SIMULATION ON THE PERFORMANCE OF CARBON DIOXIDE AND HYDROCARBON HEAT PUMPS FOR MODERATE TO HIGH TEMPERATURE HEATING

2014 ◽  
Vol 22 (01) ◽  
pp. 1450001 ◽  
Author(s):  
YOUNG-JIN BAIK ◽  
MINSUNG KIM ◽  
HO-SANG RA

In order to compare the performance of the carbon dioxide, propane and isobutane heat pumps for moderate to high temperature heating, the three heat pump cycles were optimized using a simulation method. To fairly compare the performance of the cycles by using different working fluids, each cycle was optimized from the viewpoint of heating COP by two design parameters. The first is the gas cooler (or condenser) exit temperature and the other is the ratio of the overall heat conductance of the gas cooler to the combined overall heat conductance of the gas cooler and the evaporator. The inlet and outlet temperatures of secondary fluid of the gas cooler (or condenser) were fixed at 40/90°C and 40/150°C. The heat source inlet temperature was fixed at 10°C. The flow rates of both the heat source and the heat sink were also fixed. The results shows that the hydrocarbon heat pumps have 11–17% higher heating COP than carbon dioxide heat pump under the simulation conditions considered in the present study. However, for a high temperature heating, even though the isobutane heat pump shows the best performance, the carbon dioxide heat pump looks promising due to hydrocarbon heat pumps' high compression ratio.

2012 ◽  
Vol 49 ◽  
pp. 294-299 ◽  
Author(s):  
Dragi Lj. Antonijević ◽  
Dimitrije J. Manić ◽  
Mirko S. Komatina ◽  
Nedžad R. Rudonja

2020 ◽  
Vol 66 (11) ◽  
pp. 677-683
Author(s):  
Nedžad Rudonja ◽  
Milan Gojak ◽  
Ivan Zlatanović ◽  
Ružica Todorović

In this article is presented a thermodynamic analysis of a cascade heat pump system designed for using in high-temperature heating systems. The own thermodynamic model was built by using properties of working fluids from the CoolProp base. The cascade heat pump was designed to use ambient air as heat source with temperature t_amb= –20 °C and for heating water in the high-temperature heating system up to 70 °C. The projected heating capacity of the cascade heat pump was 100 kW. The coefficient of performance (COP) of the cascade heat pump system due to use of different working mediums combinations in cycles of the cascade heat pump was investigated. For the best combination of working fluids (mediums) sub-cooling, super-heating, pressure loss in compressor’s suction line, as well as exergy efficiency of the heat pump were analysed as a function of the mean temperature of the cascade heat exchanger.


Vestnik MEI ◽  
2019 ◽  
Vol 6 ◽  
pp. 58-63
Author(s):  
Konstantin V. Strogonov ◽  
◽  
Andrey A. Chaymelov ◽  

2010 ◽  
Vol 44-47 ◽  
pp. 2433-2437 ◽  
Author(s):  
Yu Lieh Wu ◽  
Yu Dai Shiue ◽  
Kuo Hsiang Chien ◽  
Chiu Li Wang

To avoid continuous damage of ozone layer and deterioration of global warming, many countries have devoted to the development and application of natural refrigerant. Although CO2, an alternative refrigerant in the area of air conditioning is not the best all-temperature refrigerant, it has the lowest operating risk as compared to hydrocarbon (HCs) and ammonia.Traditional drinking fountain provides heat source through secondary energy source - electric heating; however, the heating effect is limited. Since heat pump has a high performance, this study used a carbon dioxide heat pump, which has energy-saving effect and high efficiency, to provide heat source to drinking fountains. It further assembled the drinking fountain system with carbon dioxide heat pump and analyzed its performance.


BIOPHYSICS ◽  
2007 ◽  
Vol 52 (6) ◽  
pp. 640-644 ◽  
Author(s):  
A. K. Pavlov ◽  
V. N. Shelegedin ◽  
V. T. Kogan ◽  
A. A. Pavlov ◽  
M. A. Vdovina ◽  
...  