scholarly journals Validated LC Method for the Estimation of Dorzolamide HCl (Carbonic Anhydrase Inhibitor) in Ophthalmic Solutions

2012 ◽  
Vol 9 (3) ◽  
pp. 1238-1243 ◽  
Author(s):  
A. Narendra ◽  
D. Deepika ◽  
M. Mathrusri Annapurna

A reverse phase HPLC method is described for the determination of Dorzolamide in eye drops. Chromatography was carried on an Inertsil ODS 3V column using Acetonitrile : (0.02M) 1,Octane Sulphonic acid buffer (pH 3.5) (36:64 v/v) on isocratic mode at a flow rate of 1 mL/min with UV detection at 254 nm. The detector response was linear in the concentration range 4-720 µg/mL. The limit of detection and limit of quantification are found to be 0.7041 and 2.3483 µg/mL respectively. The method was validated as per the ICH guidelines. The proposed method is rapid, accurate and precise and can be applied for the routine analysis of dorzolamide in ophthalimic solutions.

2010 ◽  
Vol 7 (3) ◽  
pp. 807-812 ◽  
Author(s):  
Vanita Somasekhar ◽  
D. Gowri Sankar

A reverse phase HPLC method is described for the determination of esmolol hydrochloride in bulk and injections. Chromatography was carried on a C18column using a mixture of acetonitrile, 0.05 M sodium acetate buffer and glacial acetic acid (35:65:3 v/v/v) as the mobile phase at a flow rate of 1 mL/min with detection at 275 nm. The retention time of the drug was 4.76 min. The detector response was linear in the concentration of 1-50 μg/mL. The limit of detection and limit of quantification was 0.614 and 1.86 μg/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of esmolol hydrochloride in bulk and injections.


2012 ◽  
Vol 9 (3) ◽  
pp. 1327-1331 ◽  
Author(s):  
A. Narendra ◽  
D. Deepika ◽  
M. Mathrusri Annapurna

A reverse phase LC method was developed for the determination of Brimonidine in eye drops. Chromatography was carried on an Inertsil ODS 3V column (C18) using a mixture of Octane 1- sulfonic acid sodium salt (0.02M) (pH 3.5 ± 0.05) and acetonitrile (64:36 v/v) as mobile phase at a flow rate of 1 mL/min with UV detection at 254 nm. The drug was eluted at 4.636 min. The detector response was linear in the concentration range of 0.4–72 μg/mL. The limit of detection and limit of quantification were found to be 0.0561 and 0.1848 μg/mL respectively. The proposed method was validated as per the ICH guidelines and can be applied for the routine analysis of Brimonidine in eye drops.


2007 ◽  
Vol 4 (3) ◽  
pp. 302-306 ◽  
Author(s):  
K. Vanitha Prakash ◽  
J. Venkateswara Rao ◽  
N. Appala Raju

A reverse phase HPLC method is described for the determination of Nelfinavir Mesylate in tablet dosage form. Chromatography was carried on an ODS column using a mixture of acetonitrile and phosphate buffer pH 6 (90:10v/v) as the mobile phase at a flow rate of 1.2 mL/min with detection at 230 nm. The retention time of the drug was 6.68 min. The detector response was linear in the concentration of 1-20 mcg/mL. The limit of detection and limit of quantification was 1.0 and 10.0 mcg/ mL respectively. The percentage assay of Nelfinavir Mesylate was 99.77 %. The method was validated by determining its sensitivity, accuracy and precision. The proposed method is simple, fast, accurate and precise and hence can be applied for routine quality control of Nelfinavir Mesylate in bulk and tablet dosage form.


2014 ◽  
Vol 50 (4) ◽  
pp. 793-797 ◽  
Author(s):  
Vanita Somasekhar

A reverse phase HPLC method is described for the determination of 6-mercaptopurine in bulk and tablets. Chromatography was carried on a C18 column using a mixture of acetonitrile and 0.05 mol/L sodium acetate buffer (10:90 v/v) as the mobile phase at a flow rate of 1 mL/min-1 with detection at 324 nm. The retention time of the drug was 3.25 min. The detector response was linear in the concentration of 0.01-5 μg/mL. The limit of detection and limit of quantification were 17 and 52 ng/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of mercaptopurine in bulk and tablets.


2009 ◽  
Vol 6 (3) ◽  
pp. 915-919 ◽  
Author(s):  
M. K. Sahoo ◽  
R. K. Giri ◽  
C. S. Barik ◽  
S. K. Kanungo ◽  
B. V. V. Ravi Kumar

A reverse phase HPLC method is described for the determination of nebivolol in tablet dosage form. Chromatography was carried on a Hypersil ODS C18column using a mixture of methanol and water (80:20 v/v) as the mobile phase at a flow rate of 1.0 mL/min with detection at 282 nm. Chlorzoxazone was used as the internal standard. The retention times were 3.175 min and 4.158 min for nebivolol and chlorzoxazone respectively. The detector response was linear in the concentration of 1-400 μg/mL. The limit of detection and limit of quantification was 0.0779 and 0.2361 μg/mL respectively. The percentage assay of nebivolol was 99.974%. The method was validated by determining its sensitivity, accuracy and precision. The proposed method is simple, fast, accurate and precise and hence can be applied for routine quality control of nebivolol in bulk and tablet dosage form.


2008 ◽  
Vol 5 (s2) ◽  
pp. 1081-1086
Author(s):  
Palaniappan Mohanraj ◽  
Deb Kumar Sarkar ◽  
Tirthankar Choudhury ◽  
Karunakaran Gauthaman

A reverse phase HPLC method is described for the determination of nevirapine in tablet dosage forms. Chromatography was carried on an ODS column using a mixture of methanol and water (89:11 v/v) as the mobile phase at a flow rate of 1 mL/min with detection at 284 nm. The retention time of the drug was 3.22 min. The detector response was linear in the concentration of 25-200 mcg/mL. The limit of detection and limit of quantification was 0.004 and 0.0121 mcg/mL respectively. The percentage assay of nevirapine was 99.52%. The method was validated by determining its sensitivity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of nevirapine in bulk and tablet dosage forms.


Author(s):  
Devi Ramesh ◽  
Mohammad Habibuddin

Objective: The objective of the present study is to develop and validate a simple, rapid, sensitive reverse phase HPLC method for the determination of Armodafinil present in bulk and its pharmaceutical formulations.Methods: The chromatographic separation was achieved by using Hypersil ODS C-18 (150 x 4.6 mm, 5µ) in an isocratic mode with mobile phase methanol: phosphate buffer 3.0 (60:40 %v/v) was used. The flow rate was 1 ml/min and effluent was monitored at 225 nm. The method was validated for validation parameters i.e. linearity, accuracy, precision and robustness according to ICH guidelines.Results: The retention time of Armodafinil was 4.2 min and the linearity range of the method was 500-20000ng/ml with regression (r2) coefficient 0.9998. The method was validated for precision, accuracy, robustness and which were found to be within the acceptable limits according to the ICH guidelines. Also, the method was successfully applied for the estimation of Armodafinil in the marketed formulation of Nuvigil and the recovery was found to be>98%.Conclusion: The developed method possess good selectivity, specificity, there is no interference found in the blank at a retention time of ARM and good correlation between the peak area and concentration of the drugs under prescribed conditions. Hence, the method can be applied for routine analysis of Armodafinil. 


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (07) ◽  
pp. 54-57
Author(s):  
P. Sathyanarayana ◽  
◽  
M Vijayalakshmi ◽  
B. N. V Ravi Kumar

A RP-HPLC method was developed and validated for the determination of ramosetron hydrochloride in pharmaceutical formulation as per ICH and FDA guidelines. The method was carried out on a Phenomenex RP-C18 column using a mixture of methanol and water (95:5) in an isocratic mode. The flow rate is 0.8 mL/min and the detection was done at 302 nm. The linearity range was observed in the range of 1-6 mcg/mL. The accuracy of the method was found to be 99.0 to 99.5% and %RSD was found to be less than 2% indicating high degree of accuracy and precision for the proposed HPLC method. Limit of detection and limit of quantification of the method were found to be 0.028 and 0.0851 mcg/mL respectively.


2017 ◽  
Vol 9 (6) ◽  
pp. 54 ◽  
Author(s):  
Yuliya Kondratova ◽  
Liliya Logoyda ◽  
Yuliia Voloshko ◽  
Ahmed Abdel Megied ◽  
Dmytro Korobko ◽  
...  

Objective: A rapid, simple and sensitive RP-HPLC method was developed and validated for the determination of bisoprolol fumarate in bulk and pharmaceutical dosage form.Methods: Chromatographic separation was achieved within 2.5 min on ACQUITY Arc System, Waters Symmetry C18 column (3.9 mm i.d. X 150 mm, 5 μm particle sizes) using a mobile phase consisted of acetonitrile: phosphate buffer (25:75 v/v) in an isocratic mode at a flow rate of 1.4 ml/min. The pH of the mobile phase was adjusted to 7.0 with orthophosphoric acid and UV detection was set at 226 nm.Results: The retention time for bisoprolol fumarate was found to be 2.09 min. The proposed method was validated according to ICH guidelines with respect to linearity, specificity precision, accuracy and robustness. The limit of detection and limit of quantification are calculated and found to be 0.4825 and 1.4621 μg/ml; respectively.Conclusion: The proposed method can help research studies, quality control and routine analysis with lesser resources available. The results of the assay of pharmaceutical formulation of the developed method are highly reliable and reproducible and is in good agreement with the label claim of the medicines.Keywords: Bisoprolol, High-Performance Liquid Chromatography, Validation, ICH guidelines


2021 ◽  
Vol 32 (1) ◽  
pp. 70-75
Author(s):  
Simona Gherman ◽  
Daniela Zavastin ◽  
Adrian Şpac ◽  
Alina Diana Panainte

Abstract For the determination of enalapril maleate in tablets a new, simple and economical HPLC method was developed and fully validated. Chromatographic separation was achieved on Hewlett Zorbax SB-C 18 (150 x 4.6 mm, 5 μm) column and the mobile phase consisted of acetonitrile: 0.025 M phosphate buffer adjusted to pH 3 (70:30 v/v) pumped at a flow rate 0.8 mL/min and UV-detection was performed at 210 nm. The proposed method was validated according to ICH guidelines (linearity, limit of detection, limit of quantification, precision, accuracy, recovery and system suitability). The total run time was less than 3 min and the retention time for Enalapril maleate was 2.3 min. The calibration graph was linear in the concentration range between 10 – 100 μg/mL with the correlation coefficient r2 = 0.9998. The developed and validated method was successfully applied to determine the Enalapril maleate in tablets. Therefore, this method proved to be sensitive, specific and reproducible and can be applied for routine analysis of enalapril maleate from pharmaceutical formulation due to its simplicity of application.