scholarly journals Effect of Bleaching and Thermocycling on Resin-Enamel Bond Strength

2015 ◽  
Vol 2015 ◽  
pp. 1-6
Author(s):  
Horieh Moosavi ◽  
Hamideh Sadat Mohammadipour ◽  
Marjaneh Ghavamnasiri ◽  
Sanaz Alizadeh

The aim of this study was to evaluate the effect of bleaching and thermocycling on microshear bond strength of bonded resin composites to enamel. Enamel slices were prepared from ninety-six intact human premolars and resin composite cylinders were bonded by using Adper Single Bond 2 + Filtek Z350 or Filtek silorane adhesive and resin composite. Each essential group was randomly subdivided to two subgroups: control and bleaching. In bleaching group, 35% hydrogen peroxide was applied on samples. Thermocycling procedure was conducted between 5°C and 55°C, for 3.000 cycles on the half of each subgroup specimen. Then microshear bond strength was tested. Methacrylate-based resin composite had higher bond strength than silorane-based one. The meyhacrylate-based group without bleaching along with thermocycling showed the most bond strength, while bleaching with 35% carbamide peroxide on silorane-based group without thermocycling showed the least microshear bond strength. Bleaching caused a significant degradation on shear bond strength of silorane-based resin composites that bonded using self-etch adhesive resin systems.

Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


2021 ◽  
Vol 24 (2) ◽  
Author(s):  
Fateme Vasei ◽  
Farahnaz Sharafeddin

Objective: To assess the shear bond strength (SBS) of resin composite to deep dentin, using 1 and 2.5% chitosan pretreatment as well as different adhesive systems. Material and Methods: 80 human maxillary molars were randomly divided to eight groups according to the type of adhesive system and dentin pretreatment (n = 10): I) two-step self-etch system (Clearfil SE bond); II) two-step etch-andrinse system (Adper single bond 2); III) 2.5% chitosan + Clearfil SE bond; IV) 2.5% chitosan +etch + Adper single bond 2; V) etch + 2.5% chitosan + Adper single bond 2; VI) 1% chitosan + Clearfil SE bond; VII) 1% chitosan + etch + Adper single bond 2; VIII) etch + 1% chitosan + Adper single bond 2 (chitosan solution (w/v): 2.5 g and 1 g of chitosan (Sigma Aldrich, USA) was dissolved in 100 ml of 1% acetic acid). Plastic molds were positioned on dentin and filled with composite (Z350, 3M ESPE, USA). SBS (MPa) was tested using a universal testing machine. ANOVA tests, Tukey’s test, and independent t test were used to analyze data (p < 0.05). Results: The highest SBS value among self-etch groups was observed with 1% chitosan (p = 0.001). In the etch-and-rinse group, the SBS of 1% chitosan was significantly lower than the other groups. Chitosan treatment following acid etching led to higher SBS in comparison to when chitosan was applied before etching, with the significant difference in 1% concentration (p = 0.030). A predominance of mix fractures was observed in dentin. Conclusion: Improved dentin bond strength can be achieved through immediate dentin pretreatment with 1% chitosan in self-etch adhesive systems. Chitosan Pretreatment may not be advantageous for etch-and-rinse adhesive systems. Keywords Adhesive system; Chitosan; Deep dentin; Shear strength.


2020 ◽  
Vol 8 (10) ◽  
pp. 454-459
Author(s):  
Bhalla V. ◽  
◽  
K. Goud M. ◽  
Chockattu S. ◽  
Khera A ◽  
...  

Background:Dentin bonding is an ever-evolving field in adhesive dentistry. With the introduction of newer systems into the market, there is a crucial need to test their efficiency in terms of bond strength. Dual-cured adhesives in theory may provide for a better degree of conversion as compared to conventional light-cured adhesives .Thus, the aim of this study was to compare the shear bond strength of three different self-etch adhesives namely ClearfilSE bond (Kuraray), Tetric N Bond Universal (IvoclarVivadent) and Futura Bond DC (Voco) to dentin. Materials & Methods: Ninety extracted non-carious, intact human mandibular molar teeth were selected for this study. Each tooth was decoronated using a double-sided diamond disc with water coolant to a depth of 2mm from the cusp tip .The cut dentin surface was then abraded against 600-grit wet silicon carbide papers for 60 seconds to produce a uniform smear layer. The root portion of each tooth was mounted on a plastic ring using cold cure acrylic resin. Specimens were then divided into three adhesive groups of 30 teeth each, Group A: ClearfilSE Bond (Kuraray), Group B: Tetric N Bond Universal (IvoclarVivadent), Group C :Futura Bond DC (Voco). All bonding agents were used according to the manufacturers’ instructions, in combination with the resin composite Tetric N Ceram (IvoclarVivadent). The samples were thermocycled, followed by shear bond strength testing using a Universal testing machine (Hounsfield). Data were subjected to statistical analysis using one-way analysis of variance (ANOVA) (P<0.05) and Post hoc Tukey’s test for inter- and intra- group analysis respectively. Results: Clearfil SE Bond yielded the highest shear bond strength values (30.9 ±4.66 MPa) which were statistically significant, followed byTetric N Bond Universal group (29.8 ±4.34) and the lowest shear bond strength values were recorded for Futura Bond DC (18.2 ±3.13). Conclusion: Clearfil SE bond and Tetric N bond Universal can be considered as better options than Futura Bond DC.


2015 ◽  
Vol 40 (1) ◽  
pp. 55-62 ◽  
Author(s):  
J-H Kim ◽  
S-Y Chae ◽  
Y Lee ◽  
G-J Han ◽  
B-H Cho

SUMMARY This study evaluated the effects of single-bottle, multipurpose, universal adhesives on the bond strength of resin cement to zirconia ceramic. Polished zirconia ceramic (Cercon base) discs were randomly divided into four groups (n=40) according to the applied surface-conditioning agent: Single Bond 2, Single Bond Universal, All-Bond Universal, and Alloy Primer. Cured composite cylinders (Ø 0.8 mm × 1 mm) were cemented to the conditioned zirconia specimens with resin cement (RelyX ARC). The bonded specimens were subjected to a microshear bond-strength test after 24 hours of water storage and after 10,000 cycles of thermocycling. The surface-conditioning agent significantly influenced the bond strength (p&lt;0.05). Single Bond Universal showed the highest initial bond strength (37.7 ± 5.1 MPa), followed by All-Bond Universal (31.3 ± 5.6 MPa), Alloy Primer (26.9 ± 5.1 MPa), and Single Bond 2 (8.5 ± 4.6 MPa). Artificial aging significantly reduced the bond strengths of all the test groups (p&lt;0.05). After 10,000 cycles of thermocycling, All-Bond Universal showed the highest bond-strength value (26.9 ± 6.4 MPa). Regardless of artificial aging, Single Bond Universal and All-Bond Universal showed significantly higher bond strengths than Alloy Primer, a conventional metal primer.


2015 ◽  
Vol 21 (6) ◽  
pp. 1523-1529 ◽  
Author(s):  
Patricia Makishi ◽  
Rafael R. Pacheco ◽  
Alireza Sadr ◽  
Yasushi Shimada ◽  
Yasunori Sumi ◽  
...  

AbstractShear bond strength (SBS) and the interfacial adaptation (IA) of self-adhesive resin (SAR) composites to dentin were evaluated. Two SARs [Vertise Flow (VTF) and Fusio Liquid Dentin (FLD)] were evaluated and compared with a conventional restorative system [adhesive: OptiBond FL and composite: Herculite Précis (OBF/HP)]. Human third molars were used for SBS testing and IA imaging (n=7) using optical coherence tomography (OCT). Flattened dentin disks were prepared and the composites were applied into molds (2.4 mm diameter) that were positioned on dentin. Samples were subjected to SBS testing and OCT analysis, which considered an increase in signal intensity at the bonded interface as evidence of internal gaps. SBS data were analyzed by one-way analysis of variance and Tukey’s test and IA data (% distribution of high brightness values) by Kruskal–Wallis and Dunn’s test (p≤0.05). No statistically significant difference in SBS was observed between VTF (13.9±3.6 MPa) and FLD (11.3±3.2 MPa), whereas OBF/HP showed higher average strength (27.3±6.1 MPa). However, there was a statistically significant difference in IA when VTF (33.3%) was compared with FLD (1.2%) and OBF/HP (1.5%). The conventional restorative system exhibited superior SBS performance compared with SARs. However, the IA of FLD to dentin had values that were not significantly different from OBF/HP.


2014 ◽  
Vol 13 (1) ◽  
pp. 7
Author(s):  
Dewi Puspitasari ◽  
Andi Soufyan ◽  
Ellyza Herda

Composite resin is a widely used aesthetic restoration. The restoration can fail due to secondary caries. Chlorhexidinegluconate 2% is used as a cavity disinfectant to eliminate microorganisms on the prepared cavity and to prevent thesecondary caries. The purpose of this study was to analyze the effect of chlorhexidine gluconate 2% to the bondstrength of composite resin with self etch system adhesive on dentine. Sixteen specimens of buccal dentine of premolarscrown are divided into 2 different groups. Group I: Clearfil SE Bond self-etch primer was applied for 20 seconds,Clearfil SE Bond bonding was applied for 5 seconds and polymerized for 10 seconds. Composite resin was constructedincrementally and polymerized for 20 seconds. Group II: prior to self etch primer application as in group I,chlorhexidine gluconate 2% was applied for 15 seconds. Shear bond strength was tested using Testing machine andanalyzed with unpaired T test. The highest shear bond strength was obtained by applying chlorhexidine gluconate 2%.The study concludes that chlorhexidine gluconate 2% application to dentine did not affect significantly to the bondstrength composite resin using self etch adhesive systems.


2020 ◽  
Author(s):  
Sana Lala ◽  
Thuraya Lazkani

Abstract Background:In restorative dentistry we usually use Sandwich Technique for posterior restorations where GIC is placed below and a resin composite is placed over it. The bonding strength between these two materials are low. We are looking for the best adhesive system to put it in between. We think that the self-etching bond will give the best bonding strength between them whereas total etch will give lower bonding strength than self-etching system. Methods:ION-Z GIC was bonded to resin composite by using two different bonding agents. The thirty specimens used were prepared by using acrylic blocks with holes in each hole to retain the ION-Z GIC. The specimens were randomly divided into three groups:Group I: Control group.Group II: Total-etch adhesive was applied and cured over ION-Z GIC.Group III: Self-etch adhesive was applied and cured.The composite resin placed over the ION-Z GIC and cured. The shear bond strength was measured by shearing of the bonded specimens on Universal Testing Machine (Model 114) using speed of 0.1mm / minute. The reading was tabulated and subjected to statistical analysis using ANOVA and Tukey's test.Results:The test showed statistically significant difference between Group III and Group I and between Group III and Group II. Group III had the highest shear bonding strength.Conclusion:Self-etch adhesive agent produces have better shear bond strength to ION-Z than total-etch adhesive and to the group without any bonding agent.


2021 ◽  
Vol 15 (1) ◽  
pp. 176-183
Author(s):  
Juthatip Aksornmuang ◽  
Juckrapun Tiangtrong

Aims: To compare the shear bond strength between resin composite and Poly(methyl methacrylate) (PMMA) with various bonding protocols and to evaluate the optical properties of resin composite - layered provisional Poly(methyl methacrylate) (PMMA). Materials and Methods: Eighty cylindrical shape specimens were fabricated from self-polymerized provisional Poly(methyl methacrylate) (PMMA) and they were randomly divided into eight groups. Poly(methyl methacrylate) (PMMA) was mixed and bonded onto the specimens as a positive control group. Resin composite was bonded to MMA-wetted surface without bonding agent as a negative control group. All remaining groups were bonded to resin composite using different bonding agents (Scothbond Universal, Luxatemp glaze&bond, and HC Primer) with and without MMA wetting. Shear bond strength testing was performed using a universal testing machine. Various shades of 0.5 mm-thick resin composites were layered onto 1.5 mm-thick PMMA both light and dark shade, with the most effective bonding protocol. Color differences between resin composite and – layered provisional Poly(methyl methacrylate) (PMMA) were measured using Spectrophotometer. Results: Bonding resin composite onto Poly(methyl methacrylate) (PMMA) using luxatemp glaze, bond and HC Primer without methyl methacrylate wetting provided statistically significantly lower bond strength than those of the MMA-wetted Poly(methyl methacrylate) (PMMA) surface. The highest shear bond strength was achieved with the application of Scothbond Universal Adhesive regardless of MMA wetting. The colors of resin composite - layered provisional Poly(methyl methacrylate) (PMMA) were different from the original resin composite color with ΔE results greater than the acceptable threshold (>3.7). Conclusion: Resin composites were able to effectively bond to the MMA-wetted Poly(methyl methacrylate) (PMMA) surface with the application of a tested bonding agent. Layering Poly(methyl methacrylate) (PMMA) with 0.5 mm-thick resin composite could not modify the Poly(methyl methacrylate) (PMMA) shade to the original resin composite color.