensor to butanone vapor was also analyzed.


Sensors ◽  
2021 ◽  
Vol 21 (18) ◽  
pp. 6301
Author(s):  
Dorin Dăscălescu ◽  
Constantin Apetrei

Levodopa is a precursor of dopamine, having important beneficial effects in the treatment of Parkinson’s disease. In this study, levodopa was accurately detected by means of cyclic voltammetry using carbon-based (C-SPCE), mesoporous carbon (MC-SPCE) and ordered mesoporous carbon (OMC-SPCE)-modified screen-printed sensors. Screen-printed carbon sensors were initially used for the electrochemical detection of levodopa in a 10−3 M solution at pH 7.0. The mesoporous carbon with an organized structure led to better electroanalysis results and to lower detection and quantification limits of the OMC-SPCE sensor as compared to the other two studied sensors. The range of linearity obtained and the low values of the detection (0.290 µM) and quantification (0.966 µM) limit demonstrate the high sensitivity and accuracy of the method for the determination of levodopa in real samples. Therefore, levodopa was detected by means of OMC-SPCE in three dietary supplements produced by different manufacturers and having various concentrations of the active compound, levodopa. The results obtained by cyclic voltammetry were compared with those obtained by using the FTIR method and no significant differences were observed. OMC-SPCE proved to be stable, and the electrochemical responses did not vary by more than 3% in repeated immersions in a solution with the same concentration of levodopa. In addition, the interfering compounds did not significantly influence the peaks related to the presence of levodopa in the solution to be analyzed.


2021 ◽  
pp. 219256822110394
Author(s):  
Jan-Helge Klingler ◽  
Ulrich Hubbe ◽  
Christoph Scholz ◽  
Florian Volz ◽  
Roland Roelz ◽  
...  

Study Design: Prospective cohort study. Objectives: The purpose of this prospective study was to evaluate a protocol for radiation-sparing kyphoplasty by assessing dosemetrically recorded radiation exposures to both patient and surgeon. Methods: This prospective clinical study examines the radiation exposure to patient and surgeon during single-level kyphoplasty in 32 thoracolumbar osteoporotic vertebral body fractures (12 OF 2, 9 OF 3, 11 OF 4 types) using a radiation aware surgical protocol between May 2017 and November 2019. The radiation exposure was measured at different locations using film, eye lens and ring dosemeters. Dose values are reported under consideration of lower detection limits of each dosemeter type. Results: A high proportion of dosemeter readings was below the lower detection limits, especially for the surgeon (>90%). Radiation exposure to the surgeon was highest at the unprotected thyroid gland (0.053 ± 0.047 mSv), however only slightly above the lower detection limit of dosemeters (0.044 mSv). Radiation exposure to the patient was highest at the chest (0.349 ± 0.414 mSv) and the gonad (0.186 ± 0.262 mSv). Fluoroscopy time, dose area product and number of fluoroscopic images were 46.0 ± 17.9 sec, 124 ± 109 cGy×cm2, and 35 ± 13 per kyphoplasty, respectively. Back pain significantly improved from 6.8 ± 1.6 to 2.5 ± 1.7 on the numeric rating scale on the first postoperative day ( P < 0.0001). Conclusions: The implementation of a strict intraoperative radiation protection protocol allows for safely performed kyphoplasty with ultra-low radiation exposure for the patient and surgeon without exceeding the annual occupational dose limits. Trial registration: The study was registered in the German Clinical Trials Register (DRKS00011908, registration date 16/05/2017).


Sign in / Sign up

Export Citation Format

Share Document