How to interpret the paediatric 12-lead ECG

Author(s):  
Paraskevi Mikrou ◽  
Pushpa Shivaram ◽  
Constantinos Kanaris

ECG interpretation is a core skill for any healthcare practitioner that looks after children. The article aims to educate the reader in basic interpretation of paediatric ECG in a succinct, interactive, organised manner in a way that it can be easily referenced and applied in everyday clinical practice. We include clinical examples as well as age and sex-related reference ranges for QT intervals, P-wave duration, Q-wave amplitude, QRS complex duration, R-wave and S-wave amplitude, R/S ratio and PR intervals.

2015 ◽  
pp. 5037-5045
Author(s):  
Claudia Guerrero S ◽  
Janeth Bolivar B ◽  
Piero Vargas-Pinto ◽  
Pedro Vargas-Pinto ◽  
Claudia Brieva-Rico

ABSTRACT Objective. To stablish the electrocardiographic parameters of individuals of the species Amazona ochrocephala, from the Unidad de Rescate y Rehabilitacion de Animales Silvestres at the Universidad Nacional de Colombia. Materials and methods. The electrocardiographic examination was performed under inhaled anesthesia with isoflurane. Leads I, II, III, aVL, aVR and aVF were measured. Results. Electrocardiographic parameters obtained in Lead II. P wave Duration: 0.015-0.044 s, P wave amplitude: 0.031 to 0.6 mv, R wave duration: 0.015-0.022 s, amplitude R: 0.034-0.038 mv, S wave Duration: 0.019- 0.042 s, amplitude S: 0.194-0.815 mv, T wave Duration: 0.025-0.064 s, T-wave amplitude: 0.010 to 0.5 mv, PQ Duration: 0.021-0.076 s, QRS Duration: 0.036-0.068 s, QT Duration: 0.070-0.015 s, RR Duration: 0.104-0.324 s, EEM: -111° to -80°, FC: 240-600 ppm. Conclusions. The results showed different values for amplitude and duration of the P, R and T waves in comparison to those obtained in other studies. However, they were similar for heart rate, MEA and duration of the PQ/R, QT and QRS segments.


2018 ◽  
Vol 7 (3.12) ◽  
pp. 632
Author(s):  
Manikandan K ◽  
Mohanasundaram K

With the advancement in the field of Electrocardiology (ECG), the acquisition of electrical activity of the heart plays an important role in the diagnosis of various cardiovascular diseases. In general, this activity of conduction is acquired using Standard 12 Lead ECG system. Recently, a Modified Limb Lead system has been developed to study the atrial electrical activity for the diagnosis of atrial arrhythmias. The present study is to derive the normal limits of female subjects using Modified Limb Lead (MLL) system. This study was evaluated in 59 female subjects 19.52 ± 1 (Mean ± S.D) and is primarily involved to study atrial potentials with the use of precordial and modified limb lead position. In sinus rhythm female subjects, the P wave amplitude was 33.06 ± 21.18 µV and the Ta wave amplitude was 20.72 ± 18.16 µV. The P wave duration was 94.22 ± 10.64 ms, the Ta wave duration was 85.51 ± 17.49 ms. The results show that modifications in the limb electrode placement have significant effect on amplitudes and PR segment which may be of great importance for the assessment of atrial potentials.  


2005 ◽  
Vol 38 (4) ◽  
pp. 36-37 ◽  
Author(s):  
Eunyoung Lee ◽  
Andrew D. Michaels ◽  
Dan Schindler ◽  
Barbara J. Drew

Author(s):  
Arya Bhardwaj ◽  
J. Sivaraman ◽  
S. Venkatesan

Objective: This study aims to characterize P and Ta wave of Modified Limb Lead (MLL) Electrocardiogram (ECG) in Normal Sinus Rhythm (NSR) and Atrioventricular Block (AVB). Methods: ECGs were recorded using MLL configuration from 100 NSR volunteers (mean age 31 years, 35 women) and 20 male AVB patients (mean age 72 years). Amplitudes and durations of P, Ta wave, and PTa Interval (PTaI) were measured, plotted, and analyzed for both the groups. Results: P-wave amplitudes were larger in AVB, and also P, Ta waves correlated significantly in both groups with higher correlation in AVB (NSR: [Formula: see text]; AVB: [Formula: see text]). Ta-wave duration ([Formula: see text] ms) was longer than P-wave duration ([Formula: see text] ms) in AVB patients and was opposite to P-wave polarity in all the leads. PP Interval (PPI) correlated significantly with P wave (NSR: [Formula: see text]; AVB: [Formula: see text]), Ta wave ([Formula: see text]; [Formula: see text]), PTaI ([Formula: see text]; [Formula: see text]), and corrected PTaI ([Formula: see text]; [Formula: see text]). Conclusion: P-wave right axis shift leads to the higher P-wave amplitude in AVB which may be due to the advancing age and atrial chamber enlargement. In NSR, the duration of observable Ta wave was longer than P wave, whereas in AVB, the Ta wave duration was 3–3.5 times longer than P wave.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Martinez-Selles ◽  
R Elosua ◽  
M Ibarrola ◽  
M De Andres ◽  
P Diez-Villanueva ◽  
...  

Abstract Background Advanced interatrial block (IAB), prolonged and bimodal P waves in surface ECG inferior leads, is an unrecognized surrogate of atrial dysfunction and a trigger of atrial dysrhythmias, mainly atrial fibrillation (AF). Our aim was to prospectively assess whether advanced IAB in sinus rhythm precedes AF and stroke in elderly outpatients with structural heart disease, a group not previously studied. Methods Prospective observational registry that included outpatients aged ≥70 years with structural heart disease and no previous diagnosis of AF. Patients were divided into three groups according to P-wave characteristics. Results Among 556 individuals, 223 had normal P-wave (40.1%), 196 partial IAB (35.3%), and 137 advanced IAB (24.6%). After a median follow-up of 694 days; 93 patients (16.7%) developed AF, 30 stroke (5.4%), and 34 died (6.1%). Advanced IAB was independently associated with AF (hazard ratio [HR] 2.9, 95% confidence interval [CI] 1.7–5.1, p<0.001), stroke (HR 3.8, 95% CI 1.4–10.7, p=0.010), and AF/stroke (HR 2.6, 95% CI 1.5–4.4, p=0.001). P-wave duration (ms) was independently associated with AF (HR 1.05, 95% CI 1.03–1.07, p<0.001), AF/stroke (HR 1.04, 95% CI 1.02–1.06, p<0.001), and mortality (HR 1.04, 95% CI 1.00–1.08, p=0.021). Conclusions The presence of advanced IAB in sinus rhythm is a risk factor for AF and stroke in an elderly population with structural heart disease and no previous diagnosis of AF. P-wave duration was also associated with all-cause mortality. Figure. Age- and sex-adjusted linear and non-linear association between P-wave duration (msec) and atrial fibrillation (A), stroke (B), and atrial fibrillation or stroke (C) risk. Results of a generalized additive model with spline smoothing functions and 4 degrees of freedom. Figure 1. Kaplan-Meyer curves of survival free of atrial fibrillation (A), stroke (B) and atrial fibrillation or stroke (C) in patients with normal P-wave, partial interatrial block (IAB) and advanced IAB. Funding Acknowledgement Type of funding source: None


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Relander ◽  
T Hellman ◽  
T Vasankari ◽  
I Nuotio ◽  
K.E.J Airaksinen ◽  
...  

Abstract Background Rhythm control using electrical cardioversion (CV) is a common treatment strategy for patients with symptomatic atrial fibrillation (AF). However, little is known about electrocardiographic (ECG) markers predicting CV failure and AF recurrence. Methods This study included 726 patients who underwent a CV for AF lasting >48h in a referral hospital. We analysed markers of atrial cardiomyopathy in post-CV sinus rhythm ECGs and compared them with CV failure and AF recurrence rates within 30 days after CV as well as their combination (ineffective CV). Of those with failed CV the most recent sinus rhythm ECG was used. Results CV was unsuccessful in 66 out of 726 patients (9.09%). Advanced interatrial block (IAB) defined as P-wave duration ≥120ms and biphasic morphology in inferior (II, III and aVF) leads (OR 3.96, 95%-CI 2.09–7.52, p<0.001) was an independent predictor for CV failure. Within 30 days after CV, AF recurred in 214 (32.4%) patients. Advanced IAB (OR 2.10, 95%-CI 1.19–3.72, p=0.011) was an independent predictor for AF recurrence. In total CV was ineffective (CV failure or AF recurrence) 280 of 726 times (38.6%). Advanced IAB (OR 2.72, 95%-CI 1.64–4.51, p<0.001) was an independent predictor for ineffective CV. Partial IAB categorized as P-wave duration ≥120ms with no biphasic morphology did not predict any end points. Conclusions Advanced IAB predicts CV inefficacy. This study identified ECG markers of atrial cardiomyopathy for clinical use in CV patient selection. Funding Acknowledgement Type of funding source: Foundation. Main funding source(s): This study research was funded by grants from the Finnish Medical Foundation, the Finnish Foundation for Cardiovascular Research, State Clinical Research Fund of Turku University Hospital, Turku, Finland, Finnish Cardiac Society, the Emil Aaltonen Foundation, and the Maud Kuistila Foundation.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
S Masood ◽  
M.M Azharuddin ◽  
S.M.K Ashraf ◽  
S Wahab

Abstract Introduction Around 25% of all ischaemic strokes have no known cause despite standard investigations. Most of these cases are suspected to have an embolic source for ischaemia, leading to the moniker of Embolic Stroke of Undetermined Source (ESUS). Recent studies suggest that abnormalities of the left atrium, in the form of atrial cardiopathy, can lead to increased risk of stroke even in the absence of atrial fibrillation (AF), which may be either as precursors to AF or as independent risk factors for the development of left atrial thrombus and subsequent stroke. Purpose The aim of this study was to measure LA electromechanical dissociation, LA volumes and P-wave dispersion as markers of atrial cardiopathy in patients with ESUS to determine whether atrial cardiopathy may be in the causal pathway of ESUS. Methods 28 patients presenting with ischaemic stroke and fulfilling the criteria for ESUS were enrolled into this cross-sectional, observational study. All patients had 24-hour Holter monitoring done to rule out the presence of AF. The control group consisted of 28 age- and gender-matched apparently healthy individuals. On ECG, P-wave Dispersion (PWD) was calculated by subtracting minimum P-wave duration from maximum P-wave duration. On echocardiography, time intervals from the beginning of P-wave to beginning of A' wave from the lateral mitral annulus in tissue doppler imaging was measured as the atrial electromechanical delay. LA volumes were recorded using the Modified Biplane Simpson's method. Statistical analysis was performed using student's t-test, chi-square test, and Pearson's test. Results Baseline demographic and laboratory characteristics were similar between the two groups. Increased PWD (34.14±9.89 ms vs. 27.32±8.95 ms; p=0.01), atrial electromechanical delay (73.32±16.31 ms vs. 63.63±13.59 ms; p=0.02) and LA volumes were observed in patients with ESUS as compared to controls. A significant correlation was also found between these parameters (p<0.01). Discussion According to the results of our study, PWD, atrial electromechanical delay and LA volumes may be novel predictors for ESUS. Atrial cardiopathy is a unique mechanism of thrombo-embolism in ESUS patients and our data establishes its association with ESUS. Further studies will be needed to shed more light on its role in the causality of stroke in the ESUS population. Measurement of electromechanical delay Funding Acknowledgement Type of funding source: None


Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S31-S32
Author(s):  
Michael Gardner ◽  
Shruti Bidani ◽  
Muzammil Khan ◽  
Jianhui Zhu ◽  
William W. Barrington ◽  
...  

2013 ◽  
Vol 6 (2) ◽  
pp. 287-293 ◽  
Author(s):  
Ken-ichi Maeno ◽  
Satoshi Kasagi ◽  
Azusa Ueda ◽  
Fusae Kawana ◽  
Sugao Ishiwata ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document