single breath
Recently Published Documents


TOTAL DOCUMENTS

958
(FIVE YEARS 108)

H-INDEX

57
(FIVE YEARS 4)

2021 ◽  
Vol 11 (1) ◽  
pp. 179
Author(s):  
Yaroslava Longhitano ◽  
Christian Zanza ◽  
Tatsiana Romenskaya ◽  
Angela Saviano ◽  
Tonia Persiano ◽  
...  

The use of non-invasive respiratory strategies (NIRS) is crucial to improve oxygenation in COVID-19 patients with hypoxemia refractory to conventional oxygen therapy. However, the absence of respiratory symptoms may delay the start of NIRS. The aim of this study was to determine whether a simple bedside test such as single-breath counting test (SBCT) can predict the need for NIRS in the 24 h following the access to Emergency Department (ED). We performed a prospective observational study on 120 patients with COVID-19 pneumonia. ROC curves were used to analyze factors which might predict NIRS requirement. We found that 36% of patients had normal respiratory rate and did not experience dyspnea at rest. 65% of study population required NIRS in the 24 h following the access to ED. NIRS-requiring group presented lower PaO2/FiO2 (235.09 vs. 299.02), SpO2/FiO2 ratio (357.83 vs. 431.07), PaCO2 (35.12 vs. 40.08), and SBCT (24.46 vs. 30.36) and showed higher incidence of dyspnea at rest (57.7% vs. 28.6%). Furthermore, SBCT predicted NIRS requirement even in the subgroup of patients without respiratory symptoms (AUC = 0.882, cut-off = 30). SBCT might be a valuable tool for bedside assessment of respiratory function in patients with COVID-19 pneumonia and might be considered as an early clinical sign of impending respiratory deterioration.


Author(s):  
Diana Bencikova ◽  
Fei Han ◽  
Stephan Kannengieser ◽  
Marcus Raudner ◽  
Sarah Poetter-Lang ◽  
...  

Abstract Objectives T2 mapping of the liver is a potential diagnostic tool, but conventional techniques are difficult to perform in clinical practice due to long scan time. We aimed to evaluate the accuracy of a prototype radial turbo-spin-echo (rTSE) sequence, optimized for multi-slice T2 mapping in the abdomen during one breath-hold at 3 T. Methods A multi-sample (fat: 0–35%) agarose phantom doped with MnCl2 and 80 subjects (73 patients undergoing abdomen MR examination and 7 healthy volunteers) were investigated. A radial turbo-spin-echo (rTSE) sequence with and without fat suppression, a Cartesian turbo-spin-echo (Cart-TSE) sequence, and a single-voxel multi-echo STEAM spectroscopy (HISTO) were performed in phantom, and fat-suppressed rTSE and HISTO sequences were performed in in vivo measurements. Two approaches were used to sample T2 values: manually selected circular ROIs and whole liver analysis with Gaussian mixture models (GMM). Results The rTSE-T2s values exhibited a strong correlation with Cart-TSE-T2s (R2 = 0.988) and with HISTO-T2s of water (R2 = 0.972) in phantom with an offset between rTSE and Cart-TSE maps (mean difference = 3.17 ± 1.18 ms). The application of fat suppression decreased T2 values, and the effect was directly proportional to the amount of fat. Measurements in patients yielded a linear relationship between rTSE- and HISTO-T2s (R2 = 0.546 and R2 = 0.580 for ROI and GMM, respectively). Conclusion The fat-suppressed rTSE sequence allows for fast and accurate determination of T2 values of the liver, and appears to be suitable for further large cohort studies. Key Points •Radial turbo-spin-echo T2 mapping performs comparably to Cartesian TSE-T2 mapping, but an offset in values is observed in phantom measurements. •Fat-suppressed radial turbo-spin-echo T2 mapping is consistent with T2 of water as assessed by MRS in phantom measurements. •Fat-suppressed radial turbo-spin-echo sequence allows fast T2 mapping of the liver in a single breath-hold and is correlated with MRS-based T2 of water.


2021 ◽  
Author(s):  
Alexander Ruesch ◽  
J. Chris McKnight ◽  
Eric Mulder ◽  
Jingyi Wu ◽  
Steve Balfour ◽  
...  

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Susann-Cathrin Olthof ◽  
Christian Reinert ◽  
Konstantin Nikolaou ◽  
Christina Pfannenberg ◽  
Sergios Gatidis ◽  
...  

Abstract Background Detection of pulmonary nodules in MRI requires fast imaging strategies without respiratory motion impairment, such as single-breath-hold Cartesian VIBE. As patients with pulmonary diseases have limited breath-hold capacities, this study investigates the clinical feasibility of non-Cartesian Spiral VIBE under free-breathing compared to CT as the gold standard. Methods Prospective analysis of 27 oncological patients examined in PET/CT and PET/MR. A novel motion-robust 3D ultrashort-echo-time (UTE) MR sequence was evaluated in comparison with CT and conventional breath-hold MR. CT scans were performed under breath-hold in end-expiratory and end-inspiratory position (CT ex, CT in). MR data was acquired with non-contrast-enhanced breath-hold Cartesian VIBE followed by a free-breathing 3D UTE Spiral VIBE. Impact of respiratory motion on pulmonary evaluation was investigated by two readers in Cartesian VIBE, followed by UTE Spiral VIBE and CT ex and the reference standard of CT in. Diagnostic accuracy was calculated, and visual image quality assessed. Results Higher detection rate and sensitivity of pulmonary nodules in free-breathing UTE Spiral VIBE in comparison with breath-hold Cartesian VIBE were found for lesions > 10 mm (UTE Spiral VIBE/VIBE/CT ex): 93%/54%/100%; Lesions 5–10 mm: 67%/25%/ 92%; Lesions < 5 mm: 11%/11%/78%. Lobe-based analysis revealed sensitivities and specificities of 64%/96%/41% and 96%/93%/100% for UTE Spiral VIBE/VIBE/CT ex. Conclusion Free-breathing UTE Spiral VIBE indicates higher sensitivity for detection of pulmonary nodules than breath-hold Cartesian VIBE and is a promising but time-consuming approach. However, sensitivity and specificity of inspiratory CT remain superior in comparison and should be preferred for detection of pulmonary lesions.


Author(s):  
Corona Metz ◽  
David Böckle ◽  
Julius Frederik Heidenreich ◽  
Andreas Max Weng ◽  
Thomas Benkert ◽  
...  

Purpose To evaluate the feasibility of non-contrast-enhanced three-dimensional ultrashort echo time (3D-UTE) MRI for pulmonary imaging in immunocompromised patients during hematopoietic stem cell transplantation (HSCT). Methods MRI was performed using a stack-of-spirals 3D-UTE sequence (slice thickness: 2.34mm; matrix: 256 × 256; acquisition time: 12.7–17.6 seconds) enabling imaging of the entire thorax within single breath-holds. Patients underwent MRI before HSCT initiation, in the case of periprocedural pneumonia, before discharge, and in the case of re-hospitalization. Two readers separately assessed the images regarding presence of pleural effusions, ground glass opacities (GGO), and consolidations on a per lung basis. A T2-weighted (T2w) multi-shot Turbo Spin Echo sequence (BLADE) was acquired in coronal orientation during breath-hold (slice thickness: 6.00mm; matrix: 320 × 320; acquisition time: 3.1–5.5 min) and read on a per lesion basis. Low-dose CT scans in inspiration were used as reference and were read on a per lung basis. Only scans performed within a maximum of three days were included in the inter-method analyses. Interrater agreement, sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of 3D-UTE MRI were calculated. Results 67 MRI scans of 28 patients were acquired. A reference CT examination was available for 33 scans of 23 patients. 3D-UTE MRI showed high sensitivity and specificity regarding pleural effusions (n = 6; sensitivity, 92 %; specificity, 100 %) and consolidations (n = 22; sensitivity 98 %, specificity, 86 %). Diagnostic performance was lower for GGO (n = 9; sensitivity, 63 %; specificity, 84 %). Accuracy rates were high (pleural effusions, 98 %; GGO, 79 %; consolidations 94 %). Interrater agreement was substantial for consolidations and pleural effusions (κ = 0.69–0.82) and moderate for GGO (κ = 0.54). Compared to T2w imaging, 3D-UTE MRI depicted the assessed pathologies with at least equivalent quality and was rated superior regarding consolidations and GGO in ~50 %. Conclusion Non-contrast 3D-UTE MRI enables radiation-free assessment of typical pulmonary complications during HSCT procedure within a single breath-hold. Yet, CT was found to be superior regarding the identification of pure GGO changes. Key Points:  Citation Format


Author(s):  
Sushama A. Bhandare ◽  
Sayali S. Rasal ◽  
Anil M. Sathe ◽  
Vaishnavi R. Nagpure ◽  
Urvi B. Parmar ◽  
...  

Background: The novel Coronavirus is known to primarily affect the respiratory system and physiotherapy treatment is integral to combat this infection. However, the assessment of pulmonary function poses a difficult challenge considering the risk of spread of infection and sanitisation of the devices used. Single breath count (SBC) and breath holding time (BHT) can be thus adopted as bedside assessment tests for pulmonary function following physiotherapy treatment.Method: In this a retrospective observational study of 51 COVID-19 patients, mean age 51.7±14.56 years, on room air, admitted in the step-down units of a tertiary care hospital. Patients received standard physiotherapy treatment, within safe hemodynamic limits. Pre and post treatment session SBC was recorded in 32 patients and BHT in 19 patients. Three reading were noted and the best of three readings were used for analysis.Results: The paired t test was used to analyse SBC and BHT. Mean pre and post SBC was 18.25±8.96 and 23.31±9.96 respectively with a mean difference of 5.06 and p<0.0001. Mean pre and post BHT were 19.37 and 23.05 seconds respectively with a mean difference of 3.68 and p<0.0001.  Statistically significant difference in the pre and post treatment session SBC and BHT was observed, indicating a positive effect of physiotherapy treatment on pulmonary function.Conclusion: Physiotherapy treatment shows significant improvement in the pulmonary function in COVID-19 patients. SBC and BHT tests can be used as assessment and prognostic tools for pulmonary function in COVID-19 patients.


2021 ◽  
Vol 8 ◽  
Author(s):  
Qing Liu ◽  
Lingxiao Zhou ◽  
Peiling Feng ◽  
Jinkai Liu ◽  
Bin Shen ◽  
...  

Background: Whole-body plethysmography (WBP) is the gold standard for measuring lung volume, but its clinical application is limited as it requires expensive equipment and is not simple to use. Studies have shown that the single-breath helium dilution (SBHD) method, which is commonly used in clinical practice, significantly underestimates lung volume in patients with obstructive lung disease (OLD). By comparing the differences in lung volume measured using SBHD and WBP, we aimed to establish a correction equation for the SBHD method to determine the total lung volume in patients with OLD of different severities.Methods: From 628 patients with OLD simultaneously subjected to SBHD and WBP, 407 patients enrolled between January 2018 and November 2019 were in the training group and 221 enrolled between December 2019 and December 2020 were in the prospective verification cohort. The multiple linear regression equation was used for data in the training group to establish a correction equation for SBHD to determine the total lung volume, and this was validated in the prospective validation cohort.Results: There was a moderate positive correlation between total lung capacity (TLC) determined using the SBHD [TLC (SBHD)] and WBP methods [TLC (WBP)] (r = 0.701; P &lt; 0.05), and the differences between TLC (SBHD) and TLC (WBP) (ΔTLC) were related to the severity of obstruction. As the severity of obstruction increased, the TLC was underestimated by the SBHD method. We established the following correction equation: TLC (adjusted SBHD) (L) = −0.669 + 0.756*TLC(SBHD)(L) – 0.047*FEV1FVC+0.039*height (cm)–0.009*weight(kg)(r2 = 0.753 and adjusted r2 = 0.751). Next, we validated this equation in the validation cohort. With the correction equation, no statistical difference was observed between TLC (adjusted SBHD) and TLC (WBP) among the obstruction degree groups (P &gt; 0.05).Conclusions: The SBHD method is correlated with WBP to measure the total lung volume, but the SBHD method presents limitations in determining the total lung volume in patients with obstructive lung disease. Here, we established an effective and reliable correction equation in order to accurately assess the total lung volume of patients with OLD using the SBHD method.


Author(s):  
Francesco Pistelli ◽  
Duane L. Sherrill ◽  
Sandra Baldacci ◽  
Sara Maio ◽  
Laura Carrozzi ◽  
...  

2021 ◽  
Vol 161 ◽  
pp. S93-S95
Author(s):  
S. Parveen ◽  
M. Parkes ◽  
E. Wingate ◽  
B. Shingler ◽  
S. Green ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document