DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF RAMOSETRON HYDROCHLORIDE IN BULK AND TABLETS

INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (07) ◽  
pp. 54-57
Author(s):  
P. Sathyanarayana ◽  
◽  
M Vijayalakshmi ◽  
B. N. V Ravi Kumar

A RP-HPLC method was developed and validated for the determination of ramosetron hydrochloride in pharmaceutical formulation as per ICH and FDA guidelines. The method was carried out on a Phenomenex RP-C18 column using a mixture of methanol and water (95:5) in an isocratic mode. The flow rate is 0.8 mL/min and the detection was done at 302 nm. The linearity range was observed in the range of 1-6 mcg/mL. The accuracy of the method was found to be 99.0 to 99.5% and %RSD was found to be less than 2% indicating high degree of accuracy and precision for the proposed HPLC method. Limit of detection and limit of quantification of the method were found to be 0.028 and 0.0851 mcg/mL respectively.

2010 ◽  
Vol 7 (3) ◽  
pp. 807-812 ◽  
Author(s):  
Vanita Somasekhar ◽  
D. Gowri Sankar

A reverse phase HPLC method is described for the determination of esmolol hydrochloride in bulk and injections. Chromatography was carried on a C18column using a mixture of acetonitrile, 0.05 M sodium acetate buffer and glacial acetic acid (35:65:3 v/v/v) as the mobile phase at a flow rate of 1 mL/min with detection at 275 nm. The retention time of the drug was 4.76 min. The detector response was linear in the concentration of 1-50 μg/mL. The limit of detection and limit of quantification was 0.614 and 1.86 μg/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of esmolol hydrochloride in bulk and injections.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (07) ◽  
pp. 49-53
Author(s):  
A Singla ◽  
◽  
Y. Paul ◽  
B. Singh

A simple, precise, accurate, reproducible and robust analytical method was developed using reversed phase HPLC for quantitative estimation of lercanidipine in biological matrices. The method was validated as per the ICH and FDA guidelines. Analysis of the drug was performed in an isocratic mode employing methanol and acetonitrile (74:26) as the mobile phase on a C18 column. UV-Visible detector at 219 nm was found to be suitable for drug estimation. Linearity was observed in the range of 5 and 500 ng/mL (p<0.001). Recovery was found to range between 96.26% and 100.67%. The % RSD values for method precision and system precision were found to be 0.437 and 1.58, respectively. Limit of detection (LOD) and limit of quantification (LOQ) were observed to be 0.20 ng/mL and 0.68 ng/mL, respectively.


2016 ◽  
Vol 10 (1) ◽  
pp. 33-43 ◽  
Author(s):  
Najmul Hasan ◽  
Mathurot Chaiharn ◽  
Umair Ali Toor ◽  
Zulfiqar Ali Mirani ◽  
Ghulam Sajjad ◽  
...  

In this article we describe development and validation of stability indicating, accurate, specific, precise and simple Ion-pairing RP-HPLC method for simultaneous determination of paracetamol and cetirizine HCl along with preservatives i.e. propylparaben, and methylparaben in pharmaceutical dosage forms of oral solution and in serum. Acetonitrile: Buffer: Sulfuric Acid (45:55:0.3 v/v/v) was the mobile phase at flow rate 1.0 mL min-1 using a Hibar® Lichrosorb® C18 column and monitored at wavelength of 230nm. The averages of absolute and relative recoveries were found to be 99.3%, 99.5%, 99.8% and 98.7% with correlation coefficient of 0.9977, 0.9998, 0.9984, and 0.9997 for cetirizine HCl, paracetamol, methylparaben and Propylparaben respectively. The limit of quantification and limit of detection were in range of 0.3 to 2.7 ng mL-1 and 0.1 to 0.8 ng mL-1 respectively. Under stress conditions of acidic, basic, oxidative, and thermal degradation, maximum degradation was observed in basic and oxidative stress where a significant impact was observed while all drugs were found almost stable in the other conditions. The developed method was validated in accordance with ICH and AOAC guidelines. The proposed method was successfully applied to quantify amount of paracetamol, cetirizine HCl and two most common microbial preservatives in bulk, dosage form and physiological fluid.


Author(s):  
SYED IBRAHIM BAJE ◽  
B. JYOTHI ◽  
N. MADHAVI

Objective: The objective of the present study was to develop and validate a novel reverse phase high performance liquid chromatographic (RP-HPLC) method, for simultaneous determination of ritonavir (RIT), ombitasvir (OMB) and paritaprevir (PAR) in bulk mixtures, and in tablets. Methods: Determination of the drugs ritonavir (RIT), ombitasvir (OMB), and paritaprevir (PAR), was carried out applying Hypersil BDS C18 column (250 mm X 4.6 mm i.e., 5 µm particle size), with photodiode array detector at λmax of 254 nm. The mobile phase applied for the current study composed of two solvents, i.e. A (0.01N % w/v potassium di-hydrogen orthophosphate buffer, pH 3.0 adjusted with dilute orthophosphoric acid) and B (acetonitrile). The mobile phase was pumped at a flow rate of 1.0 ml/min in the isocratic mode. The validation study with respect to specificity, linearity, precision, accuracy, and robustness, limit of detection (LOD) and limit of quantification (LOQ) was carried out employing the ICH guidelines. Results: Ritonavir, ombitasvir, and paritaprevir showed linearity of response between 12.5-75 μg/ml for ritonavir, 3.125-18.75 µg/ml for ombitasvir and 18.75–112.5 µg/ml for paritaprevir, with a correlation coefficient (R2) 0.999, 0.999,0.999 for RIT, OMB, and PAR respectively. The % recovery obtained was 99.82±0.14 % RIT, OMB 100.03±0.96 % and for 99.96±0.26 % PAR. The LOD and LOQ values for RIT, OMB, PAR were obtained to be 0.02, 0.019and0.02, µg/ml and 0.07, 0.06 and 0.07 µg/ml, respectively. The method also exhibits good robustness for different chromatographic conditions like wavelength, flow rate, mobile phase, and injection volume. Conclusion: The method was successfully employed, for the quantification of RIT, OMB, and PAR, in the quality control of in-house developed tablets, and can be applied for the industrial use.


2014 ◽  
Vol 50 (4) ◽  
pp. 793-797 ◽  
Author(s):  
Vanita Somasekhar

A reverse phase HPLC method is described for the determination of 6-mercaptopurine in bulk and tablets. Chromatography was carried on a C18 column using a mixture of acetonitrile and 0.05 mol/L sodium acetate buffer (10:90 v/v) as the mobile phase at a flow rate of 1 mL/min-1 with detection at 324 nm. The retention time of the drug was 3.25 min. The detector response was linear in the concentration of 0.01-5 μg/mL. The limit of detection and limit of quantification were 17 and 52 ng/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of mercaptopurine in bulk and tablets.


Author(s):  
Ankit Acharya ◽  
N.K. Satish ◽  
L. Manoj ◽  
Renukaradhya Chitti

The main objective of present study is to develop and validate a new, simple, precise and accurate RP-HPLC method for the determination of Darifenacin Hydrobromide (DFH) in bulk and pharmaceutical dosage forms. The separation and quantification of the drug was achieved on a RP C18 column (250×4.6mm, 5μm) using a mobile phase of acetonitrile: buffer (50:50), pH 3.0 ± 0.2 at a flow rate of 1 mL/min with detection of analyte at 287 nm. The separation was achieved with in 4.0 ± 0.3 min. The method showed good linearity in the range of 10-100 μg/mL. The intra and inter day RSD ranged from 0.20-0.58%. The recovery (mean ± SD) of low, medium and high concentrations were 98.50 ± 0.20, 100.27 ± 0.15 and 100.90 ± 0.09 respectively. The limit of detection and limit of quantification were 0.31 and 0.61 μg/mL, respectively. It can be concluded that the present method could be superior over the methods which were reported earlier. Kathmandu University Journal of Science, Engineering and TechnologyVol. 13, No. 1, 2017, Page: 36-44 


Separations ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. 5
Author(s):  
Mohd Afzal ◽  
Mohd. Muddassir ◽  
Abdullah Alarifi ◽  
Mohammed Tahir Ansari

A highly specific, accurate, and simple RP-HPLC technique was developed for the real-time quantification of domperidone (DOMP) and lansoprazole (LANS) in commercial formulations. Chromatographic studies were performed using a Luna C8(2), 5 μm, 100Å, column (250 × 4.6 mm, Phenomenex) with a mobile phase composed of acetonitrile/2 mM ammonium acetate (51:49 v/v), pH 6.7. The flow rate was 1 mL·min−1 with UV detection at 289 nm. Linearity was observed within the range of 4–36 µg·mL−1 for domperidone and 2–18 µg·mL−1 for lansoprazole. Method optimization was achieved using Box-Behnken design software, in which three key variables were examined, namely, the flow rate (A), the composition of the mobile phase (B), and the pH (C). The retention time (Y1 and Y3) and the peak area (Y2 and Y4) were taken as the response parameters. We observed that slight alterations in the mobile phase and the flow rate influenced the outcome, whereas the pH exerted no effect. Method validation featured various ICH parameters including linearity, limit of detection (LOD), accuracy, precision, ruggedness, robustness, stability, and system suitability. This method is potentially useful for the analysis of commercial formulations and laboratory preparations.


2020 ◽  
Vol 32 (9) ◽  
pp. 2208-2212
Author(s):  
CH. RAMESH ◽  
DHARMASOTH RAMA DEVI DEVI ◽  
M.N.B. SRINIVAS ◽  
S. RADHA KRISHNA ◽  
NAGARAJU RAJANA ◽  
...  

simple, specific, linear, accurate and precise reverse phase chiral HPLC method was developed for the separation of efavirenz enantiomers by using the Lux Amylose-2 column containing amylose tris(5-chloro-2-methyl phenyl carbamate) as a stationary phase. The mobile phase consists of 0.1 % formic acid in water and acetonitrile (55:45, v/v). The flow rate was kept at 1.0 mL/min and the detection wavelength used 252 nm and the column temperature was set at 25 ºC. The limit of detection was 0.01 mg/mL and the limit of quantification was 0.04 mg/mL. The linearity calibration curve of (R)-enantiomer was shown well from the range of 0.04 mg/mL to 0.4 mg/mL. The values of the correlation coefficient were 0.999 and 0.999 for (R)-enantiomer and (S)-efavirenz, respectively. The percentage recoveries of (R)-enantiomer from efavirenz drug substance were ranged from 93.5% to 107.5%. The results demonstrated that developed RP-chiral HPLC method was simple, precise, robust and applicable for the estimation of (R)-enantiomer in efavirenz API. This method was validated in as per ICH Q2 (R1) and USP validation of compendial methods <1225>.


2020 ◽  
Vol 10 (6) ◽  
pp. 49-56
Author(s):  
Sneha Jagnade ◽  
Pushpendra Soni ◽  
Lavakesh Kumar Omray

The aim of present study was to investigate the development and validation of a green analytical method for the determination of aspirin and domperidone. Method Development and Validation for Estimation of Domperidone and Aspirin in bulk or formulation by using RP-HPLC. The RP-HPLC method was developed for estimation of Aspirin and Domperidone in synthetic mixture by isocratically using 10 mM KH2PO4: Acetonitrile (20:80) as mobile phase, Prontosil C-18 column (4.6 x 250 mm, 5μparticle size) column as stationary phase and chromatogram was recorded at 231 nm. Then developed method was validated by using various parameters such as, linearity, Range accuracy, precision repeatability, intermediate precision, robustness, limit of detection, limit of quantification. The proposed methods were found to be linear with correlation coefficient close to one. Precision was determined by repeatability, Intermediate precision and reproducibility of the drugs. The robustness of developed method was checked by changing in the deliberate variation in solvent. The result obtained shows the developed methods to be Cost effective, Rapid (Short retention time), Simple, Accurate (the value of SD and % RSD less than 2), Precise and can be successfully employed in the routine analysis of these drugs in bulk drug as well as in tablet dosage form. The Simplicity, Rapidly and Reproducibility of the proposed method completely fulfill the objective of this research work. Keywords: Asprin; Domperidone; HPLC; Ultra Violet; Validation


Author(s):  
Zahid Zaheer ◽  
Sarfaraz Khan ◽  
Mohammad Sadeque ◽  
Hundekari G. I. ◽  
Rana Zainuddin

A simple, reproducible and efficient reverse phase high performance liquid chromatographic method was developed for Lisinopril in bulk drug and formulation. A column having 150 × 4.6 mm in isocratic mode with mobile phase containing acetonitrile: phosphate buffer (70:30; adjusted to pH 3.0) was used. The flow rate was 0.8 ml/min and effluent was monitored at 216 nm. The retention time (min) and linearity range (μg/ml) for Lisinopril was (1.510) and (10-35). The developed method was found to be accurate, precise and selective for determination of Lisinopril in bulk and formulation.


Sign in / Sign up

Export Citation Format

Share Document