Simple validation for the hepatic venous cannula implanted chronically in conscious rats

1991 ◽  
Vol 71 (1) ◽  
pp. 359-364 ◽  
Author(s):  
M. T. Huang

A method for the detection of vena caval contamination in blood taken from hepatic venous cannulas in conscious rats was described. The procedures included 1) bolus injection of tritiated water (50 microCi) through a cannula into the abdominal inferior vena cava and 2) continuous blood sampling (less than 0.2 ml) from the hepatic venous cannula for 2 min into a 180-cm piece of Tygon tubing, starting concurrently with tracer injection. The washout of tritium was determined from samples in 15-cm sections of Tygon tubing. Because circulation from the inferior vena cava to the hepatic vein is interceded by the systemic circulation, the washout of tritium from a valid hepatic venous cannula should resemble the pattern determined elsewhere in the systemic circulation. In the current study, the reference systemic washout was determined in the superior vena cava of a group of rats similarly injected with tritiated water in the inferior vena cava. The maximum of tritium washout derived from a valid hepatic venous cannula should fall in the range encompassed by one standard deviation of the mean of the maximum of the reference (1,400 to 1,930 cpm/sample). The maximum of the washout pattern derived from the invalid cannula, which lay adjacent to the site of injection, was expected to exceed this range. On the basis of these criteria, hepatic blood flow (HBF) was determined by sulfbromophthalein (BSP) extraction in groups of rats with valid and invalid cannulas. HBF in rats with valid hepatic venous cannulas was 2.58 +/- 0.15 in the conscious state and 2.76 +/- 0.26 ml.min-1.g wet wt-1 in the ketamine-anesthetized state.(ABSTRACT TRUNCATED AT 250 WORDS)

2021 ◽  
Vol 5 (2) ◽  
Author(s):  
Masatoshi Narikawa ◽  
Masayoshi Kiyokuni ◽  
Junya Hosoda ◽  
Toshiyuki Ishikawa

Abstract Background Transseptal puncture and pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) are generally performed via the inferior vena cava (IVC). However, in cases where the IVC is inaccessible, a specific strategy may be needed. Case summary An 86-year-old woman with paroxysmal AF and an IVC filter in situ was referred to our hospital for ablation therapy. An IVC filter for pulmonary embolism and deep venous thrombosis had been implanted 15 years prior, therefore we selected a transoesophageal echocardiography (TOE)-guided transseptal puncture using a superior vena cava (SVC) approach. After the single transseptal puncture, we performed fast anatomical mapping, voltage mapping by multipolar mapping catheter, and then PVI by contact force-guided radiofrequency catheter using a steerable sheath. Following the ablation, bidirectional conduction block between the four pulmonary veins and the left atrium was confirmed by both radiofrequency and mapping catheter. No complications occurred and no recurrence of AF was documented in the 12 months after the procedure. Discussion When performing a transseptal puncture during AF ablation, an SVC approach, via access through the right internal jugular vein, enables the sheath to directly approach the left atrium without angulation and improves operability of the ablation catheter. Combining the use of general anaesthesia, TOE, a steerable sheath, and contact force-guided ablation may contribute to achieving minimally invasive PVI with a single transseptal puncture via an SVC approach.


1996 ◽  
Vol 62 (2) ◽  
pp. 566-568 ◽  
Author(s):  
H. Cem Alhan ◽  
lyas Kayacioğlu ◽  
Gülşah Tayyareci ◽  
Cantürk Çakalağaoğlu ◽  
Mustafa diz ◽  
...  

2020 ◽  
Vol 65 (4) ◽  
pp. 403-416
Author(s):  
G. M. Galstyan ◽  
M. V. Spirin ◽  
M. Yu. Drokov ◽  
I. E. Kostina ◽  
Ya. K. Mangasarova

Background. In the superior vena cava syndrome, vein catheterisation provides an alternative for vascular access. Few reports describe the usage of femoral ports.Aim. Description of pros and contras for femoral port installation in patients with haematological malignancies and the superior vena cava syndrome.Materials and methods. This prospective non-randomised, single-centre study included 163 haematological patients implanted 72 ports in superior vena cava, 35 — in inferior vena cava and inserted with 156 non-tunnelled femoral catheters. Catheterisation properties, complications, duration of use and reasons for port and catheter removal were registered.Results. No significant differences were observed between ports in superior and inferior vena cava as per the frequency of urokinase use in catheter dysfunction, catheter dislocation, catheter-associated bloodstream and pocket infections. Differences were revealed in the catheter-associated thrombosis rate, which was higher with femoral access (17.0 % or 0.9/1000 catheter days vs. 8.3 % or 0.2/1000 catheter days, p = 0.017). Ports in inferior vena cava had a lesser duration of use than in superior vena cava (p = 0.0001). Unlike femoral ports, non-tunnelled femoral catheters had higher rates of catheter-associated thrombosis (9/1000 vs. 0.9/1000 catheter days, p = 0.002) and infection (4.9/1000 vs. 0.3/1000 catheter days, p = 0.002). One lymphoma therapy course required one femoral port or 1 to 14 (median 3) non-tunnelled femoral catheters.Conclusion. Femoral port implantation is a necessary measure in patients with the superior vena cava syndrome. It has advantages in terms of catheterisation frequency, lower infectious and thrombotic complication rates compared to non-tunnelled femoral catheters.


1980 ◽  
Vol 238 (4) ◽  
pp. H423-H429 ◽  
Author(s):  
O. Stokland ◽  
M. M. Miller ◽  
A. Ilebekk ◽  
F. Kiil

To examine left ventricular responses to aortic occlusion, changes in end-diastolic volume (EDV) and end-systolic volume (ESV) were estimated by ultrasonic recordings of myocardial distances in atropinized open-chest dogs. During aortic occlusion EDV and ESV increased equally, systolic left ventricular pressure (LVP) rose by 86 +/- 8 mmHg, and blood flow more than doubled in the superior vena cava and fell by 90% in the inferior vena cava. During combined occlusion of aorta and inferior vena cava, systolic LVP and superior vena cava flow did not rise above control and EDV declined. By infusing 25 +/- 2 ml/kg body wt of blood during combined occlusion, the effects of aortic occlusion could be reproduced; control values before blood infusion were reestablished by withdrawal of only one-third of the infused volume, indicating a shunt line along the spinal column. Thus during aortic occlusion, transfer of blood accounts for the rise in EDV and increased activation of the Frank-Starling mechanism; increased afterload raises ESV as much as EDV in anesthetized dogs not subjected to sympathetic stimulation. Consequently, stroke volume is maintained and systolic LVP increased.


Author(s):  
Sara Thorne ◽  
Sarah Bowater

This chapster discusses anomalies of systemic venous drainage and anomalies of pulmonary venous drainage. It discusses superior vena cava (SVC) anomalies, inferior vena cava (IVC), total anomalous pulmonary venous drainage (TAPVD), partial anomalous pulmonary venous drainage (PAPVD), and scimitar syndrome.


Perfusion ◽  
2019 ◽  
Vol 35 (4) ◽  
pp. 306-315
Author(s):  
Muhammad Jamil ◽  
Mohammad Rezaeimoghaddam ◽  
Bilgesu Cakmak ◽  
Yahya Yildiz ◽  
Reza Rasooli ◽  
...  

Objective: Malposition of dual lumen cannula is a frequent and challenging complication in neonates and plays a significant role in shaping the in vitro device hemodynamics. This study aims to analyze the effect of the dual lumen cannula malposition on right-atrial hemodynamics in neonatal patients using an experimentally validated computational fluid dynamics model. Methods: A computer model was developed for clinically approved dual lumen cannula (13Fr Origen Biomedical, Austin, Texas, USA) oriented inside the atrium of a 3-kg neonate with normal venous return. Atrial hemodynamics and dual lumen cannula malposition were systematically simulated for two rotations (antero-atrial and atrio-septal) and four translations (two intravascular movements along inferior vena cava and two dislodged configurations in the atrium). A multi-domain compartmentalized mesh was prepared to allow the site-specific evaluation of important hemodynamic parameters. Transport of each blood stream, blood damage levels, and recirculation times are quantified and compared to dual lumen cannula in proper position. Results: High recirculation levels (39 ± 4%) in malpositioned cases resulted in poor oxygen saturation where maximum recirculation of up to 42% was observed. Apparently, Origen dual lumen cannula showed poor inferior vena cava blood–capturing efficiency (48 ± 8%) but high superior vena cava blood–capturing efficiency (86 ± 10%). Dual lumen cannula malposition resulted in corresponding changes in residence time (1.7 ± 0.5 seconds through the tricuspid). No significant differences in blood damage were observed among the simulated cases compared to normal orientation. Compared to the correct dual lumen cannula position, both rotational and translational displacements of the dual lumen cannula resulted in significant hemodynamic differences. Conclusion: Rotational or translational movement of dual lumen cannula is the determining factor for atrial hemodynamics, venous capturing efficiency, blood residence time, and oxygenated blood delivery. Results obtained through computational fluid dynamics methodology can provide valuable foresight in assessing the performance of the dual lumen cannula in patient-specific configurations.


2016 ◽  
Vol 10 ◽  
pp. CMC.S38153
Author(s):  
Mariana S. Parahuleva ◽  
Mehmet Burgazli ◽  
Nedim Soydan ◽  
Wolfgang Franzen ◽  
Norbert Guttler ◽  
...  

We report an interesting case of a man with a persistent left superior vena cava (PLSVC) with left azygos vein who underwent electrophysiological evaluation. Further evaluation revealed congenital dilated azygos vein, while a segment connecting the inferior vena cava (IVC) to the hepatic vein and right atrium was missing. The azygos vein drained into the superior vena cava, and the hepatic veins drained directly into the right atrium. The patient did not have congenital anomalies of the remaining thoracoabdominal vasculature.


Sign in / Sign up

Export Citation Format

Share Document