The influence of facing stiffness on the performance of two geosynthetic reinforced soil retaining walls

2006 ◽  
Vol 43 (12) ◽  
pp. 1225-1237 ◽  
Author(s):  
Richard J Bathurst ◽  
Nicholas Vlachopoulos ◽  
Dave L Walters ◽  
Peter G Burgess ◽  
Tony M Allen

Current limit equilibrium-based design methods for the internal stability design of geosynthetic reinforced soil walls in North America are based on the American Association of State Highway and Transportation Officials (AASHTO) Simplified Method. A deficiency of this approach is that the influence of the facing type on reinforcement loads is not considered. This paper reports the results of two instrumented full-scale walls constructed in a large test facility at the Royal Military College of Canada. The walls were nominally identical except one wall was constructed with a stiff face and the other with a flexible wrapped face. The peak reinforcement loads in the flexible wall were about three and a half times greater than the stiff-face wall at the end of construction and about two times greater at the end of surcharging. The stiff-face wall analysis using the Simplified Method gave a maximum reinforcement load value that was one and a half times greater than the measured value at the end of construction. Furthermore, the surcharge pressure required to reach the creep-limited strength of the reinforcement was about two times greater than the predicted value. The results demonstrate quantitatively that a stiff facing in a reinforced soil wall is a structural component that can lead to significant reductions in reinforcement loads compared to flexible facing systems.Key words: geosynthetics, retaining walls, reinforced soil, wrapped face, structural facings.

2021 ◽  
Vol 17 ◽  
pp. 13-20
Author(s):  
Ananya Srivastava ◽  
Sagar Jaiswal ◽  
Vinay Bhushan Chauhan

This study intends to examine the behavior of a GRS wall with static footing loading above it, while varying the positions of the footing. For the study of behavior of such complex structure, finite element modeling is handy and enables to look into the various stress/strain developed in the numerical model. In view of the above, a series of finite element (FEM) simulations using a software (Optum G2) is performed for the analysis of the GRS wall. The governing parameters, such as footing width (B), reinforcement length (L), offset distance (D), are evaluated and the effect of these factors on the ultimate bearing capacity (q) and settlement (s) of the footing is presented in this study. The results depict that the settlement of the footing substantially reduced in the range of 36% and its ultimate bearing capacity is increased to 42% more than the conventional retaining walls.


1999 ◽  
Vol 6 (5) ◽  
pp. 383-416 ◽  
Author(s):  
S.C.R. Lo ◽  
J. Bosler ◽  
M. Gopalan

Sign in / Sign up

Export Citation Format

Share Document