Patient-specific Region-of-Interest Fluoroscopy Device for X-ray Dose Reduction

Radiology ◽  
2003 ◽  
Vol 226 (2) ◽  
pp. 585-592 ◽  
Author(s):  
Tong Xu ◽  
Huy Quang Le ◽  
Sabee Molloi
2020 ◽  
Vol 188 (3) ◽  
pp. 322-331
Author(s):  
Ljubisa Borota ◽  
Andreas Patz

Abstract Aim of the study: The aim of this study was to describe a new functionality aimed at X-ray dose reduction, referred to as spot region of interest (Spot ROI) and to compare it with existing dose-saving functionalities, spot fluoroscopy (Spot F), and conventional collimation (CC). Material and methods: Dose area product, air kerma, and peak skin dose were measured for Spot ROI, Spot F, and CC in three different fields of view (FOVs) 20 × 20 cm, 15 × 15 cm, and 11 × 11 cm using an anthropomorphic head phantom RS-230T. The exposure sequence was 5 min of pulsed fluoroscopy (7.5 pulses per s) followed by 7× digital subtraction angiography (DSA) runs with 30 frames per DSA acquisition (3 fps × 10 s). The collimation in Spot F and CC was adjusted such that the size of the anatomical area exposed was as large as the Spot ROI area in each FOV. Results: The results for all FOVs were the following: for the fluoroscopy, all measured parameters for Spot ROI and Spot F were lower than corresponding values for CC. For DSA and DSA plus fluoroscopy, all measured parameters for Spot ROI were lower than corresponding parameters for Spot F and CC. Conclusion: Spot ROI is a promising dose-saving technology that can be applied in fluoroscopy and acquisition. The biggest benefit of Spot ROI is its ability to keep the entire FOV information always visible.


Author(s):  
Yixing Huang ◽  
Leonid Mill ◽  
Robert Stoll ◽  
Lasse Kling ◽  
Oliver Aust ◽  
...  

2011 ◽  
Author(s):  
Steve Burion ◽  
Anne Sandman ◽  
Kate Bechtel ◽  
Edward Solomon ◽  
Tobias Funk

2015 ◽  
pp. 50-58
Author(s):  
Thi Dung Nguyen ◽  
Tam Vo

Background: The patients on hemodialysis have a significantly decreased quality of life. One of many problems which reduce the quality of life and increase the mortality in these patients is osteoporosis and osteoporosis associated fractures. Objectives: To assess the bone density of those on hemodialysis by dual energy X ray absorptiometry and to examine the risk factors of bone density reduction in these patients. Patients and Method: This is a cross-sectional study, including 93 patients on chronic hemodialysis at the department of Hemodialysis at Cho Ray Hospital. Results: Mean bone densities at the region of interest (ROI) neck, trochanter, Ward triangle, intertrochanter and total neck are 0.603 ± 0.105; 0.583 ± 0.121; 0.811 ± 0.166; 0.489 ± 0.146; 0.723 ± 0.138 g/cm2 respectively. The prevalences of osteoporosis at those ROI are 39.8%, 15.1%; 28%; 38.7%; and 26.9% respectively. The prevalences of osteopenia at those ROI are 54.8%; 46.3%; 60.2%; 45.2% and 62.7% respectively. The prevalence of osteopososis in at least one ROI is 52.7% and the prevalence of osteopenia in at least one ROI is 47.3%. There are relations between the bone density at the neck and the gender of the patient and the albuminemia. Bone density at the trochanter is influenced by gender, albuminemia, calcemia and phosphoremia. Bone density at the intertrochanter is affected by the gender. Bone density at the Ward triangle is influenced by age and albuminemia. Total neck bone density is influenced by gender, albuminemia and phosphoremia. Conclusion: Osteoporosis in patients on chronic hemodialysis is an issue that requires our attention. There are many interventionable risk factors of bone density decrease in these patients. Key words: Osteoporosis, DEXA, chronic renal failure, chronic hemodialysis


2021 ◽  
Author(s):  
Muhammad U. Ghani ◽  
Xizeng Wu ◽  
Laurie L. Fajardo ◽  
Zhengxue Jing ◽  
Molly D. Wong ◽  
...  

2021 ◽  
Vol 11 (3) ◽  
pp. 1038
Author(s):  
Sara Condino ◽  
Giuseppe Turini ◽  
Virginia Mamone ◽  
Paolo Domenico Parchi ◽  
Vincenzo Ferrari

Simulation for surgical training is increasingly being considered a valuable addition to traditional teaching methods. 3D-printed physical simulators can be used for preoperative planning and rehearsal in spine surgery to improve surgical workflows and postoperative patient outcomes. This paper proposes an innovative strategy to build a hybrid simulation platform for training of pedicle screws fixation: the proposed method combines 3D-printed patient-specific spine models with augmented reality functionalities and virtual X-ray visualization, thus avoiding any exposure to harmful radiation during the simulation. Software functionalities are implemented by using a low-cost tracking strategy based on fiducial marker detection. Quantitative tests demonstrate the accuracy of the method to track the vertebral model and surgical tools, and to coherently visualize them in either the augmented reality or virtual fluoroscopic modalities. The obtained results encourage further research and clinical validation towards the use of the simulator as an effective tool for training in pedicle screws insertion in lumbar vertebrae.