Regional measurement of canine skeletal muscle blood flow by positron emission tomography with H2 15O

2002 ◽  
Vol 92 (4) ◽  
pp. 1709-1716 ◽  
Author(s):  
Alan J. Fischman ◽  
Hongbing Hsu ◽  
Edward A. Carter ◽  
Yong M. Yu ◽  
Ronald G. Tompkins ◽  
...  

Positron emission tomography (PET) with H2 15O was used as an in vivo, relatively noninvasive, quantitative method for measuring regional blood flow to hindlimb skeletal muscle of anesthetized dogs. A hydrooccluder positioned on the femoral artery was used to reduce flow, and high-flow states were produced by local infusion of adenosine. Three to four measurements were made in each animal. Approximately 40 mCi of H2 15O were injected intravenously, and serial images and arterial blood samples were acquired over 2.5 min. Data analysis was performed by fitting tissue and arterial blood time-activity curves to a modified, single-compartment Kety model. The model equation was also solved on a pixel-by-pixel basis to yield maps of regional skeletal muscle blood flow. After each PET determination, flow was measured with radioactive microspheres. Results of the PET measurements demonstrated that basal flow to hindlimb skeletal muscle was 3.83 ± 0.36 ml · min−1 · 100 g−1(mean ± SE). This value was in excellent agreement with the microsphere data, 3.73 ± 0.32 ml · min−1 · 100 g−1( P = 0.69, not significant). Adenosine infusion resulted in flows as high as 30 ml · min−1 · 100 g−1, and the PET and microsphere data were highly correlated over the entire range of flows ( r 2 = 0.98, P < 0.0001). We conclude that muscle blood flow can be accurately measured in vivo by PET with H2 15O and that this approach offers promise for application in human studies of muscle metabolism under varying pathophysiological states.

1995 ◽  
Vol 15 (5) ◽  
pp. 787-797 ◽  
Author(s):  
B. Sadzot ◽  
C. Lemaire ◽  
P. Maquet ◽  
E. Salmon ◽  
A. Plenevaux ◽  
...  

Changes in serotonin-2 receptors have been demonstrated in brain autopsy material from patients with various neurodegenerative and affective disorders. It would be desirable to locate a ligand for the study of these receptors in vivo with positron emission tomography (PET). Altanserin is a 4-benzoylpiperidine derivative with a high affinity and selectivity for S2 receptors in vitro. Dynamic PET studies were carried out in nine normal volunteers with high-specific activity (376–1,680 mCi/μmol) [18F]altanserin. Arterial blood samples were obtained and the plasma time–activity curves were corrected for the presence of labeled metabolites. Thirty minutes after injection, selective retention of the radioligand was observed in cortical areas, while the cerebellum, caudate, and thalamus had low radioactivity levels. Specific binding reached a plateau between 30 and 65 min postinjection at 1.8% of the injected dose/L of brain and then decreased, indicating the reversibility of the binding. The total/nonspecific binding ratio reached 2.6 for times between 50 and 70 min postinjection. The graphical analysis proposed by Logan et al. allowed us to estimate the binding potential ( Bmax/ KD). Pretreatment with ketanserin was given to three volunteers and brain activity remained uniformly low. An additional study in one volunteer showed that [18F]altanserin can be displaced from the receptors by large doses of ketanserin. At the end of the study, unchanged altanserin was 57% of the total plasma activity. These results suggest that [18F]altanserin is selective for S2 receptors in vivo as it is in vitro. They indicate that [18F]altanserin is suitable for imaging and quantifying S2 receptors with PET in humans.


1991 ◽  
Vol 11 (6) ◽  
pp. 926-931 ◽  
Author(s):  
M. Ingvar ◽  
L. Eriksson ◽  
G. A. Rogers ◽  
S. Stone-Elander ◽  
L. Widén

The development of methods for production of a radiotracer for use in human studies with positron emission tomography (PET) is often a time-consuming process of optimizing radiolabelling yields and handling procedures. Sometimes the radiotracer is not the original drug, but rather a derivative with unknown in vivo pharmacological properties. We have developed a fast and simple method of testing putative new PET tracers in vivo in small animals. The procedure has been validated in rats with different PET tracers with known kinetic and pharmacological properties ([2-18F]2-fluoro-2-deoxy-d-glucose, [ N-methyl-11C]Ro 15-1788, and [15O]butanol). The tracer concentration in arterial blood was continuously measured to obtain the brain input function. Following image reconstruction of the scans, time–activity curves of selected regions of interest were generated. Estimations of CMRglc (1.0 ± 0.2 μmol g−1 min−1), CBF (1.4 ± 0.4 ml g−1 min−1) and transport rate constants for [ N-methyl-11C]Ro 15-1788 (K1 = 0.44 ± 0.01 ml g−1 min−1 and k2 = 0.099 ± 0.005 min−1) as well as calculated first pass extraction (0.32 ±0.1) are in reasonable agreement with literature values. Small animal studies require minimal amounts of radioactivity and can be performed without sterility and toxicology tests. They may serve as a preliminary basis for radiation safety calculations because whole body scans can be performed even with a head scanner. The major advantage of this procedure in comparison to ex vivo autoradiography is that very few experiments are necessary to reliably determine the properties of the blood–brain barrier transport of the radiotracer and the possible whole brain receptor binding characteristics.


2018 ◽  
Vol 1 (1) ◽  
Author(s):  
Ilkka Heinonen ◽  
Kari Kalliokoski ◽  
Vesa Oikonen ◽  
Christopher Mawhinney ◽  
Warren Gregson ◽  
...  

Objective Skeletal muscle is unique among organs in that its blood flow, thus oxygen supply that is critical for muscular function, can change over a remarkably large range. Compared to the rest, muscle blood flow can increase over 20-fold during intense exercise. Positron emission tomography (PET) and [15O]-H2O tracer provide a unique tool for the direct measurement of muscle blood flow in specific muscle regions. Quantification of PET blood flow requires knowledge of the arterial input function, which is usually provided by arterial blood sampling. However, arterial sampling is an invasive approach requiring arterial cannulation. In the current study, we aimed to explore the analysis and error estimation based on non-invasive, PET image-based input function for skeletal muscle blood flow in PET [15O]-labeled radiowater study. Methods Thirty healthy untrained men volunteered to participate in this study. [15O]-labeled radio water PET perfusion scans were performed at rest and right after cycling exercise. GE Discovery PET-CT scanner was used for image acquisition. The 15O isotope was produced with a Cyclone 3 cyclotron (IBA Molecular, Belgium). After 455 MBq of 15O-H2O was injected intravenously and after 20 seconds, dynamic scanning images were performed in following frames: 6x5 seconds, 12x10 seconds, 7x30 seconds and 12x10 seconds. Arterial blood was sampled continuously from radial artery during imaging for radioactivity with a detector during PET scanning. All the data analysis was performed using all in-house developed programs. Arterial input function was preprocessed with delay correction. Image-based input function was defined based on sum image of dynamic images. Blood flow was calculated using the 1-tissue compartment model, k1 is considered as blood flow without any further correction. All data analysis was performed by Carimas software (http://www.turkupetcentre.fi/carimas). Data analysis was performed in five parts: 1) Modelling data using input function from artery. 2) By defining femoral artery Volume Of Interest (VOI) on PET images. 3) Modelling data using image-based input function. 4) Calculating the correlation for blood flow between artery (blood) input function and image-based input function. 5) Predicted true blood flow was calculated based on correlation based on the initial linear relationship between blood and image-based input functions. Results Skeletal muscle blood flow had a good linear relationship calculated by femoral artery VOI and by arterial (blood) input function (y = 2,9587x - 0,096, R² = 0,8852, p<0.0001). Further, by using the prediction equation obtained by the linear relationship between VOI-determined (femoral) artery blood flow and direct gold standard (radial) artery input function determined blood flow, image-based input function determined blood flow was well predicted using this non-invasive approach (y = 1,1812x + 0,1219, R² = 0,9259, p<0.0001). Conclusions It is concluded that there is a strong linear correlation between gold standard invasive approach and non-invasive image-based approach to measure skeletal muscle blood flow by PET, but if no further corrections are made, image-based approach overestimates correct blood flow. However, this can be corrected by linear prediction equation, suggesting that invasive arterial input function may not always be needed in the future when measuring skeletal muscle blood flow by PET. This will be of benefit particularly for exercise studies.


1982 ◽  
Vol 2 (1) ◽  
pp. 89-98 ◽  
Author(s):  
Myron D. Ginsberg ◽  
Alan H. Lockwood ◽  
Raul Busto ◽  
Ronald D. Finn ◽  
Cathy M. Butler ◽  
...  

A simplified mathematical model is described for the measurement of regional cerebral blood flow by positron emission tomography in man, based on a modification of the autoradiographic strategy originally developed for experimental animal studies. A modified ramp intravenous infusion of radiolabeled tracer is used; this results in a monotonically increasing curvilinear arterial activity curve that may be accurately described by a polynomial of low degree (= z). Integrated cranial activity C̄ B is measured in regions of interest during the latter portion of the tracer infusion period (times T1 to T2). It is shown that [Formula: see text] where each of the terms A x is a readily evaluated function of the blood flow rate constant k, the brain:blood partition coefficient for the tracer, the cranial activity integration limits T1 and T2, the coefficients of the polynomial describing the arterial curve, and an iteration factor n that is chosen to yield the desired degree of precision. This relationship permits generation of a table of C̄ B vs. k, thus facilitating on-line computer solution for blood flow. This in vivo autoradiographic paradigm was validated in a series of rats by comparing it to the classical autoradiographic strategy developed by Kety and associates. Excellent agreement was demonstrated between blood flow values obtained by the two methods: CBF in vivo = CBFclassical X 0.99 − 0.02 (units in ml g−1 min−1; correlation coefficient r = 0.966).


2016 ◽  
Vol 36 (5) ◽  
pp. 842-861 ◽  
Author(s):  
Audrey P Fan ◽  
Hesamoddin Jahanian ◽  
Samantha J Holdsworth ◽  
Greg Zaharchuk

Noninvasive imaging of cerebral blood flow provides critical information to understand normal brain physiology as well as to identify and manage patients with neurological disorders. To date, the reference standard for cerebral blood flow measurements is considered to be positron emission tomography using injection of the [15O]-water radiotracer. Although [15O]-water has been used to study brain perfusion under normal and pathological conditions, it is not widely used in clinical settings due to the need for an on-site cyclotron, the invasive nature of arterial blood sampling, and experimental complexity. As an alternative, arterial spin labeling is a promising magnetic resonance imaging technique that magnetically labels arterial blood as it flows into the brain to map cerebral blood flow. As arterial spin labeling becomes more widely adopted in research and clinical settings, efforts have sought to standardize the method and validate its cerebral blood flow values against positron emission tomography-based cerebral blood flow measurements. The purpose of this work is to critically review studies that performed both [15O]-water positron emission tomography and arterial spin labeling to measure brain perfusion, with the aim of better understanding the accuracy and reproducibility of arterial spin labeling relative to the positron emission tomography reference standard.


2001 ◽  
Vol 25 (4) ◽  
pp. 306-312
Author(s):  
Tajinder P. Singh ◽  
Kevin Greer ◽  
Otto Muzik ◽  
Robert L. Hammond ◽  
Larry W. Stephenson ◽  
...  

2000 ◽  
Vol 83 (4-5) ◽  
pp. 395-401 ◽  
Author(s):  
Kari K. Kalliokoski ◽  
Jukka Kemppainen ◽  
Kirsti Larmola ◽  
Teemu O. Takala ◽  
Pauliina Peltoniemi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document