G152 The utility of cardiac magnetic resonance and 2D echocardiography in evaluating changes in pulmonary regurgitation severity and right ventricular volumes following primary tetralogy of fallot repair and pulmonary valve replacement

2016 ◽  
Vol 101 (Suppl 1) ◽  
pp. A79-A80
Author(s):  
O Rae ◽  
O Uzun ◽  
A Wood
Author(s):  
Simone Ghiselli ◽  
Cristina Carro ◽  
Nicola Uricchio ◽  
Giuseppe Annoni ◽  
Stefano M Marianeschi

Abstract OBJECTIVES Chronic pulmonary valve (PV) regurgitation is a common late sequela after repair of congenital heart diseases like tetralogy of Fallot or pulmonary stenosis, leading to right ventricular dilatation and failure and increased late morbidity and mortality. Timely reoperation may lead to a complete right ventricular recovery. An injectable PV allows pulmonary valve replacement, with or without cardiopulmonary bypass, under direct observation, thereby minimizing the impact of surgery on cardiac function. The aim of this study was to evaluate the feasibility and mid- to long-term clinical outcomes with this device. METHODS From April 2007 to October 2019, a total of 85 symptomatic patients with severe pulmonary regurgitation or pulmonary stenosis underwent pulmonary valve replacement with an injectable stented pulmonary prosthesis. Data were collected from the international proctoring registry. Mean patient age was 26.7 years. The underlying diagnosis was repaired tetralogy of Fallot in 69.4% patients; moderate or severe pulmonary regurgitation was present in 72.9%. All patients had echocardiographic scans before the operation and during the follow-up period. A total of 54.1% patients also had preoperative/postoperative cardiac magnetic resonance imaging (MRI) or catheterization; 25.9% had off-pump implants. In 53% patients, pulmonary valve replacement was associated with the repair of other cardiac defects. RESULTS Minor postoperative complications were observed in 10.8% patients. The overall mortality rate was 2.3%; mortality after valve replacement was linked to a severe cardiac insufficiency and it was not related to a prosthesis failure; 1 prosthesis was explanted from 1 patient because of endocarditis, and 6% of patients developed PV stenosis; minor complications occurred in 4.8%. The mean follow-up period was 4.8 years (2 months–12.7 years); 42% of the patients were followed for more than 5 years. Follow-up echocardiography and cardiac MRI showed a significant reduction in RV size and low gradients across the PV. CONCLUSIONS An injectable PV may be implanted without cardiopulmonary bypass and in a hybrid operating theatre with minimal surgical impact. The bioprosthesis, available up to large sizes, has a low profile, laminar flow and no risk of coronary artery compression. Incidence of endocarditis is rare. The lack of a suture ring permits the implant of a relatively larger prosthesis, thereby avoiding a right ventricular outflow tract obstruction. This device permits future percutaneous valve-in-valve procedures, if needed. Results concerning durability are encouraging, and mid- to long-term haemodynamic performance is excellent.


Author(s):  
Giacomo Rozzi ◽  
Francesco Paolo Lo Muzio ◽  
Lorenzo Fassina ◽  
Stefano Rossi ◽  
Rosario Statello ◽  
...  

Abstract OBJECTIVES Indications for and timing of pulmonary valve replacement (PVR) after tetralogy of Fallot repair are controversial. Among magnetic resonance imaging indices proposed to time valve replacement, a right ventricular (RV) end-diastolic volume index greater than 160 ml/m2 is often used. Recent evidence suggests that this value may still identify patients with irreversible RV dysfunction, thus hindering recovery. Our goal was to define, using intraoperative video kinematic evaluation, whether a relationship exists between timing of PVR and early functional recovery after surgery. METHODS Between November 2016 and November 2018, a total of 12 consecutive patients aged 27.1 ± 19.1 years underwent PVR on average 22.2 ± 13.3 years after tetralogy of Fallot repair. Mean RV end-diastolic volume evident on the magnetic resonance images was 136.9 ± 35.7 ml/m2. Intraoperative cardiac kinematics were assessed by video kinematic evaluation via a high-speed camera acquiring videos at 200 fps before and after valve replacement. RESULTS Patients presenting with RV end-diastolic volume <147 ml/m2 were significantly younger (11.2 ± 5.0 vs 38.4 ± 17.0; P = 0.005) and had a shorter time interval to valve replacement (11.0 ± 5.2 vs 30.1 ± 11.3; P = 0.03). The entire population showed a moderate correlation among energy expenditure, cardiac fatigue, perimeter of contraction and preoperative RV end-diastolic volume index. Both groups showed a reduction in all kinematic parameters after PVR, but those with end-diastolic volume >147 ml/m2 showed an unpredictable outcome. CONCLUSIONS Video kinematic evaluation provides insight into intraoperative RV recovery in patients with tetralogy of Fallot undergoing PVR. Accordingly, functional recovery can be expected in patients with preoperative end-diastolic volume <147 ml/m2.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Masateru Kawakubo ◽  
Yuzo Yamasaki ◽  
Daisuke Toyomura ◽  
Kenichiro Yamamura ◽  
Ichiro Sakamoto ◽  
...  

AbstractWe measured right ventricular (RV) strain by applying a novel postprocessing technique to conventional short-axis cine magnetic resonance imaging in the repaired tetralogy of Fallot (TOF) and investigated whether pulmonary valve replacement (PVR) changes the RV strain. Twenty-four patients with repaired TOF who underwent PVR and 16 healthy controls were enrolled. Global maximum and minimum principal strains (GPSmax, GPSmin) and global circumferential and longitudinal strains (GCS, GLS) were measured from short-axis cine images reconstructed radially along the long axis. Strain parameters before and after PVR were compared using paired t-tests. One-way ANOVA with Tukey post-hoc analysis was used for comparisons between the before and after PVR groups and the control group. There were no differences in strain parameters before and after PVR. The GPSmax before PVR was lower than that in the control group (P = 0.002). Before and after PVR, GCSs were higher and GLSs were lower than those in the control group (before and after GCSs: P = 0.002 for both, before and after GLSs: P < 0.0001 and P = 0.0003). RV strains from radially reconstructed short-axis cine images revealed unchanged myocardial motion after PVR. When compared to the control group, changes in GCS and GLS in TOF patients before and after PVR might be due to RV remodeling.