Effect of non-fat dry milk on recovery of staphylococcal thermonuclease from foods

1979 ◽  
Vol 25 (1) ◽  
pp. 44-46 ◽  
Author(s):  
C. E. Park ◽  
H. B. El Derea ◽  
M. K. Rayman

Modification of the method of Tatini et al. (1976) by addition of non-fat dry milk (NFDM) to food samples and subsequent acid precipitation at pH 3.8 enhanced the recovery of staphylococcal thermonuclease (TNase) from most of 37 foods tested. The modified TNase assay method allowed detection of 10 ng (0.002 units) of the enzyme per gram of each of the following foods: ground beef, boiled egg products, whey powder, fruit-containing yogurt, dressings and spreads, potato and egg salads, and pastas, all of which gave false-negative results without NFDM.

1979 ◽  
Vol 42 (2) ◽  
pp. 153-157 ◽  
Author(s):  
J. Y. D'AOUST ◽  
C. MAISHMENT

The efficacy of Clausen, EE, Eugon, GN, Tergitol 7, lactose and nutrient broths as Salmonella preenrichment media was evaluated using 165 food samples with an incident contamination level ranging from 1.5 to 460 salmonellae/100 g. Replicate food samples (100 g) were preenriched in each of seven media (900 ml) for 6 h and 24 h at 35 C; various amounts (10, 1.0 and 0.1 ml) of preenriched cultures were selectively enriched in tetrathionate brilliant green (43 C) and selenite cystine (35 C) broths and plated on bismuth sulfite and brilliant green sulfa agars. Short (6 h) and 24-h preenrichment conditions resulted in 26 (16%) and 8 (5%) false negative results, respectively. Recovery of Salmonella from 6-h but not 24-h preenrichment cultures also varied directly with the portion of culture inoculated into selective enrichment broths. None of the preenrichment media tested performed satisfactorily at 6 h of incubation where levels of recovery ranged from 32 to 62%; at 24 h, good recovery was obtained with all media (95 to 100%) except EE broth (74%). The incidence of competitive flora was significantly higher on selenite + brilliant green sulfa than on tetrathionate + bismuth sulfite; transfer volumes (10 and 1.0 ml) and preenrichment media did not contribute significantly to the presence of non-salmonellae on plating media. Characteristics of preenrichment media were found to be less critical than preenrichment incubation time for effective recovery of Salmonella in foods and feed ingredients. The use of 1.0- rather than 10-ml preenrichment transfer volume is indicated because it proved to be completely reliable under our experimental conditions and reduced the cost of analyses.


1982 ◽  
Vol 45 (3) ◽  
pp. 249-252 ◽  
Author(s):  
J.-Y. D'AOUST ◽  
C. MAISHMENT ◽  
P. STOTLAND ◽  
A. BOVILLE

Inhibitory concentrations of 8 surfactants were determined for Salmonella typhimurium and Salmonella enteritidis. Pure culture work resulted in the exclusion of Tween 20, Teepol 610 and Brij 35 and retention of Tergitol-7 (T-7), Tween 80 (TW 80), Triton X-100 (TX), Myrj 52S (M), and Arlacel 80 + Tween 60 (AT) for a study on the quantitative recovery of Salmonella in 45 naturally contaminated fatty foods. Replicate food samples (100 g) were preenriched overnight at 35 C in nutrient broth supplemented with 3%(w/v) surfactant except AT (10%). Serial dilutions of preenrichment cultures were selectively enriched overnight in tetrathionate brilliant green (43 C) and selenite cystine (35 C) broths and streaked on bismuth sulfite and brilliant green sulfa agar media. Recovery with all test surfactants was comparable to that obtained with nutrient broth controls; of 270 preenrichment cultures tested, only 7 false-negative results attributable to TX (3), AT (2), M (1), and nutrient broth control (1) were obtained. None of the surfactants consistently yielded greater populations of Salmonella for given foods or food categories; median counts for preenrichment cultures were 104–105 salmonellae/ml for low and high moisture foods and 106–107 salmonellae/ml for animal feeds. These results suggest that use of surfactants to facilitate detection of Salmonella in fatty foods is not warranted.


1986 ◽  
Vol 49 (2) ◽  
pp. 92-98 ◽  
Author(s):  
GEORGE F. IBRAHIM ◽  
MARY J. LYONS ◽  
RETA A. WALKER ◽  
GRAHAM H. FLEET

A standard cultural method, radioimmunometric (RIMA) and enzyme immunometric (EIMA) assays were compared for detection of salmonellae in 235 food samples. The immunoassays used titanous hydroxide as the solid-phase, commercial Spicer-Edwards salmonella polyvalent H antisera (SEA) or pooled antisera produced against 10 salmonella flagellins (PFA). Nineteen food samples were positive for Salmonella by the standard cultural method. These as well as one additional sample were also positive for Salmonella by RIMA and EIMA. No false-negative results were obtained from the immunoassays using PFA, whereas two false-negative results were observed when SEA was used. The incidence of false-positive results when SEA and PFA were used were, respectively, 3.0 and 0.9% with RIMA and 2.6 and 0.9% with EIMA. The immunoassays were also able to detect 77 Salmonella serotypes when grown alone or in association with other species of Enterobacteriaceae, in mannitol selenite cystine broth. Both immunoassays performed reliably on enrichment cultures stored under refrigeration for up to 9 d. Also, of 6 non-motile salmonellae, 5 were detectable by the immunoassays. The immunoassays were simple, rapid and cost-efficient.


2002 ◽  
Vol 65 (10) ◽  
pp. 1656-1659 ◽  
Author(s):  
KUANG-SHENG YEH ◽  
CHIN-EN TSAI ◽  
SHIH-PING CHEN ◽  
CHAO-WEI LIAO

VIDAS Salmonella (VIDAS-SLM) is an automated system that uses the enzyme-linked fluorescent assay method to detect Salmonella species. This study evaluated the efficacy of the VIDAS-SLM method in detecting Salmonella species in pork carcass sponge samples gathered from 10 slaughter plants in Taiwan. Two hundred fifty-seven pork carcass sponge samples were screened by the VIDAS-SLM method and by the culture method in parallel. While 18 sponge samples were found to test positive by both methods, the VIDAS-SLM method detected four additional positive samples for which the culture method failed to recover Salmonella. The specificity of the VIDAS-SLM method was found to be 0.98, and its sensitivity was 1.0, since no false-negative results occurred. Artificially inoculated Salmonella at concentrations as low as 5.0 × 100 CFU/ml was detected in the heat-inactivated sponge sample in the presence or absence of 5.0 × 104 CFU of Citrobacter freundii per ml. Thus, the VIDAS-SLM method is a rapid screening method and a potential alternative to the time- and labor-intensive culture method.


2020 ◽  
Vol 22 (1) ◽  
Author(s):  
Sarah L. Tansley ◽  
◽  
Julia Snowball ◽  
John D. Pauling ◽  
Anya Lissina ◽  
...  

Abstract Background A myositis-specific autoantibody can now be identified in the majority of patients with myositis. They identify homogeneous patient subgroups and are key tools in developing a personalized approach to disease management. There is substantial clinical interest in exploiting myositis autoantibodies as biomarkers, and consequently, a large number of commercial assays have been developed for their detection. These assays are already in widespread clinical use. In order to better understand perceived concerns from the international myositis community in relation to the reliability of these assays and how they are being used, we conducted a survey of international myositis experts, all of whom were members of the International Myositis Assessment and Clinical Studies group. Results We collected data on the types of assay used, manufacturers, and the nature of the report provided by different laboratories and received 111 complete responses. Respondents also provided information on how they used the different assays, their confidence in the results, and how this influenced their clinical practice. Enzyme immunoassay/ELISA was the most popular assay method used worldwide followed by line blot. Line blot was the most popular method used in Europe. Despite concerns from over 80% of respondents regarding false-positive and false-negative results with the assay used by their laboratory, over 80% reported that the identification of a myositis autoantibody influenced their diagnostic confidence, the information they provided to a patient, and their recommended treatment. Conclusions In spite of ongoing concerns from the majority of users regarding the reliability of the results, myositis-specific autoantibody testing, using commercial immunoassays, is being used globally to inform clinical decision-making. These findings highlight the need for urgent guidance on the use of myositis autoantibody testing and on the interpretation of results. Knowledge of the reliability of currently available assays is essential given the importance already placed on myositis-specific autoantibodies as clinical decision-making tools.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


2020 ◽  
Vol 13 (1) ◽  
pp. 413-414 ◽  
Author(s):  
Mohamed Farouk Allam

Due to the international spread of COVID-19, the difficulty of collecting nasopharyngeal swab specimen from all suspected patients, the costs of RT-PCR and CT, and the false negative results of RT-PCR assay in 41% of COVID-19 patients, a scoring system is needed to classify the suspected patients in order to determine the need for follow-up, home isolation, quarantine or the conduction of further investigations. A scoring system is proposed as a diagnostic tool for suspected patients. It includes Epidemiological Evidence of Exposure, Clinical Symptoms and Signs, and Investigations (if available). This scoring system is simple, could be calculated in a few minutes, and incorporates the main possible data/findings of any patient.


2020 ◽  
Vol 18 ◽  
Author(s):  
Pegah Shakib ◽  
Mohammad Reza Zolfaghari

Background: Conventional laboratory culture-based methods for diagnosis of Streptococcus pneumoniae are time-consuming and yield false negative results. Molecular methods including real-time (RT)-PCR rapid methods and conventional PCR due to higher sensitivity and accuracy have been replaced instead traditional culture assay. The aim of the current study was to evaluate lytA gene for detection of Streptococcus pneumoniae in the cerebrospinal fluid of human patients with meningitis using real-time PCR assay. Material and Methods: In this cross-sectional study, a total of 30 clinical specimens were collected from patients in a period from September to December 2018. In order to evaluate the presence of lytA gene, conventional and real-time PCR methods were used without culture. Results: From 30 sputum samples five (16.66%) isolates were identified as S. pneumoniae by lytA PCR and sequencing. Discussion: In this research, an accurate and rapid real-time PCR method was used, which is based on lytA gene for diagnosis of bacteria so that it can be diagnosed. Based on the sequencing results, the sensitivity for detection of lytA gene was 100% (5/5).


Sign in / Sign up

Export Citation Format

Share Document