scholarly journals Development of Simple and Robust RP-HPLC Method for Determination of Everolimus and its Impurities in Oral Solid Dosage Form

2019 ◽  
Vol 31 (5) ◽  
pp. 1002-1008
Author(s):  
Somana Siva Prasad ◽  
G.V. Krishna Mohan ◽  
A. Naga Babu

A novel reversed-phase high performance liquid chromatographic (HPLC) technique for the determination of everolimus (Isomer-B) and its impurities in the tablet dosage form has been optimized using analytical quality by design (QbD) approach. All the compounds are monitored with the photodiode array (PDA) detector at 280 nm and the parameters namely; precision, accuracy, specificity, stability, linearity, limit of quantitation (LOQ) and limit of detection (LOD) are evaluated. The quantitation limits of IMP-A, IMP-B, IMP-C, IMP-D, IMP-E, Sirolimus and TGR are found to be 0.08, 0.08, 0.10, 0.10, 0.10, 0.08 and 0.08, respectively. Recovery studies from 0.9 mg/L to 9.0 mg/L are performed for all impurities and the values were obtained between 85-110 %. Injection volume and test concentrations have been optimized to achieve LOQ values under the reporting threshold. The whole technique is developed and validated as per International Council for Harmonization (ICH) guidelines. The proposed method is robust, sensitive, rapid and successful and helpful in the regions where regulatory agencies recommend HPLC analytical method.

2012 ◽  
Vol 10 (2) ◽  
pp. 67-70
Author(s):  
Abdullah Al Masud ◽  
Mohammad Saydur Rahman ◽  
Towfika Islam ◽  
Saki Sultana ◽  
Moynul Hasan ◽  
...  

A simple, reproducible and efficient reversed phase high performance liquid chromatographic (RPHPLC) method has been developed for the estimation of a recently approved anti allergic drug, amlexanox in oral paste dosage form. The separations were carried out on a Zorbax Eclipse XBD, C18 column (150 x 4.6 mm; 5?m) at a flow rate of 1.50 ml/min. by using mobile phase comprising of mixed buffer (pH adjusted to 6.50) and methanol (50:50 v/v). The injection volume was 10 ?l and the peaks were detected at 244 nm. The linear dynamic range found to be in the concentration range of 15-35 ?g/ml and coefficient of correlation was found to be 0.999. The %RSD value was below 2.0 for intra-day and inter-day precision which indicated that the method was highly precise. The LOD (Limit of detection) and LOQ (Limit of quantitation) were found to be 3.8 ng/ml and 12.5 ng/ml, respectively which revealed that the method was highly sensitive. The percentage recovery of amlexanox ranged from 99.31 to 99.75%, indicating the accuracy of the method and absence of interference from the excipients present in the formulation. The proposed method was simple, fast, accurate and reproducible and hence can be applied for routine quality control operations of amlexanox in oral paste dosage form. Key words: Amlexanox, Anti allergic, RP-HPLC, LOD, LOQ. DOI: http://dx.doi.org/10.3329/dujps.v10i2.11782 Dhaka Univ. J. Pharm. Sci. 10(2): 67-70, 2011 (December)


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (06) ◽  
pp. 63-68
Author(s):  
R. Raut ◽  
◽  
A. Patil ◽  
V. K Munipalli ◽  
M. Patel ◽  
...  

A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.


Author(s):  
Sunkara Namratha ◽  
Vijayalakshmi A

Objective: Reversed-phase high-performance liquid chromatographic method (RP-HPLC) was developed for the assessment of lopinavir in the dosage form of tablet.Methods: Chromatogram was run through using Kromosil C18 4.5×150 mm using a mobile phase methanol: water of ratio 65:35% v/v with a rate of flow of 0.8 ml/min, measured by UV spectrometric detection at 265 nm. The method developed was validated in terms of precision, accuracy, linearity, and robustness parameters.Results: Retention time of lopinavir established at 2.482 min and percentage R.S.D of lopinavir found to be 1.0% and 0.5%, respectively. The method shows that good linearity range of 30–150 μg correlation coefficient of lopinavir was 0.997. The limit of detection was 2.97 and limit of quantification was 9.92, respectively. The percent purity of lopinavir was 99.87%.Conclusion: The suggested method (Rp-HPLC) for concurrent assay lopinavir was validated, which is appropriate method for the analysis oflopinavir quantitatively in tablet dosage forms and bulk.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (01) ◽  
pp. 76-78
Author(s):  
Kailasa Mangasree ◽  
◽  
Biswabara Roy ◽  
Harunrasheed Shaik ◽  
Manjunath S. Yalagatti ◽  
...  

A reverse phase high performance liquid chromatographic method was developed for simultaneous estimation of gemcitabine and clarithromycin in bulk and tablet dosage form. The method was developed by using acetonitrile: methanol: 50 mM sodium acetate buffer (adjusted to pH-3 with orthophosphoric acid (40:40:20) as a mobile phase at the flow rate of 1mL/min. The retention time was found to be 2.365 and 5.999 minutes, respectively. The method showed linearity in the concentration range 10-50 µg/mL in respect of both drugs. The % RSD was less than 0.4% for gemcitabine and 0.2% for clarithromycin. Mean percentage recovery was found to be 99.63 and 99.69 for gemcitabine and clarithromycin. The tailing factor for gemcitabine and clarithromycin was not less than 0.9 and not more than 1.4 during the robustness study. The average percentage assay was calculated and found to be 99.83 for gemcitabine and 98.89 for charithromycin. The limit of detection and quantification for gemcitabine was found to be 0.41 and 1.79 µg/mL. For Clarithromycin, the value was 0.58 and 1.37 µg/mL respectively.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (02) ◽  
pp. 39-46
Author(s):  
Babu D. China ◽  
◽  
C. Madhusudhana Chetty ◽  
Sk. Mastanamma

A simple, accurate, precise and robust reversed phase high performance liquid chromatographic (RP-HPLC) method was developed for the estimation of Ertugliflozin (ETZ) and metformin (MFN) in bulk and in tablet dosage form. The method was carried out by used Waters (5μm, C18 250 x 4.6 mm) column with mobile phase consists of 0.75 mM sodium dihydrogen orthophosphate buffer pH adjusted to 8.5, with NaOH, and acetonitrile in the ratio of 60:40 v/v, a flow rate of 1.5 mL/min and photodiode detection at 263 nm. The method was validated as per ICH guidelines with different parameters, the mean retention times of ertugliflozin and metformin were found to be 3.5& 2.0 min, respectively. The correlation coefficient values of calibration curves were found to be 0.999 for both ETZ and MFN, respectively. The LOD and LOQ for ertugliflozin and metformin were found to be 0.02-0.06 μg/mL and 17.5-58.3 μg/mL respectively.


2008 ◽  
Vol 91 (2) ◽  
pp. 344-348 ◽  
Author(s):  
Shweta Sadanand Sabnis ◽  
Nilesh Dnvandev Dhavale ◽  
Vijay Yeshawantrao Jadhav ◽  
Santosh Vilashchand Gandhi

Abstract A new, simple column reversed-phase high-performance liquid chromatographic (HPLC) method for simultaneous determination of rabeprazole sodium (RAB) and domperidone (DOM) in a combined tablet dosage form has been developed and validated. Determination was performed using a Jasco HPLC system with a HiQ SiL octadecylsilane (C18) column (250 4.6 mm id), acetonitrile0.1 M ammonium acetate (50 + 50, v/v) mobile phase, and paracetamol as an internal standard. The detection was performed using a UV detector set at 280 nm. The method was validated with respect to linearity, accuracy, precision, and robustness. Beer's law was obeyed in the concentration range of 1.010.0 and 0.55.0 g/mL for RAB and DOM, respectively. The method has been successfully applied for the analysis of drugs in a pharmaceutical formulation.


2010 ◽  
Vol 7 (3) ◽  
pp. 827-832 ◽  
Author(s):  
R. Kalaichelvi ◽  
B. Thangabalan ◽  
D. Srinivasa Rao

A rapid, simple and validated reversed-phase high-performance liquid chromatographic method has been developed for analysis of aripiprazole in tablet dosage form. Aripiprazole was separated on an ODS analytical column with a 40:60 (v/v) mixture of acetonitrile and triethanolamine buffer (5 mM, pH 3.5 ± 0.05 adjusted by addition of 85% phosphoric acid) as mobile phase at a flow rate of 1.5 mL min-1. The effluent was monitored by UV detection at 254 nm. Calibration plots were linear in the range of 20 to 60 µg mL-1and the LOD and LOQ were 0.411 and 1.248 µg mL-1, respectively. The high recovery and low relative standard deviation confirm the suitability of the method for routine quality control determination of aripiprazole in tablets.


2021 ◽  
Vol 9 (2) ◽  
Author(s):  
Darinka Brodnjak Vončina ◽  
Maša Islamčivic Razboršek ◽  
Marjana Simonič

The aim of this study was to develop a method for identification and quantification of phenolic acids in different wine samples. The simple reversed-phase HPLC-UV method for simultaneous determination of p-coumaric and ferulic acid was developed. The method was validated and working range, linearity, repeatability, accuracy, limit of quantitation LOQ and limit of detection LOD were determined. The linearity of the method was tested in concentration ranges 0.1-1 mg L-1 and 1-10 mg L-1. The correlation coefficients (r2) were greater than 0.996 and quality coefficients (QC) ≤ 5%. Detection limit for both compounds was 0.01 mg L-1. The method is precise (RSD


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (03) ◽  
pp. 39-45
Author(s):  
A Sherje ◽  
A. Sonalkar ◽  

A reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of olmesartan medoxomil (OLME) and chlorthalidone (CHLOR) in tablet dosage form. The analysis was performed on Inertsil ODS C18 (250 x 4.6 mm, 5 μ) using KH2PO4 phosphate buffer (pH) and acetonitrile as mobile phase in the proportion of 60: 40 v/v at flow rate of 1.0 mL/min. Detection of drugs was carried out in isocratic mode using UV detector at 275 nm. The retention time of OLME and CHLOR was 13.9 ± 0.1 min. and 4.4 ± 0.5 min., respectively and the total run time was 20 min. The method was validated according to the requirements of the United States Pharmacopeia. The percentage recoveries was found to be in the range of 98.9 - 100.7%. The method was successfully applied to the assay of OLME and CHLOR in tablet dosage form.


Sign in / Sign up

Export Citation Format

Share Document