OUTCOMES OF FOUR-CORNER ARTHRODESIS USING THE HUBCAPTM CIRCULAR PLATE

Hand Surgery ◽  
2013 ◽  
Vol 18 (02) ◽  
pp. 215-220 ◽  
Author(s):  
Sameer K. Khan ◽  
Syed M. Ali ◽  
Andrew McKee ◽  
Jonathan W. M. Jones

We present results of four-corner carpal arthrodesis with the Acumed® HubcapTM circular plate performed at our unit. Eight patients underwent eight procedures over five years, for scapholunate advanced collapse (five wrists) and scaphoid non-union advanced collapse (three wrists). Outcomes included range of motion, quickDASH scores, and visual analogue scores for satisfaction. At final follow-up, mean flexion-extension arc was 56°, mean radial-ulnar deviation 29° and mean quickDASH score was 23/100. Mean score for satisfaction was 7.7/10 (77%). Seven out of eight (87.5%) patients said they would have it done again, and would also recommend it to others. Radiological union was achieved in all cases. One screw broke in one arthrodesis without causing symptoms. The functional outcomes with our use of the HubcapTM are comparable to those reported in literature to date with other circular plates (e.g. Spider plate). There were no non-unions, which is the main reported complication with these plates.

2009 ◽  
Vol 34 (2) ◽  
pp. 252-255 ◽  
Author(s):  
E. A. VAN AMERONGEN ◽  
A. H. SCHUURMAN

Range of motion, pain, consolidation and complications were evaluated for nine patients who underwent four-corner arthrodesis using the Quad Memory Staple (QMS) at a mean follow-up of 44 months. The mean pre-operative range of motion was 50° extension, 62° flexion, 9° radial deviation and 24° ulnar deviation. The postoperative range of motion was similar to previous studies at 32° extension, 31° flexion, 15° radial deviation and 20° ulnar deviation. The grip strength was 28 kg pre-operatively and 26 kg postoperatively. The mean pain score improved from 41 to 23 and the Disabilities of Arm, Shoulder, and Hand (DASH) score from 24 to 20. Non-union, haematoma and wound infection were not seen and eventually all four-corner fusions were consolidated. The main advantages of the QMS are its compressive property and the simple fixation technique. It gives good stability, enables early rehabilitation and avoids the risks of pin fixation methods.


2017 ◽  
Vol 2 (3) ◽  
pp. 2473011417S0001 ◽  
Author(s):  
Alexej Barg ◽  
Charles Saltzman

Category: Ankle, Ankle Arthritis Introduction/Purpose: In the last two decades, total ankle replacement (TAR) has gained more acceptance as a treatment option in patients with end-stage ankle osteoarthritis. However, there is a lack of literature on TAR using a lateral transfibular approach. Therefore, we sought to report early clinical and radiographic results of a patient cohort treated with TAR using a lateral transfibular approach by a single surgeon. Methods: Fifty-five primary total ankle arthroplasties using the Zimmer trabecular metal implant were performed in 54 patients (29 men and 25 women; mean age, 67.0 years) from October 2012 to December 2014. Clinical assessment including pain evaluation and measurement of ankle range of motion was done preoperatively and at the latest follow-up. Weight-bearing radiographs were used to determine the angular alignment of the tibial and talar components and to analyze the bone-implant interface. Intraoperative and postoperative complications, revision surgeries, and failures were evaluated. Results: Implant survival was 93% at 36 months follow-up. There were 3 revisions of a tibial component due to aseptic loosening. In 10 of 55 procedures, a secondary procedure was performed during follow-up. Mean follow-up duration was 26.6 ± 4.2 months. No delayed union or non-union was observed for fibula healing. The average VAS pain score decreased significantly from 7.9 ± 1.3 to 0.8 ± 1.2. The average total range of motion increased significantly from 22.9° ± 11.8° to 40.2° ± 11.8°. Conclusion: Early results of Zimmer trabecular metal total ankle replacement demonstrated improved patient-reported outcomes and increased ankle motion at a minimum follow-up of one year. In the first 55 consecutive cases, the fibular osteotomy required for access to the ankle healed without complications. Painful early loosening requiring revision due to lack of bony ingrowth was seen in 3 of 55 cases.


2018 ◽  
Vol 07 (04) ◽  
pp. 324-330
Author(s):  
Rémy Coulomb ◽  
Pascal Kouyoumdjian ◽  
Olivier Mares ◽  
Benjamin Degeorge

Purpose We retrospectively evaluated the results of all arthroscopic dorsal scapholunate (SL) capsuloplasty without pinning in patients presenting predynamic instability and dorsal capsuloscapholunate septum lesions on arthro–computed tomography scan after failed medical treatment. Materials and Methods Fifteen patients, mean age 34.3 years, underwent all arthroscopically assisted dorsal capsuloplasty. Patients were assessed preoperatively and postoperatively by a clinical (pain, Watson's test, range of motion, and strength), functional (quick disabilities of the arm, shoulder, and hand), patient-rated wrist evaluation, and Mayo wrist score scores), and radiological (SL gap and dorsal intercalated segmental instability [DISI]) examination. SL tears were evaluated during surgery by European Wrist Arthroscopy Society (EWAS) classification. Results The mean follow-up period was 20.2 months (range, 12–41). Preoperatively, positive Watson's test was noted in all cases. DISI deformity was noted in three cases without any SL gap. The SL instability was graded EWAS IIIB (n = 8) or EWAS IIIC (n = 7). Postoperatively, positive Watson's test was noted in only one case. Activity pain decreased from 7.8 preoperatively to 2.4 postoperatively. Range of motion in flexion–extension increased from 92.9 degrees preoperatively to 126.2 degrees postoperatively. Grip strength increased from 24.2 preoperatively to 38.2 postoperatively. At final follow-up, range of motion in flexion–extension and grip strength were estimated at 87 and 91% compared with contralateral side, respectively. All functional scores were significantly improved at the last follow-up. No radiographic SL gapping in grip views or DISI deformity was noted. Discussion Cadaveric studies demonstrated that the dorsal portion of SL ligament is critical for the stability of the SL complex. The entire arthroscopic SL capsuloplasty technique provides reliable results for pain relief, avoiding postoperative stiffness associated with open procedures. It is an alternative technique for patients with predynamic SL instability after failure of medical management and shall not prelude the resort to any further open procedure. Level of Evidence This is a level IV, case series.


Author(s):  
Sebastian Undurraga ◽  
Kendrick Au ◽  
Johanna Dobransky ◽  
Braden Gammon

Abstract Background/Purpose Scaphoid excision and partial wrist fusion is used for the treatment of scapholunate advanced collapse/scaphoid nonunion advanced collapse wrist arthritis. The purpose of this study was to report midterm functional and radiographic outcomes in a series of patients who underwent bicolumnar fusion of the lunocapitate and triquetrohamate joints using retrograde headless screws. Methods Twenty-three consecutive patients (25 wrists) underwent surgery with this technique from January 2014 to May 2017 with a minimum follow-up of 1 year. Assessment consisted of range of motion, grip, and pinch strength. Patient-reported outcome measures included disabilities of the arm, shoulder, and hand (DASH) and patient-rated wrist evaluation (PRWE) scores. Fusion rates and the radiolunate joint were evaluated radiographically. The relationship between wrist range of motion and midcarpal fusion angle (neutral position vs. extended capitolunate fusion angle > 20 degrees) was analyzed. Results Average follow-up was 18 months. Mean wrist extension was 41 degrees, flexion 36 degrees, and radial-ulnar deviation arc was 43 degrees. Grip strength was 39 kg and pinch 9 kg. Residual pain for activities of daily living was 1.6 (visual analog scale). The mean DASH and PRWE scores were 19 ± 16 and 28 ± 18, respectively. Patients with an extended capitolunate fusion angle trended toward more wrist extension but this did not reach statistical significance (p = 0.17). Conclusions With retrograde headless compression screws, the proximal articular surface of the lunate is not violated, preserving the residual load-bearing articulation. Patients maintained a functional flexion–extension arc of motion with grip-pinch strength close to normal. Capitolunate fusion angle greater than 20 degrees may provide more wrist extension but further studies are needed to demonstrate this. Level of Evidence This is a Level IV study.


2020 ◽  
Vol 8 (9_suppl7) ◽  
pp. 2325967120S0053
Author(s):  
Shashank Agarwal ◽  
Inder Pawar ◽  
Anil Kumar ◽  
Anjul Verma ◽  
Pawan Kumar

Introduction: Managing distal femur non-union can be a struggle for any orthopedician as it brings along many perplexities which may not lead to satisfactory patient outcome. The target in these cases should be to reduce the morbidity and allow early rehabilitation of the patient and to accomplish this, megaprostheses can be a feasible option. The orthodox use of megaprostheses is in the musculo-skeletal oncologic surgeries but its use can be extended to traumatic etiologies. These can be offered as a single stage definite procedure in patients who have already undergone several previous surgeries. Here we report a series of four cases of persistent non-union of distal femur treated with megaprostheses and recommend this modality for achieving the desired goal but the indication should be meticulously selected. Hypotheses: Megaprosthesis as a definitive treatment option in persistent distal femur non-union and prevention of repeated surgical intervention. Methods: Four cases of persistent distal femur nonunion with failed osteosynthesis were selected who were initially treated with a distal femur locking plate. Results were assessed in terms of range of motion, limb length discrepancy, knee society score and osteointegration of the components. Results: The mean age of the patients at the time of DFEPR was 49 years (42-55). The mean follow up of patients was for approximately 2 years, with the longest follow up being 3.5 years for the first operated case of the series. The range of motion was from full extension to about 105 degrees of flexion with two patients having an extension lag of 10 degrees. Patients were ambulatory without support. Postoperatively, the mean knee society score was 83 (78–88) at last follow-up as compared to 29 (21-36) in the pre-operative period. No case of infection or loosening was reported. There was 1 cm of shortening in one patient in the operated limb which was compensated by giving shoe raise. Good osseointegration of the megaprosthesis was revealed on both anteroposterior and lateral radiographs. Conclusion: Although there are very limited studies on the use of megaprosthesis for traumatic cases, it can be considered as an alternative when we are left with only arthrodesis or amputation as the final option. Despite the operative challenges, there is marked improvement in pain and functional capacity as experienced by these severely limited patients, which are the hallmarks of a successful salvage. The use of distal femur mega-prosthesis is a novel acumen in cases, where bone stock at the fracture site at distal end of femur is so severely compromised that traditional revision osteosynthesis would not provide stable and durable fixation. The indications for this surgery must be rigorously selected and should only complement osteosynthesis procedures, which remain the reference treatment option.


2019 ◽  
Vol 09 (02) ◽  
pp. 136-140
Author(s):  
C. A. Selles ◽  
M. A. M. Mulders ◽  
G. R. Roukema ◽  
C. H. van der Vlies ◽  
B. I. Cleffken ◽  
...  

Abstract Background Closed reduction and cast immobilization of displaced distal radius fractures carries the risk of secondary displacement, which could result in a symptomatic malunion. In patients with a symptomatic malunion, a corrective osteotomy can be performed to improve pain and functional impairment of the wrist joint. Objective The aim of this study was to assess the functional outcomes of children who underwent a corrective osteotomy due to a symptomatic malunion of the distal radius. Methods Between 2009 and 2016, all consecutive corrective osteotomies of the distal radius of patients younger than 18 years were reviewed. The primary outcome was functional outcome assessed with the ABILHAND-Kids score. Secondary outcomes were QuickDASH (Quick Disabilities of Arm, Shoulder, and Hand) score, range of motion, complications, and radiological outcomes. Results A total of 13 patients with a median age of 13 years (interquartile range [IQR]: 12.5–16) were included. The median time to follow-up was 31 months (IQR: 26–51). The median ABILHAND-Kids score was 42 (range: 37–42), and the median QuickDASH was 0 (range: 0–39). Range of motion did not differ significantly between the injured and the uninjured sides for all parameters. One patient had a nonunion requiring additional operative treatment. The postoperative radiological parameters showed an improvement of radial inclination, radial height, ulnar variance, dorsal tilt, and dorsal tilt. Conclusion Corrective osteotomy for children is an effective method for treating symptomatic malunions of the distal radius. Level of Evidence This is a Level IV study.


2019 ◽  
Vol 30 (6) ◽  
pp. 793-798 ◽  
Author(s):  
Kaushik Bhowmick ◽  
Thomas Matthai ◽  
Perumal Ramaswamy JVC Boopalan ◽  
Thilak S Jepegnanam

Aim: Intertrochanteric fractures account for almost 50% of hip fractures.Nonunion and malunion of these fractures are relatively uncommon. This study reviews the outcome of 31 cases of intertrochanteric fracture failures. An algorithm for the management of these injuries is also proposed. Methods: 19 patients with intertrochanteric malunion and 12 patients with non-union were included in this study. Treatment of these injuries was initiated according to the algorithm proposed in this study. Treatment outcomes were evaluated by assessing union, pre and postoperative shortening and HSA (head-shaft angle). Functional outcomes were assessed by the Parker mobility scale and presence or absence of pain. Results: All the patients with intertrochanteric malunion with follow-up had united. The postoperative shortening in all patients were ⩽2.5 cms. Patients having intertrochanteric nonunion with follow-up, who underwent internal fixation had united with an acceptable Parker mobility scale score, except in 1 patient who sustained an ipsilateral distal femur fracture. The average HSA correction obtained was 21° (range 3–60°). Conclusion: The algorithm proposed in this study helps streamline the treatment according to each case scenario.It helps in planning and managing patients with intertrochanteric fracture failures.


2010 ◽  
Vol 35 (9) ◽  
pp. 740-745 ◽  
Author(s):  
M.J. Berkhout ◽  
M.N. Shaw ◽  
L.J. Berglund ◽  
K.N. An ◽  
R.A. Berger ◽  
...  

Radioscapholunate arthrodesis is a salvage procedure indicated for osteoarthritis of the radiocarpal joint involving the lunate facet of the radius. This cadaver study examines changes in wrist motion resulting from radioscapholunate arthrodesis, and the effects of surgical techniques to improve the range of motion. Simulated radioscapholunate arthrodesis, distal scaphoidectomy and triquetrectomy were carried out sequentially on six cadaver forearms and measurements (maximum flexion/extension and radial/ulnar deviation) were taken in the intact situation and after each surgical step using a magnetic tracking device. Radioscapholunate arthrodesis diminishes the amplitudes of movements of the wrist in all directions, but range of motion in the radioscapholunate fused wrist improves after scaphoidectomy and improves further after triquetrectomy (88% of original flexion/extension and 98% of original radial/ulnar deviation). Radioscapholunate arthrodesis causes a significant change in kinematics between the hamate and the triquetrum in flexion/extension.


2005 ◽  
Vol 30 (4) ◽  
pp. 365-368 ◽  
Author(s):  
P. H. J. BULLENS ◽  
M. DRIESPRONG ◽  
H. LACROIX ◽  
J. VEGTER

Thirty-three symptomatic scaphoid non-unions were treated by a simple, minimally invasive procedure using a percutaneous autologous corticocancellous bone graft. After an average follow-up of 3.5 years, union was observed in 29 cases. These patients had no, or mild, pain at work and an almost normal range of motion and grip strength. No progression to osteoarthritis was observed.


2018 ◽  
Vol 11 (5) ◽  
pp. 359-371 ◽  
Author(s):  
David Cinats ◽  
Aaron J Bois ◽  
Kevin A Hildebrand

Background The Latitude total elbow arthroplasty (TEA) is an implant with limited published data on its performance and outcomes. The aim of this study was to report the short-term outcomes of the Latitude TEA as well as to describe the radiographic outcomes and complications. Methods The Latitude was implanted in 20 patients (23 elbows) in a linked configuration. Patients were recalled to clinic for the assessment of their range-of-motion and compared to preoperative values. Administration of functional outcome measures was also performed. Results Mean follow-up was 4.7 years (range, 1 to 7.5 years) with four elbows requiring revision. The flexion–extension arc improved from 86.6 to 101.3 (range, 76 to 126) postoperatively (p = 0.04). The average Disabilities of the Arm, Shoulder, and Hand score was 28.1 (range, 5.8 to 50.4) and the average Mayo Elbow Performance Score was 89.6 (range, 76 to 100), with 83% of elbows scoring in the good or excellent range. Radiolucencies were detected in 60% of patients and 31% of these lucencies progressed in size at the time of follow-up. Conclusions The Latitude prosthesis provides patients with favorable clinical outcomes with improvements in their range-of-motion and a complication rate comparable to other elbow arthroplasty implants.