scholarly journals Development and Validation of a HPLC Method for Determination of Anastrozole in Tablet Dosage Form

2011 ◽  
Vol 8 (2) ◽  
pp. 794-797 ◽  
Author(s):  
D. Sathis Kumar ◽  
A. Harani ◽  
D. Sridhar ◽  
David Banji ◽  
Knv Rao ◽  
...  

A simple, economic, accurate reverse phase isocratic HPLC method was developed for the quantitation of anastrozole in tablet dosage form. The quantification was carried out using Gracesmart RP18, 5 μ (100 mmx4.6 mm) with UV detected at 215 nm. The elution was achieved isocratically with a mobile phase comprising a mixture of buffer (pH 6.0) and acetonitrile (1:1, v/v). The flow rate was 1.0 mL/min The procedure was validated as per ICH rules for Accuracy, Precision, Detection limit, Linearity, Reproducibility and Quantitation limit. The linearity concentration range was 10-20 mcg/mL with the correlation coefficient of 0.9935. The percentage recovery for Anastrozole was found to be 97.31±2.2%. Limit of detection and limit of quantitation values were found to be 0.351 mcg/mL and 1.053 mcg/mL. The method has been successfully used to analyze commercial solid dosage containing 1mg of anastrozole with good recoveries and proved to be robust.

2017 ◽  
Vol 9 (4) ◽  
pp. 76
Author(s):  
Panchumarthy Ravisankar ◽  
Shaheem Sulthana ◽  
Inturi Mary Thanuja ◽  
A. Dihitha Chowdary ◽  
J. Vyshnavi

Objective: The objective of the current study was to develop and validate a novel RP-HPLC method for determination of bamifylline hydrochloride in pharmaceutical dosage form.Methods: Chromatographic separation was conducted on Agilent technologies-1260 series with the G1311C quaternary pump, eclipse XDB C18 column (4.6 mm i.d. X 250 mm, 5 µm particle sizes) and equipped with photodiode array detector G1315D. Mobile phase consisted of methanol and acetonitrile were mixed in the ratio of 90:10 v/v, was used at a flow rate of 1 ml/min and detection wavelength was set at 263 nm.Results: The retention time for bamifylline hydrochloride was found to be 2.913 min. The calibration was linear (r2= 0.9996) in the concentration range of 2-10 µg/ml. The limit of detection and the limit of quantitation were found to be 0.4825 μg/ml and 1.4621 µg/ml respectively. Recovery of bamifylline hydrochloride in tablet formulation was observed in the range of 99.6-99.8 %. Percentage assay of bamifylline hydrochloride (Bamifix) was found to be 99.4 % w/w.Conclusion: Thus the novel proposed method for bamifylline hydrochloride was found to be feasible for the estimation of bamifylline hydrochloride in bulk as well as a pharmaceutical dosage form. 


2019 ◽  
Vol 31 (5) ◽  
pp. 1002-1008
Author(s):  
Somana Siva Prasad ◽  
G.V. Krishna Mohan ◽  
A. Naga Babu

A novel reversed-phase high performance liquid chromatographic (HPLC) technique for the determination of everolimus (Isomer-B) and its impurities in the tablet dosage form has been optimized using analytical quality by design (QbD) approach. All the compounds are monitored with the photodiode array (PDA) detector at 280 nm and the parameters namely; precision, accuracy, specificity, stability, linearity, limit of quantitation (LOQ) and limit of detection (LOD) are evaluated. The quantitation limits of IMP-A, IMP-B, IMP-C, IMP-D, IMP-E, Sirolimus and TGR are found to be 0.08, 0.08, 0.10, 0.10, 0.10, 0.08 and 0.08, respectively. Recovery studies from 0.9 mg/L to 9.0 mg/L are performed for all impurities and the values were obtained between 85-110 %. Injection volume and test concentrations have been optimized to achieve LOQ values under the reporting threshold. The whole technique is developed and validated as per International Council for Harmonization (ICH) guidelines. The proposed method is robust, sensitive, rapid and successful and helpful in the regions where regulatory agencies recommend HPLC analytical method.


Author(s):  
R. Anantha Kumar ◽  
G. Raveendr Babu ◽  
Sowjanya M. ◽  
Ramayyappa M.

The aim of this work is to build up a fast, exact, precise and touchy reverse phase liquid chromatographic method for the synchronous assessment of amiloride and hydrochlorothiazide in tablet dose structure. The chromatographic strategy was normalized utilizing Hypersil ODS segment (250×4.6mm, 5μm molecule size) with UV discovery at 210nm and stream pace of 1ml/min. The portable stage includes phosphate buffer (pH acclimated to 2.5 with dilute Ortho Phosphoric acid) and acetonitrile in the proportion of 60:40 v/v. The linearity of proposed technique was examined in the scope of 5-30μg/ml (R²=0.999) for amiloride and 50-300μg/ml (R²=0.999) for Hydrochlorothiazide appropriately. The limit of detection (LOD) was discovered to be 0.10μg/ml and 0.40μg/ml for Amiloride and Hydrochlorothiazide appropriately. The limit of quantitation (LOQ) was discovered to be 0.30μg/ml and 1.20μg/ml for Amiloride and Hydrochlorothiazide separately. The retention times of Amiloride and Hydrochlorothiazide were found to be 3.258min and 2.383min separately. The technique was truly recommended and %RSD was found to be under 2 demonstrating serious level of exactness and accuracy. Subsequently proposed strategy can be effectively evaluated for the synchronous assessment of Amiloride and Hydrochlorothiazide in promoted formulations.


2016 ◽  
Vol 20 ◽  
pp. S328-S333 ◽  
Author(s):  
Jaiprakash N. Sangshetti ◽  
Mohammed Aqeel ◽  
Zahid Zaheer ◽  
Rana Z. Ahmed ◽  
M.H.G. Dehghan ◽  
...  

2019 ◽  
Vol 15 (3) ◽  
pp. 243-250 ◽  
Author(s):  
Surendra Agrawal ◽  
Pravina Gurjar ◽  
Bhavik Katheriya

Introduction: Trimetazidine and Metoprolol combination is more effective in the treatment of cardiac disorders as compared to single drug therapy.Background: Materials and Methods: A rapid, simple, and sensitive HPTLC method was developed for the simultaneous determination of Trimetazidine and metoprolol from its tablet dosage form and validated. In HPTLC method, standard and sample solutions of Trimetazidine hydrochloride and metoprolol succinate were applied on pre-coated silica gel G 60 F254 TLC plate, and developed by using mobile phase, n-butanol :water: methanol: ammonia as solvent (8.5:0.1:0.1: 0.85, v/v). The drugs on plate were scanned at 213 nm. The method produced compact and well-resolved bands at Rf of 0.32 ± 0.02 and 0.66 ± 0.02 for Trimetazidine Hydrochloride and Metoprolol succinate respectively. The range for linearity was observed as 500-2500 ng band-1 for Trimetazidine hydrochloride and 500-2500 ng band-1 for metoprolol succinate and correlation coefficient were 0.9991 and 0.9997 respectively. Conclusion: The developed method was validated according to the ICH guidelines for precision, accuracy, Limit of detection, Limit of quantitation, specificity and robustness. The method was checked for suitability in determination of Trimetazidine hydrochloride and Metoprolol succinate in their tablet dosage form. The assay result was found to be 99.64 % ± 0.45 and 99.94 % ± 0.53 of percentage label claim for Trimetazidine hydrochloride and Metoprolol succinate respectively.


Author(s):  
Krishna Kishore Adireddy ◽  
Srinivasa Rao Baratam ◽  
Nagarjuna Hari Pratap S

A simple, rapid, accurate and precise RP-HPLC method was developed and validated for the determination of Istradefylline in table dosage form. Chromatographic analysis of the drug was achieved on Shimadzu HPLC comprising of LC- 20 AD binary gradient pump, a variable wavelength programmable SPD-20A detector and SCL system controller. C18G column (250 mm x 4.6 mm, 5 μ) as stationary phase with mobile phase consisting of 0.1 % orthophosphoric acid and acetonitrile in the ratio of 30: 70 v/v. The method showed a good linear response in the concentration range of 10-90 μg/ml with correlation coefficient of 0.9993. The flow rate was maintained at 1.0 ml/min and detection was carried out at 246 nm. The retention time was 3.125 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, solution stability, selectivity and sensitivity. The results obtained in the study were within the limits of ICH guidelines and hence this method can be used for the determination of istradefylline in tablet formulation.


2018 ◽  
Vol 5 (1) ◽  
pp. 1-4
Author(s):  
Devi Velmurugan ◽  
Jambulingam Munusamy ◽  
Ananda Thangadurai Subramaniam ◽  
Anandkumar Karunakaran ◽  
Abdul Latiff MKM ◽  
...  

In the present study we are reporting  dissolution, method development and validation of water soluble vitamins B1, B2 & B6 in bulk and tablet dosage form by HPTLC method. The method is based on separation of the three vitamins using HPTLC. Thin layer chromatographic plates coated with silica gel 60F254 as the stationary phase and acetonitrile:water (6:4 v/v) as mobile phase. The chromatographic analysis was carried out in the reflectance and absorbance mode at 280 nm. The method was validated with respect to linearity, accuracy and precision, limit of detection and limit of quantitation. It was then applied for analysis of vitamins B1, B2 & B6 in combined tablet dosage form. The above method developed was reproducible with good resolution and the results of analysis have been validated with correlation coefficient of 0.9990


Author(s):  
MALATHI SELLAPPAN ◽  
DARTHI DEVAKUMAR

Objective: The objective of the study was to develop a simple and rapid chromatographic method for quantification of escitalopram oxalate and flupentixol dihydrochloride in combined dosage form and plasma. Methods: The separation was achieved with a sun fire C8 [150×4.6 mm] 3.5 µm column with an isocratic mobile phase containing a mixture of potassium dihydrogen orthophosphate buffer: methanol: acetonitrile [30:60:10 v/v/v] pH adjusted to 11. The flow rate of the mobile phase was 1.5 ml/min with a Photodiode array [PDA] detection at 230 nm. Results: The HPLC method was developed and validated with respective linearity, accuracy, and precision, detection of limit, robustness, and specificity. The precision of the results stated as the relative standard deviation was below 2 %. The calibration curve was linear over a concentration range from 10-50 µg/ml for escitalopram oxalate and 1-5 µg/ml for flupentixol dihydrochloride with a correlation co-efficient 0.994 and 0.977 respectively. The accuracy of the method was demonstrated at levels in the range of 100 % and 120 % of the specification limit. The recovery of escitalopram oxalate and flupentixol dihydrochloride was found to be in the range of 90 % to 88 %, respectively. The lowest detection limits were found to be 2 µg/ml for escitalopram oxalate and 0.1 µg/ml for flupentixol dihydrochloride. The lowest quantification limits were found to be 5 µg/ml of escitalopram oxalate and 0.5 µg/ml of flupentixol dihydrochloride. Conclusion: The developed method was validated for linearity, accuracy, precision, the limit of detection and quantification, specificity. The method was applied successfully for the determination of escitalopram oxalate and flupentixol dihydrochloride in the combined dosage form and plasma.


Sign in / Sign up

Export Citation Format

Share Document