On-line measurement of nitric oxide generation in buffer-perfused rabbit lungs

1995 ◽  
Vol 78 (4) ◽  
pp. 1502-1508 ◽  
Author(s):  
R. Spriestersbach ◽  
F. Grimminger ◽  
N. Weissmann ◽  
D. Walmrath ◽  
W. Seeger

In buffer-perfused rabbit lungs, the mixed expired gas was continuously analyzed for nitric oxide (NO) by chemiluminescence detection, and recovery data in dependency of the alveolar O2 tension were established. A small aliquot of the lung effluent was continuously forwarded to a reaction vessel in which the NO decomposition products nitrite, peroxynitrite, and nitrate [summarized as NOx; acidic vanadium (III) chloride reagent] or nitrite (acidic sodium iodide reagent) were quantitatively reduced back to NO, which was then transferred to a second chemiluminescence detector. Under baseline conditions, the perfused lungs continuously released 2.2 +/- 0.21 nmol/min of NO (n = 10) into the gas space. NO was permanently liberated into the intravascular compartment at 7.0 +/- 0.3 nmol/min (n = 4). According to a very low buffer-gas partition coefficient of NO (estimated to be 0.0292 +/- 0.005 in separate equilibration experiments), NO aerated into the prelung perfusate largely escaped into the alveolar space within one lung passage, whereas only low percentages of inhaled NO were detected as NOx in the buffer medium. Immediate increase of lung NO generation in response to A-23187 challenge and inhibition by NG-monomethyl-L-arginine were demonstrated. In conclusion, in buffer-perfused lungs, total NO generation may be monitored by continuous analysis of NO exhalation and perfusate NOx accumulation.

Author(s):  
John F. Mansfield ◽  
Douglas C. Crawford

A method has been developed that allows on-line measurement of the thickness of crystalline materials in the analytical electron microscope. Two-beam convergent beam electron diffraction (CBED) patterns are digitized from a JEOL 2000FX electron microscope into an Apple Macintosh II microcomputer via a Gatan #673 CCD Video Camera and an Imaging Systems Technology Video 1000 frame-capture board. It is necessary to know the lattice parameters of the sample since measurements are made of the spacing of the diffraction discs in order to calibrate the pattern. The sample thickness is calculated from measurements of the spacings of the fringes that are seen in the diffraction discs. This technique was pioneered by Kelly et al, who used the two-beam dynamic theory of MacGillavry relate the deviation parameter (Si) of the ith fringe from the exact Bragg condition to the specimen thickness (t) with the equation:Where ξg, is the extinction distance for that reflection and ni is an integer.


1993 ◽  
Vol 28 (11-12) ◽  
pp. 531-538 ◽  
Author(s):  
B. Teichgräber

A nitrification/denitrification process was applied to reject water treatment from sludge dewatering at Bottrop central sludge treatment facilities of the Emschergenossenschaft. On-line monitoring of influent and effluent turbidity, closed loop control of DO and pH, and on-line monitoring of nitrogen compounds were combined to a three level control pattern. Though on-line measurement of substrate and product showed substantial response time it could be used to operate nitrification/denitrification within process boundaries.


Author(s):  
Qiwen Jin ◽  
Xijiong Chen ◽  
Pei Li ◽  
Yonggang Zhou ◽  
Yingchun Wu ◽  
...  

Children ◽  
2021 ◽  
Vol 8 (5) ◽  
pp. 378
Author(s):  
Satyan Lakshminrusimha ◽  
Sylvia F. Gugino ◽  
Krishnamurthy Sekar ◽  
Stephen Wedgwood ◽  
Carmon Koenigsknecht ◽  
...  

Resuscitation with 21% O2 may not achieve target oxygenation in preterm infants and in neonates with persistent pulmonary hypertension of the newborn (PPHN). Inhaled nitric oxide (iNO) at birth can reduce pulmonary vascular resistance (PVR) and improve PaO2. We studied the effect of iNO on oxygenation and changes in PVR in preterm lambs with and without PPHN during resuscitation and stabilization at birth. Preterm lambs with and without PPHN (induced by antenatal ductal ligation) were delivered at 134 d gestation (term is 147–150 d). Lambs without PPHN were ventilated with 21% O2, titrated O2 to maintain target oxygenation or 21% O2 + iNO (20 ppm) at birth for 30 min. Preterm lambs with PPHN were ventilated with 50% O2, titrated O2 or 50% O2 + iNO. Resuscitation with 21% O2 in preterm lambs and 50%O2 in PPHN lambs did not achieve target oxygenation. Inhaled NO significantly decreased PVR in all lambs and increased PaO2 in preterm lambs ventilated with 21% O2 similar to that achieved by titrated O2 (41 ± 9% at 30 min). Inhaled NO increased PaO2 to 45 ± 13, 45 ± 20 and 76 ± 11 mmHg with 50% O2, titrated O2 up to 100% and 50% O2 + iNO, respectively, in PPHN lambs. We concluded that iNO at birth reduces PVR and FiO2 required to achieve target PaO2.


2006 ◽  
Author(s):  
Yongcai Yang ◽  
Junsan Ma ◽  
Rimin Pan ◽  
Xiang Yu

1994 ◽  
Vol 26 (3) ◽  
pp. 407-411 ◽  
Author(s):  
P. Benoit ◽  
Choné Th. ◽  
E. Barriuso

Sign in / Sign up

Export Citation Format

Share Document