Rhenium Nanoclusters as Modifiers of Immunosensors in the Determination of Tricyclic Antidepressants

2021 ◽  
Vol 76 (12) ◽  
pp. 1455-1467
Author(s):  
E. P. Medyantseva ◽  
E. R. Gazizullina ◽  
D. V. Brusnitsyn ◽  
M. A. Ziganshin ◽  
Yu. G. Elistratova ◽  
...  
2016 ◽  
Vol 12 (6) ◽  
pp. 560-567
Author(s):  
Marwa F. Mansour ◽  
Ehab F. El-Kady ◽  
Mona M. Abd El-Moety ◽  
Nabawia M. El-Guindi ◽  
Ann Van Schepdael ◽  
...  

Molecules ◽  
2021 ◽  
Vol 26 (11) ◽  
pp. 3101
Author(s):  
Mariana N. Oliveira ◽  
Oriana C. Gonçalves ◽  
Samir M. Ahmad ◽  
Jaderson K. Schneider ◽  
Laiza C. Krause ◽  
...  

This work entailed the development, optimization, validation, and application of a novel analytical approach, using the bar adsorptive microextraction technique (BAμE), for the determination of the six most common tricyclic antidepressants (TCAs; amitriptyline, mianserin, trimipramine, imipramine, mirtazapine and dosulepin) in urine matrices. To achieve this goal, we employed, for the first time, new generation microextraction devices coated with convenient sorbent phases, polymers and novel activated carbons prepared from biomaterial waste, in combination with large-volume-injection gas chromatography-mass spectrometry operating in selected-ion monitoring mode (LVI-GC-MS(SIM)). Preliminary assays on sorbent coatings, showed that the polymeric phases present a much more effective performance, as the tested biosorbents exhibited low efficiency for application in microextraction techniques. By using BAμE coated with C18 polymer, under optimized experimental conditions, the detection limits achieved for the six TCAs ranged from 0.2 to 1.6 μg L−1 and, weighted linear regressions resulted in remarkable linearity (r2 > 0.9960) between 10.0 and 1000.0 μg L−1. The developed analytical methodology (BAμE(C18)/LVI-GC-MS(SIM)) provided suitable matrix effects (90.2–112.9%, RSD ≤ 13.9%), high recovery yields (92.3–111.5%, RSD ≤ 12.3%) and a remarkable overall process efficiency (ranging from 84.9% to 124.3%, RSD ≤ 13.9%). The developed and validated methodology was successfully applied for screening the six TCAs in real urine matrices. The proposed analytical methodology proved to be an eco-user-friendly approach to monitor trace levels of TCAs in complex urine matrices and an outstanding analytical alternative in comparison with other microextraction-based techniques.


1988 ◽  
Vol 34 (11) ◽  
pp. 2348-2351 ◽  
Author(s):  
R C Dorey ◽  
S H Preskorn ◽  
P K Widener

Abstract The tricyclic antidepressants amitriptyline, nortriptyline, imipramine, and desipramine in serum of patients taking one of the drugs were quantified in two laboratories by high-performance liquid chromatography (HPLC) and enzyme-multiplied immunoassay (EMIT; Syva). Results for split samples were highly correlated, but EMIT gave higher results in most cases, and the slopes of the correlation lines for each analyte were greater than 1. Detection limits for the two procedures were such that 18% of the EMIT results for the drug(s) were considered negative, as compared with 4% of the HPLC results. Additional assay of desmethyl or hydroxy antidepressant metabolites by HPLC did not explain the higher EMIT results. The relatively high detection limit for EMIT greatly limits its use in therapeutic drug monitoring, where low concentrations of tricyclic antidepressants are as important as high ones for dose adjustment or determination of compliance. Other problems with EMIT measurement of tricyclic antidepressants are discussed.


2014 ◽  
Vol 88 ◽  
pp. 660-665 ◽  
Author(s):  
Erin E. Chambers ◽  
Matthew J. Woodcock ◽  
Jessalynn P. Wheaton ◽  
Teresa M. Pekol ◽  
Diane M. Diehl

Sign in / Sign up

Export Citation Format

Share Document