Biodegradeable temporising matrix use in a traumatic chest wound

2021 ◽  
Vol 14 (12) ◽  
pp. e246691
Author(s):  
Eliot Carrington-Windo ◽  
Sam Leong ◽  
Nader Ibrahim ◽  
Sophie Pope-Jones

The Welsh Centre for Burns and Plastic Surgery is responsible for a population of 10 million people in Wales and England. We describe the use of biodegradable temporising matrix (BTM) in a large traumatic chest wound in a 23-year-old woman. BTM is a synthetic dermal substitute and has been utilised to achieve soft tissue coverage in complex wounds. This wound was sustained after the patient fell from a tractor into a large silage rake, resulting in injuries to her chest and limbs. Following meticulous debridement, her resulting full thickness skin defect measured 30 × 30 cm extending from the sternal notch to the upper abdomen, with bone, muscle and breast tissue exposure. The central chest area is complex to reconstruct due to the contours of the breasts and tendency to contracture following skin graft reconstruction. We demonstrate the first reported use of BTM for breast reconstruction, as far as we are aware.

2019 ◽  
Vol 6 (6) ◽  
pp. 2041
Author(s):  
Gopalan G. ◽  
Dhanaraju S.

Background: Management of lower extremity trauma with bone and soft tissue injury is a challenging task with the aim of giving early recovery and durable good quality skin cover according to the skin defect and analyze various reconstructive options at various levels of injury. Our aim of the study is to analyze various reconstructive options for traumatic skin loss involving lower limbs especially knee and below knee, and analyze the incidence of age, sex and etiology of traumatic defects.Methods: Prospective study in our plastic surgery department in the period of 24 months, with all the cases of traumatic defects of leg and foot where included. All age and sex patients were included.Results: Most common cause for traumatic leg and foot defects are road traffic accidents followed by accidental fall and others, most commonly in males amounting 73%, children 10% and  females 17%, among the skin and soft tissue  defects upper and lower 1/3 leg defects are predominant. Among the soft tissue coverage split thickness skin graft dominating about 60% of cases, flaps 30% of cases, among the flaps 70% are fasciocutaneous flaps predominantly inferiorly based  and 30% are muscle and musculocutaneous flaps, among the muscle predominantly soleus muscle flap was used to cover the defect.Conclusions:Road traffic accidents dominating the cause for leg and foot defects , males are more commonly affected  and upper one third leg defects are predominant for soft tissue coverage split thickness skin graft are commonest procedures followed that cutaneous and muscle flaps. 


2018 ◽  
Vol 6 (1) ◽  
pp. 108 ◽  
Author(s):  
Girish Umashankar Thimmanahalli ◽  
Mahesh Kumar

Background: Platelet-Rich Plasma (PRP) is an autologous product derived from whole blood through the process of gradient density centrifugation. After skin graft reconstruction, the healing process is longer and may be difficult, depending on the wound site, skin defect size, and patient comorbidities. The potential value of PRP lies in its ability to incorporate high concentrations of platelet-derived growth factors into the skin graft. Since not all patients afford commercially available recombinant platelet rich plasma for skin graft, platelet extract from patient’s own blood is being used in this study to test and demonstrate the therapeutic role of PRP in skin graft. The aim of this randomized, prospective study is to compare the effectiveness of PRP in skin graft with conventional method like sutures, staplers or glue.Methods: The source of data were the patients admitted as inpatients for the management of wounds to the department of general surgery, JSS Hospital, Mysore from September 2016 to September 2018. Total of 60 patients were studied; 30 cases were randomly chosen for study with autologous platelet rich plasma and 30 cases received conventional methods like staples/sutures used to anchor the skin grafts in a control group.Results: Autologous PRP showed faster and better healing rates. With PRP study group instant graft adherence was seen in all cases. Hematoma, graft edema, discharge from graft site, frequency of dressings and duration of stay in hospital were significantly less in the PRP. There were no adverse effects or reactions seen with the use of autologous PRP among the study group.Conclusions: The combination of PRP with Split Thickness Skin Graft (STSG) significantly improved clinical outcomes and shortened the wound healing time. Therefore, this treatment combination could provide a way to heal skin after skin graft reconstruction with minimal recovery time. It is found to be highly beneficial in many aspects both to the patient and surgeon based on our results.


2021 ◽  
Vol 42 (Supplement_1) ◽  
pp. S123-S123
Author(s):  
Aldin Malkoc ◽  
David Wong

Abstract Introduction Advances in burn injury knowledge, critical care, and pharmacological developments have increased survival rates among extensive burn patients. Survival now dependents not just on skin coverage, but effective control of SIRS response, metabolic derangement, fluid loss and sepsis. Novel synthetic dermal substitutes create robustness, thickness, and pliability of the skin in addition to an improved aesthetic appearance while; point-of-care autologous skin cell harvesting enhances treatment by amplifying small split-thickness skin samples to produce an autologous skin cell suspension (ASCS) to cover a larger burn area. This study reports on two survivors with greater than 90% total body surface area full-thickness burns utilizing a combined treatment of a dermal substitute along with ASCS and traditional burn management strategies. Methods Chart review of two patients with >90% burns and inhalation injury after being trapped in a burning vehicle following a traffic collision occurred. Most of the burns in both patients were “leathery” and consistent with full thickness, sparing only the plantar and dorsal aspect of the feet and bilateral small areas of the hip in Patient 1. Patient 2 had fourth-degree burns in some areas of the chest and flank with only the bilateral groin regions and feet spared. The patients were treated with a multi-step process which included using allograft, dermal substitute, and ASCS with split-thickness skin grafts (STSG) in place of cultured epidermal autograft to achieve coverage of >90% burns with high meshed ratio. Results The dermal substitute was limited to deep burns that penetrated down to fat, muscle, and/or joints. Fluid loss was well controlled by the dermal substitute during initial resuscitation. Post reconstruction, areas covered with the dermal substitute and grafted with autogenous STSG with ASCS exhibited less hypertrophy and contracture bands. The elbow and knee joints showed minimal restriction with passive motion and good skin compliance, but contractures persisted in areas where 4th degree tendon and fascia thermal injury occurred. Areas that showed signs of infection were trimmed or unroofed and allowed to drain while maintaining the remainder of the dermal substitute. Conclusions The use of dermal substitutes and ASCS allowed the care team to achieve SIRS control, improved fluid management, enhanced skin coverage, and reduced hospitalization stay. The process experienced in these cases shows promise for future patients with extensive burns. Both patients were able to survive and show improvement during rehabilitation.


2021 ◽  
Vol 42 (Supplement_1) ◽  
pp. S195-S195
Author(s):  
Nicole M Kopari ◽  
Yazen Qumsiyeh

Abstract Introduction Complex wounds (CW) resulting from necrotizing soft tissue infections (NSTIs) and soft tissue traumatic injuries create unique challenges. Radical debridement is often the first step in management but can result in disfigurement with impaired function and compromised cosmesis. The standard of care at our institution for full-thickness burn injuries of similar complexity is widely meshed autografting with application of autologous skin cell suspension (ASCS). Our study is a case series reviewing outcomes using ASCS for CW from non-burn etiology. Methods A retrospective chart review from March 2019 through July 2020 was performed to evaluate the effectiveness of ASCS and widely meshed autografting in CW. Patients presenting with CW underwent serial excisions of devitalized tissue by acute care and burn surgeons. Dermal substitute utilization for wound preparation was at the discretion of the surgeon. Definitive wound closure was achieved using ASCS in combination with a widely meshed autograft. The wounds were covered with a non-adherent, non-absorbent, small pore primary dressing along with bismuth-impregnated, petroleum-based gauze or negative pressure wound therapy dependent on wound bed contour. Further padding with gauze was applied along with compressive dressing. Results In total, 8 patients with CW were included in this review. The mean age was 58 years (range 27-85) with an equal number of males and females. Wound etiology included NSTI (n=5), degloving injury (n=2), and traumatic amputation (n=1). The average wound size measured 1,300cm2 (range 300-3,000). 50% of the patients were treated with a dermal substitute and negative pressure wound therapy prior to ASCS and autograft placement. 7 of 8 patients received split-thickness skin grafting in the ratio of 3:1 with one patient grafted at a 2:1 expansion. 7 of the 8 patients had >90% wound closure within 8-10 days of ASCS and autograft application. One patient had significant graft failure after removing surgical dressings and autograft in the early post-operative period secondary to dementia. One patient expired during the follow-up period secondary to medical comorbidities. The 6 remaining patients had durable wound closure and acceptable cosmetic outcome. All patients were discharged within 10 days of ASCS application with 4 patients discharging home and 4 patients discharging to an acute inpatient rehabilitation. Conclusions This study is the first case series to review ASCS in combination with widely meshed skin grafts in the management of CW from a non-burn etiology. Durable, timely wound closure and an acceptable cosmetic outcome was achieved in these often-challenging CW.


2017 ◽  
Vol 16 (3) ◽  
pp. 212-216
Author(s):  
Nor Hazla Mohamed Haflah ◽  
Min Hwei Ng ◽  
Mohd Heikal Mohd Yunus ◽  
Amaramalar Selvee Naicker ◽  
Ohnmar Htwe ◽  
...  

Open fracture Gustilo-Anderson grade IIIC is associated with higher risk of infection and problems with soft tissue coverage. Various methods have been used for soft tissue coverage in open fractures with large skin defect. We report a case of a patient who had grade IIIC open fracture of the tibia with posterior tibial artery injury. The patient underwent external fixation and reduction. Because of potential compartment syndrome after vascular repair, fasciotomy of the posterior compartment was performed. This wound, however, became infected and because of further debridement, gave rise to a large skin defect. A tissue engineered skin construct, MyDermTM was employed to cover this large defect. Complete wound closure was achieved 35 days postimplantation. The patient then underwent plating of the tibia for nonunion with no adverse effect to the grafted site. The tibia eventually healed 5 months postplating, and the cosmetic appearance of the newly formed skin was satisfactory.


2018 ◽  
pp. bcr-2018-226181
Author(s):  
Felicity Page ◽  
Krupali Patel ◽  
Wayne Jaffe

We present a challenging case of imminent metallic implant extrusion in a Paralympic athlete managed with a single-stage procedure using ‘Integra’ dermal substitute. The patient had hereditary spastic paraparesis, for which a baclofen pump delivering intrathecal medication was vital in the management of his condition. The device had been most recently implanted into the thigh after previous complications. Integra provided robust soft-tissue coverage over the implanted baclofen pump in the thigh. Different operative management strategies were considered but the use of Integra was felt to offer the least morbidity and a quick recovery. The patient was able to successfully compete in a Paralympic canoeing qualifying event the week following surgery and achieve medal success. To the authors’ knowledge, this is first case in which Integra has been used in such circumstances.


2013 ◽  
Vol 40 (1) ◽  
pp. 11 ◽  
Author(s):  
Hyunji Kim ◽  
Daegu Son ◽  
Tae Hyun Choi ◽  
Samhyun Jung ◽  
Sunyoung Kwon ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document