scholarly journals A Novel Signal-Amplified Immunoassay for the Detection of C-Reactive Protein Using HRP-Doped Magnetic Nanoparticles as Labels with the Electrochemical Quartz Crystal Microbalance as a Detector

2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Ning Gan ◽  
Ping Xiong ◽  
Ji Wang ◽  
Tianhua Li ◽  
Futao Hu ◽  
...  

A novel horseradish peroxidase- (HPR-) doped magnetic core-shell Fe3O4@SiO2@Au nanocomposites (Fe-Au MNPs) were employed on immunoassay for the determination of C-reactive protein (CRP) based on a electrochemical quartz crystal microbalance detector (EQCM). Firstly, the secondary CRP antibody and HRP were both immobilized on the Fe-Au MNPs (Fe-Au MNPs-anti-CRP2/HRP) as a signal tag. Secondly, the above tag and the primary antibody (anti-CRP1) in the bottom of 96-well microtiter plate were employed to conjugate with a serial of CRP concentrations to produce a sandwich immunocomplex. Thirdly, the immunocomplex solution was subsequently exposed to3,3′-diaminobenzidine (DAB) in the presence of H2O2, resulting in an insoluble product. When the precipitation solution was dripped on EQCM, it can achieve a decrease of frequency of crystal (Δf). The amount ofΔfwas proportional to (CRP) from 0.003 to 200 ng mL−1with a low detection limit of 1 pg mL−1. Compared with the enzyme-linked immunosorbent assay (ELISA), the immunoassay shows greatly improved sensitivity due to the significant amount of HRP labeled on signal tag. It also has good specificity and low sample consumption, which is expected to be a benefit for the CRP screening in early diagnosis of cardiovascular disease.

1997 ◽  
Vol 502 ◽  
Author(s):  
James J. Kelly ◽  
Christopher J. Durning ◽  
Alan C. West

ABSTRACTSpatially nonuniform electrodeposition can cause discrepancies between predicted and experimentally measured mass loadings on an electrochemical quartz crystal microbalance (EQCM) since the sensitivity of the quartz crystal varies significantly from point to point. These discrepancies can be significant even if the current distribution is nearly uniform. These effects were examined experimentally by varying the conductivity of the electrolyte and the current density during the electrodeposition of copper on an EQCM, effecting changes in the spatial, deposited-mass distribution in a controlled manner. The resulting frequency shifts are in agreement with results predicted by current distribution simulations, validated a posteriori with profilometry measurements. Our results permit determination of the spatial variation of the quartz crystal sensitivity factor or of the current distribution on the EQCM.


2004 ◽  
Vol 16 (21) ◽  
pp. 1814-1822 ◽  
Author(s):  
A. Doménech-Carbó ◽  
S. Sánchez-Ramos ◽  
D. J. Yusá-Marco ◽  
M. Moya-Moreno ◽  
J. V. Gimeno-Adelantado ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document