scholarly journals Neural ITD coding with bilateral cochlear implants: effect of binaurally coherent jitter

2012 ◽  
Vol 108 (3) ◽  
pp. 714-728 ◽  
Author(s):  
Kenneth E. Hancock ◽  
Yoojin Chung ◽  
Bertrand Delgutte

Poor sensitivity to the interaural time difference (ITD) constrains the ability of human bilateral cochlear implant users to listen in everyday noisy acoustic environments. ITD sensitivity to periodic pulse trains degrades sharply with increasing pulse rate but can be restored at high pulse rates by jittering the interpulse intervals in a binaurally coherent manner (Laback and Majdak. Binaural jitter improves interaural time-difference sensitivity of cochlear implantees at high pulse rates. Proc Natl Acad Sci USA 105: 814–817, 2008). We investigated the neural basis of the jitter effect by recording from single inferior colliculus (IC) neurons in bilaterally implanted, anesthetized cats. Neural responses to trains of biphasic pulses were measured as a function of pulse rate, jitter, and ITD. An effect of jitter on neural responses was most prominent for pulse rates above 300 pulses/s. High-rate periodic trains evoked only an onset response in most IC neurons, but introducing jitter increased ongoing firing rates in about half of these neurons. Neurons that had sustained responses to jittered high-rate pulse trains showed ITD tuning comparable with that produced by low-rate periodic pulse trains. Thus, jitter appears to improve neural ITD sensitivity by restoring sustained firing in many IC neurons. The effect of jitter on IC responses is qualitatively consistent with human psychophysics. Action potentials tended to occur reproducibly at sparse, preferred times across repeated presentations of high-rate jittered pulse trains. Spike triggered averaging of responses to jittered pulse trains revealed that firing was triggered by very short interpulse intervals. This suggests it may be possible to restore ITD sensitivity to periodic carriers by simply inserting short interpulse intervals at select times.

2008 ◽  
Vol 123 (5) ◽  
pp. 3562-3562 ◽  
Author(s):  
Matthew J. Goupell ◽  
Piotr Majdak ◽  
Bernhard Laback

2008 ◽  
Vol 100 (1) ◽  
pp. 92-107 ◽  
Author(s):  
John C. Middlebrooks

In the most commonly used cochlear prosthesis systems, temporal features of sound are signaled by amplitude modulation of constant-rate pulse trains. Several convincing arguments predict that speech reception should be optimized by use of pulse rates ≳2,000 pulses per second (pps) and by use of intracochlear electrode configurations that produce restricted current spread (e.g., bipolar rather than monopolar configurations). Neither of those predictions has been borne out in consistent improvements in speech reception. Neurons in the auditory cortex of anesthetized guinea pigs phase lock to the envelope of sine-modulated electric pulse trains presented through a cochlear implant. The present study used that animal model to quantify the effects of carrier pulse rate, electrode configuration, current level, and modulator wave shape on transmission of temporal information from a cochlear implant to the auditory cortex. Modulation sensitivity was computed using a signal-detection analysis of cortical phase-locking vector strengths. Increasing carrier pulse rate in 1-octave steps from 254 to 4,069 pps resulted in systematic decreases in sensitivity. Comparison of sine- versus square-wave modulator waveforms demonstrated that some, but not all, of the loss of modulation sensitivity at high pulse rates was a result of the decreasing size of pulse-to-pulse current steps at the higher rates. Use of a narrow bipolar electrode configuration, compared with the monopolar configuration, produced a marked decrease in modulation sensitivity. Results from this animal model suggest explanations for the failure of high pulse rates and/or bipolar electrode configurations to produce hoped-for improvements in speech reception.


2019 ◽  
Vol 43 (1) ◽  
pp. 21-25
Author(s):  
Mohammed Senna Hassan

   Twenty Iraqi ducks hearts ( 10 male and 10 female ) have been  used for   demonstration  and illustration of heart's valves  and chambers  as well as  anatomical   and morphological site of view to explain what modifications had been take place for ducks heart  to perform  his normal life at the  circumstances  of  high  blood  pressure  and  pulse  rate. The heart  which has distinctly pointed  apex  was  built   in simple  manner located  in a transparent  taught  heart  pericardial  sac. It   was pyramidal in shape  externally  and  has a longitudinal  salcus  passing  to the  right  side, the  anterior of  the   heart  is  divided  into two  unequal  anterior  chamber  similar  to  those of mammalian  hear  .The heart valves are modified  in  order to  minimize  the  fraction  that occur as a result of  high  blood  pressure  and  pulse  rate  of  the  duck  heart , also  the  muscular  trabeculae   replace  the  chordate  tendineae  , which  were  present in the  mammalian    heart  in order to  minimize  the  fraction  resulting  from high  pulse  rate..    