Alveolar slope and dead space of He and SF6 in dogs: comparison of airway and venous loading

1990 ◽  
Vol 69 (3) ◽  
pp. 937-944 ◽  
Author(s):  
M. Meyer ◽  
K. D. Schuster ◽  
H. Schulz ◽  
M. Mohr ◽  
J. Piiper

Series (Fowler) dead space (VD) and slope of the alveolar plateau of two inert gases (He and SF6) with similar blood-gas partition coefficients (approximately 0.01) but different diffusivities were analyzed in 10 anesthetized paralyzed mechanically ventilated dogs (mean body wt 20 kg). Single-breath constant-flow expirograms were simultaneously recorded in two conditions: 1) after equilibration of lung gas with the inert gases at tracer concentrations [airway loading (AL)] and 2) during steady-state elimination of the inert gases continuously introduced into venous blood by a membrane oxygenator and partial arteriovenous bypass [venous loading (VL)]. VD was consistently larger for SF6 than for He, but there was no difference between AL and VL. The relative alveolar slope, defined as increment of partial pressure per increment of expired volume and normalized to mixed expired-inspired partial pressure difference, was larger by a factor of two in VL than in AL for both He and SF6. The He-to-SF6 ratio of relative alveolar slope was generally smaller than unity in both VL and AL. Whereas unequal ventilation-volume distribution combined with sequential emptying of parallel lung regions appears to be responsible for the sloping alveolar plateau during AL, the steeper slope during VL is attributed to the combined effects of continuing gas exchange and ventilation-perfusion inequality coupled with sequential emptying. The differences between He and SF6 point at the contributing role of diffusion-dependent mechanisms in intrapulmonary gas mixing.

2008 ◽  
Vol 105 (6) ◽  
pp. 1944-1949 ◽  
Author(s):  
Jérôme Devaquet ◽  
Björn Jonson ◽  
Lisbet Niklason ◽  
Anne-Gaëlle Si Larbi ◽  
Leif Uttman ◽  
...  

A high respiratory rate associated with the use of small tidal volumes, recommended for acute lung injury (ALI), shortens time for gas diffusion in the alveoli. This may decrease CO2 elimination. We hypothesized that a postinspiratory pause could enhance CO2 elimination and reduce PaCO2 by reducing dead space in ALI. In 15 mechanically ventilated patients with ALI and hypercapnia, a 20% postinspiratory pause (Tp20) was applied during a period of 30 min between two ventilation periods without postinspiratory pause (Tp0). Other parameters were kept unchanged. The single breath test for CO2 was recorded every 5 min to measure tidal CO2 elimination (VtCO2), airway dead space (VDaw), and slope of the alveolar plateau. PaO2, PaCO2, and physiological and alveolar dead space (VDphys, VDalv) were determined at the end of each 30-min period. The postinspiratory pause, 0.7 ± 0.2 s, induced on average <0.5 cmH2O of intrinsic positive end-expiratory pressure (PEEP). During Tp20, VtCO2 increased immediately by 28 ± 10% (14 ± 5 ml per breath compared with 11 ± 4 for Tp0) and then decreased without reaching the initial value within 30 min. The addition of a postinspiratory pause significantly decreased VDaw by 14% and VDphys by 11% with no change in VDalv. During Tp20, the slope of the alveolar plateau initially fell to 65 ± 10% of baseline value and continued to decrease. Tp20 induced a 10 ± 3% decrease in PaCO2 at 30 min (from 55 ± 10 to 49 ± 9 mmHg, P < 0.001) with no significant variation in PaO2. Postinspiratory pause has a significant influence on CO2 elimination when small tidal volumes are used during mechanical ventilation for ALI.


1992 ◽  
Vol 72 (4) ◽  
pp. 1557-1562 ◽  
Author(s):  
H. Schulz ◽  
P. Heilmann ◽  
A. Hillebrecht ◽  
J. Gebhart ◽  
M. Meyer ◽  
...  

The significance of convective and diffusive gas transport in the respiratory system was assessed from the response of combined inert gas and particle boluses inhaled into the conducting airways. Particles, considered as “nondiffusing gas,” served as tracers for convection and two inert gases with widely different diffusive characteristics (He and SF6) as tracers for convection and diffusion. Six-milliliter boluses labeled with monodisperse di-2-ethylhexyl sebacate droplets of 0.86-microns aerodynamic diameter, 2% He, and 2% SF6 were inspired by three anesthetized mechanically ventilated beagle dogs to volumetric lung depths up to 170 ml. Mixing between inspired and residual air caused dispersion of the inspired bolus, which was quantified in terms of the bolus half-width. Dispersion of particles increased with increasing lung depth to which the boluses were inhaled. The increase followed a power law with exponents less than 0.5 (mean 0.39), indicating that the effect of convective mixing per unit volume was reduced with depth. Within the pulmonary dead space, the behavior of the inert gases He and SF6 was similar to that of the particles, suggesting that gas transport was almost solely due to convection. Beyond the dead space, dispersion of He and SF6 increased more rapidly than dispersion of particles, indicating that diffusion became significant. The gas and particle bolus technique offers a suitable approach to differential analysis of gas transport in intrapulmonary airways of lungs.


1983 ◽  
Vol 55 (6) ◽  
pp. 1795-1802 ◽  
Author(s):  
M. Meyer ◽  
C. Hook ◽  
H. Rieke ◽  
J. Piiper

Simultaneously measured helium (He) and sulfur hexafluoride (SF6) single-breath washout was studied in 16 anesthetized paralyzed dogs ventilated with a special hydraulically operated ventilatory servo system. After equilibration of lung gas with 1% He and 1% SF6, the maneuver consisting of inspiration of a test gas-free mixture at constant rate (VI), a variable time of breath holding, and an expiration at constant rate (VE), was performed. Fractional concentrations of He and SF6, recorded against expired volume, were analyzed in terms of slope of the alveolar plateau (S) and series (Fowler) dead space (VD). In control conditions (VI = 0.5 l/s, VE = 0.1 l/s) S was about 10% of alveolar-to-inspired concentration difference per liter expirate both for He and SF6. Both SHe and SSF6 were inversely related to VI and VE, the relative changes being more pronounced with varying VE. SHe/SSF6 was higher or lower than unity depending on VI and VE. Both SHe and SSF6 decreased with increasing preinspiratory lung volume. Breath holding up to 10 s slightly decreased SHe and SSF6 while SHe/SSF6 was unchanged. The contribution of continuing gas exchange to S assessed from comparative measurements using the reversed (single breath washin) technique ranged from 6 to 23% in the various conditions. The VDHe/VDSF6 ratio was 0.84 and was little affected in the various settings. Results indicate that the substantial alveolar gas inhomogeneity in the dog lung and the mechanism accounting for S are little diffusion dependent. By exclusion sequential filling and emptying of lung units is believed to constitute the most important mechanism responsible for the sloping alveolar plateau.


1997 ◽  
Vol 83 (1) ◽  
pp. 240-246 ◽  
Author(s):  
Steven Deem ◽  
Michael K. Alberts ◽  
Michael J. Bishop ◽  
Akhil Bidani ◽  
Erik R. Swenson

Deem, Steven A., Michael K. Alberts, Michael J. Bishop, Akhil Bidani, and Erik R. Swenson.CO2transport in normovolemic anemia: complete compensation and stability of blood CO2tensions. J. Appl. Physiol. 83(1): 240–246, 1997.—Isovolemic hemodilution does not appear to impair CO2elimination nor cause CO2retention despite the important role of red blood cells in blood CO2transport. We studied this phenomenon and its physiological basis in eight New Zealand White rabbits that were anesthetized, paralyzed, and mechanically ventilated at a fixed minute ventilation. Isovolemic anemia was induced by simultaneous blood withdrawal and infusion of 6% hetastarch in sequential stages; exchange transfusions ranged from 15–30 ml in volume. Variables measured after each hemodilution included hematocrit (Hct), arterial and venous blood gases, mixed expired[Formula: see text] and[Formula: see text], and blood pressure; also, O2consumption, CO2production, cardiac output (Q˙), and physiological dead space were calculated. Data were analyzed by comparison of changes in variables with changes in Hct and by using the model of capillary gas exchange described by Bidani ( J. Appl. Physiol. 70: 1686–1699, 1991). There was complete compensation for anemia with stability of venous and arterial [Formula: see text]between Hct values of 36 ± 3 and 12 ± 1%, which was predicted by the mathematical model. Over this range of hemodilution,Q˙ rose 50%, and the O2extraction ratio increased 61% without a decline in CO2production or a rise in alveolar ventilation. The dominant compensations maintaining CO2transport in normovolemic anemia include an increasedQ˙ and an augmented Haldane effect arising from the accompanying greater O2extraction.


1990 ◽  
Vol 69 (3) ◽  
pp. 945-955 ◽  
Author(s):  
M. Meyer ◽  
S. M. Lewis ◽  
M. Mohr ◽  
H. Schulz ◽  
K. D. Schuster ◽  
...  

Cardiogenic oscillations in the expired partial pressure profiles of two inert gases (He and SF6) were monitored in seven anesthetized paralyzed mechanically ventilated dogs. He and SF6 were administered either intravenously by a membrane oxygenator and partial arteriovenous bypass [venous loading (VL)] or by washin into lung gas [airway loading (AL)]. The single-breath expirograms obtained during constant-flow expiration after inspiration of test gas-free air displayed distinct and regular cardiogenic oscillations. The relative oscillation amplitude (ROA), calculated as oscillation amplitude divided by mixed expired-inspired partial pressure difference, was in the range of 1-8%. The ROA for both He and SF6 was approximately 4.2 times higher in VL than in AL, which indicated that among lung units that emptied sequentially in the cardiac cycle, the effects of alveolar ventilation-perfusion (VA/Q) inequality were more pronounced than those of alveolar ventilation-alveolar volume (VA/VA) inequality. In AL, He and SF6 oscillations were 180 degrees out of phase compared with CO2 and O2 oscillations and with He and SF6 oscillations in VL, which suggests that regions with low VA/VA had high VA/Q and very low Q/VA. The ROA was practically unaffected by breath holding in both AL and VL, which indicates that there was little diffusive or convective (cardiogenic) mixing between the lung units that were responsible for cardiogenic oscillations. The ROA was consistently higher for He than for SF6, and the He-to-SF6 ratio was independent of route of test gas loading, averaging 1.6 in both AL and VL. This result may be explained by laminar Taylor dispersion, whereby oscillations generated in peripheral lung regions are dissipated in inverse proportion to diffusion coefficient during transit through the proximal (larger) airways.


2019 ◽  
pp. 203-206
Author(s):  
Mevlut Demir ◽  
◽  
Muslum Sahin ◽  
Ahmet Korkmaz ◽  
◽  
...  

Carbon monoxide intoxication occurs usually via inhalation of carbon monoxide that is emitted as a result of a fire, furnace, space heater, generator, motor vehicle. A 37-year-old male patient was admitted to the emergency department at about 5:00 a.m., with complaints of nausea, vomiting and headache. He was accompanied by his wife and children. His venous blood gas measures were: pH was 7.29, partial pressure of carbon dioxide (pCO2) was 42 mmHg, partial pressure of oxygen (pO2) was 28 mmHg, carboxyhemoglobin (COHb) was 12.7% (reference interval: 0.5%-2.5%) and oxygen saturation was 52.4%. Electrocardiogram (ECG) examination showed that the patient was not in sinus rhythm but had atrial fibrillation. After three hours the laboratory examination was repeated: Troponin was 1.2 pg/ml and in the arterial blood gas COHb was 3%. The examination of the findings on the monitor showed that the sinus rhythm was re-established. The repeated ECG examination confirmed the conversion to the sinus rhythm. He was monitored with the normobaric oxygen administration.


2021 ◽  
Vol 11 (3) ◽  
pp. 164
Author(s):  
Mahmoud Al-Obeidallah ◽  
Dagmar Jarkovská ◽  
Lenka Valešová ◽  
Jan Horák ◽  
Jan Jedlička ◽  
...  

Porcine model of peritonitis-induced sepsis is a well-established clinically relevant model of human disease. Interindividual variability of the response often complicates the interpretation of findings. To better understand the biological basis of the disease variability, the progression of the disease was compared between animals with sepsis and septic shock. Peritonitis was induced by inoculation of autologous feces in fifteen anesthetized, mechanically ventilated and surgically instrumented pigs and continued for 24 h. Cardiovascular and biochemical parameters were collected at baseline (just before peritonitis induction), 12 h, 18 h and 24 h (end of the experiment) after induction of peritonitis. Analysis of multiple parameters revealed the earliest significant differences between sepsis and septic shock groups in the sequential organ failure assessment (SOFA) score, systemic vascular resistance, partial pressure of oxygen in mixed venous blood and body temperature. Other significant functional differences developed later in the course of the disease. The data indicate that SOFA score, hemodynamical parameters and body temperature discriminate early between sepsis and septic shock in a clinically relevant porcine model. Early pronounced alterations of these parameters may herald a progression of the disease toward irreversible septic shock.


Author(s):  
Kirsty L. Ress ◽  
Gus Koerbin ◽  
Ling Li ◽  
Douglas Chesher ◽  
Phillip Bwititi ◽  
...  

AbstractObjectivesVenous blood gas (VBG) analysis is becoming a popular alternative to arterial blood gas (ABG) analysis due to reduced risk of complications at phlebotomy and ease of draw. In lack of published data, this study aimed to establish reference intervals (RI) for correct interpretation of VBG results.MethodsOne hundred and 51 adult volunteers (101 females, 50 males 18–70 y), were enrolled after completion of a health questionnaire. Venous blood was drawn into safePICO syringes and analysed on ABL827 blood gas analyser (Radiometer Pacific Pty. Ltd.). A non-parametric approach was used to directly establish the VBG RI which was compared to a calculated VBG RI based on a meta-analysis of differences between ABG and VBGResultsAfter exclusions, 134 results were used to derive VBG RI: pH 7.30–7.43, partial pressure of carbon dioxide (pCO2) 38–58 mmHg, partial pressure of oxygen (pO2) 19–65 mmHg, bicarbonate (HCO3−) 22–30 mmol/L, sodium 135–143 mmol/L, potassium 3.6–4.5 mmol/L, chloride 101–110 mmol/L, ionised calcium 1.14–1.29 mmol/L, lactate 0.4–2.2 mmol/L, base excess (BE) −1.9–4.5 mmol/L, saturated oxygen (sO2) 23–93%, carboxyhaemoglobin 0.4–1.4% and methaemoglobin 0.3–0.9%. The meta-analysis revealed differences between ABG and VBG for pH, HCO3−, pCO2 and pO2 of 0.032, −1.0 mmol/L, −4.2 and 39.9 mmHg, respectively. Using this data along with established ABG RI, calculated VBG RI of pH 7.32–7.42, HCO3− 23 – 27 mmol/L, pCO2 36–49 mmHg (Female), pCO2 39–52 mmHg (Male) and pO2 43–68 mmHg were formulated and compared to the VBG RI of this study.ConclusionsAn adult reference interval has been established to assist interpretation of VBG results.


1994 ◽  
Vol 76 (5) ◽  
pp. 2130-2139 ◽  
Author(s):  
E. M. Williams ◽  
J. B. Aspel ◽  
S. M. Burrough ◽  
W. A. Ryder ◽  
M. C. Sainsbury ◽  
...  

A theoretical model (Hahn et al. J. Appl. Physiol. 75: 1863–1876, 1993) predicts that the amplitudes of the argon and nitrous oxide inspired, end-expired, and mixed expired sinusoids at forcing periods in the range of 2–3 min (frequency 0.3–0.5 min-1) can be used directly to measure airway dead space, lung alveolar volume, and pulmonary blood flow. We tested the ability of this procedure to measure these parameters continuously by feeding monosinusoidal argon and nitrous oxide forcing signals (6 +/- 4% vol/vol) into the inspired airstream of nine anesthetized ventilated dogs. Close agreement was found between single-breath and sinusoid airway dead space measurements (mean difference 15 +/- 6%, 95% confidence limit), N2 washout and sinusoid alveolar volume (mean difference 4 +/- 6%, 95% confidence limit), and thermal dilution and sinusoid pulmonary blood flow (mean difference 12 +/- 11%, 95% confidence limit). The application of 1 kPa positive end-expiratory pressure increased airway dead space by 12% and alveolar volume from 0.8 to 1.1 liters but did not alter pulmonary blood flow, as measured by both the sinusoid and comparator techniques. Our findings show that the noninvasive sinusoid technique can be used to measure cardiorespiratory lung function and allows changes in function to be resolved in 2 min.


2021 ◽  
pp. 1-16
Author(s):  
Marcin Adamczak ◽  
Stanisław Surma

<b><i>Background:</i></b> Metabolic acidosis in CKD is diagnosed in patients with plasma or venous blood bicarbonate concentration lower than 22 mmol/L. Metabolic acidosis occurs in about 20% of patients with CKD. Metabolic acidosis may lead to dysfunction of many systems and organs as well as CKD progression. Currently, sodium bicarbonate is mainly used for pharmacological treatment of metabolic acidosis in patients with CKD. Veverimer is a new drug dedicated to treatment of metabolic acidosis in patients with CKD. Orally given veverimer binds hydrogen ions in the intestines and subsequently is excreted from the body with feces. Clinical studies have shown that veverimer is effective in increasing serum bicarbonate concentrations in CKD patients with metabolic acidosis. Here, we present review of the epidemiology, pathogenesis, diagnosis, treatment, and prevention of metabolic acidosis in CKD patients. <b><i>Summary:</i></b> Metabolic acidosis is common in patients with CKD and contributes to CKD progression and many complications, which worsen the prognosis in these patients. Currently, sodium bicarbonate is mainly used in metabolic acidosis treatment. The role of the new drug veverimer in the metabolic acidosis therapy needs further studies. <b><i>Key Message:</i></b> The aim of this review article is to summarize the current knowledge concerning the epidemiology, pathogenesis, diagnosis, treatment, and prevention of metabolic acidosis in CKD patients.


Sign in / Sign up

Export Citation Format

Share Document