scholarly journals Two-Year Follow-Up after Contact Force Sensing Radiofrequency Catheter and Second-Generation Cryoballoon Ablation for Paroxysmal Atrial Fibrillation: A Comparative Single Centre Study

2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Attila Kardos ◽  
Zsuzsanna Kis ◽  
Zoltan Som ◽  
Zsofia Nagy ◽  
Csaba Foldesi

Background. There are little comparative data on catheter ablation of paroxysmal atrial fibrillation (AF) using the contact force radiofrequency (CF-RF) catheter versus the second-generation cryoballoon (CB2).Methods and results. This is a single center, retrospective, nonrandomized study of 98 patients with symptomatic, drug-refractory paroxysmal AF who underwent their first PVI ablation using either the CB2 (n=40) or CF-RF (n=58). The mean age was 60 years with 63% men, a mean LA size of 42 mm. The procedure duration (74±17versus120±49minutesp<0.05) was shorter for CB2 group; the fluoroscopy time (14±17versus16±5minutes,p=0.45) was similar. Complete PVI was achieved in 96% of patients with RF-CF and 98% with CB2. Phrenic nerve palsies (2 transient and 1 persistent) occurred exclusively in the CB2 group and 1 severe, nonlethal complication (pericardial tamponade) occurred in the CF-RF group. At 24-month follow-up, the success rate, defined as freedom from AF/atrial tachycardia (AT) after a single procedure without antiarrhythmic drug, was comparable in CF-RF group and CB2 group (65.5% versus 67%, resp., log rankp=0.54).Conclusion. Both the CB2 and the RF-CF ablation appeared safe; the success rate at 2 years was comparable between both technologies.

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
K Ukita ◽  
A Kawamura ◽  
H Nakamura ◽  
K Yasumoto ◽  
M Tsuda ◽  
...  

Abstract Background Little has been reported on the outcome of contact force (CF)-guided radiofrequency catheter ablation (RFCA) and second generation cryoballoon ablation (CBA). Purpose The purpose of this study was to compare the outcome of CF-guided RFCA and second generation CBA for paroxysmal atrial fibrillation (PAF). Methods We enrolled the consecutive 364 patients with PAF who underwent initial ablation between September 2014 and July 2018 in our hospital. We compared the late recurrence of atrial tachyarrhythmia more than three months after ablation between RFCA group and CBA group. All RFCA procedures were performed using CF-sensing catheter and all CBA procedures were performed using second generation CB. Results There were significant differences in background characteristics: chronic kidney disease, serum brain natriuretic peptide level, and left ventricular ejection fraction. After propensity score matched analysis (Table), atrial tachyarrhythmia free survival was significantly higher in CBA group than in RFCA group (Figure). Conclusions Second generation CBA showed a significantly lower late recurrence rate compared to CF-guided RFCA. Kaplan-Meier Curve Funding Acknowledgement Type of funding source: None


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
R Rordorf ◽  
S Cornara ◽  
L Frigerio ◽  
A Sanzo ◽  
E Chieffo ◽  
...  

Abstract Background Pulmonary veins isolation (PVI)is an effective therapy for atrial fibrillation (AF), recommended by current guidelines. However, recurrences after first radio-frequency (RF) catheter ablation (CA) are still high. PV reconnection could be due to ineffective transmural lesions; automated ablation lesion tags (the VisiTag algorithm) based on predefined parameters of catheter stability and contact force (CF) have been developed to allow the detection of ineffective ablation lesion, nevertheless there is a lack of multicenter studies exploring this technology. Objective the aim of our study was to assess the rate of recurrence after a first PVI procedure in a large, multicentric Italian population and to explore the efficacy of Visitag algorithm (CARTO 3) used to guide RF ablation of AF. Methods we analyzed 214 patients of the SMOP-AF study (Substrate Mapping as Outcome Predictor in Atrial Fibrillation Ablation), a prospective multi-centric study enrolling patients with paroxysmal and persistent AF undergoing a first PVI procedure after an high-density mapping during sinus rhythm. During the procedure, ablation was guided by an automated annotation system in which tag based on predefined parameters were displayed real-time in each lesion site on the electroanatomical map. Visitag settings for the catheter position stability were a 2,5 mm distance limit for at least 7 sec and a minimum CF of 5 g over 30% of the ablation and a FTI>400 g*s. Where available (n=106, 49.5%), Ablation Index (AI), which also incorporates information on delivered RF power, was used instead of FTI to guide RF ablation with a threshold range of 400–550 for anterior/roof and 330–420 for posterior/inferior segments. Minimum and mean contact force, time and power values for each RF-lesion were recorded while both FTI and AI values were calculated automatically by the CARTO system. Comparison between groups were made by cross-tables, Mann-Whitney or Student T test as appropriated. Results the mean age of the enrolled population was 59±9 years, left ventricular ejection fraction was 59±9%. AF was paroxysmal in 89.7%, persistent in 10.3% of the patients and refractory to at least one anti-arrhythmic drug in 86.4% of the population. At 3 months follow-up 85% of the patients were free from AF recurrences and the success rate increased to 90.8% at 3–6 months, and 86.3% at 3–12 months follow-up. The mean ablation time was shorter in AI-guided vs. FTI-guided procedures (31±9 vs 46±29 min; p<0.001). There was a trend toward a reduction in AF recurrences when AI vs. FTI was used, both at 6 and 12 months (respectively 5,4% vs 13.6%; p 0.06 and 9.6% vs 18.5%; p 0.08). Conclusion PVI isolation using dedicated algorithms developed to guide the effectiveness of RFCA leads to a very high success-rate after a single procedure. The use of AI, which integrates contact force information with delivered power, reduces the procedural time and increases the overall success-rate


EP Europace ◽  
2014 ◽  
Vol 16 (5) ◽  
pp. 639-644 ◽  
Author(s):  
G.-B. Chierchia ◽  
G. Di Giovanni ◽  
G. Ciconte ◽  
C. de Asmundis ◽  
G. Conte ◽  
...  

QJM ◽  
2020 ◽  
Vol 113 (Supplement_1) ◽  
Author(s):  
O H M A Riad ◽  
T Wong ◽  
A N Ali ◽  
M T Ibrahim ◽  
M A Abdelhamid ◽  
...  

Abstract Background Pulmonary vein isolation (PVI) has become the mainstay of catheter ablation of atrial fibrillation (AF). There are two commonly used methods to isolate the pulmonary veins, either point-by-point delivery of circumferential lesion sets around ipsilateral pulmonary veins using radiofrequency energy, or the application of the cryoballoon to the pulmonary vein antrum with occlusion of the vein ostium. The cryoballoon has proven to be a reliable alternative to radiofrequency ablation in acute and long-term freedom from AF. We describe our results using both modalities. Aim and Objectives to compare the safety and efficacy of cryoballoon (CB) ablation and radiofrequency (RF) ablation in treatment of paroxysmal atrial fibrillation. Patients and Methods Forty-four consecutive patients having paroxysmal AF underwent PVI using the second generation cryoballoon were compared to a retrospective cohort of 69 patients who had radiofrequency induced PVI, either by conventional RF catheter (n = 32), or a contact-force sensing-catheter (n = 37). The study took place at Ain Shams university hospitals and Royal Brompton & Harefield NHS trust. Patient data, procedural data and follow up data- at 3, 6 and 12 months- were collected and analysed. Recurrence was defined as documented AF or atrial arrhythmias with duration exceeding 30 seconds, either by 12 lead ECG or an ambulatory monitoring device. Results A total of 113 patients were studied. The mean age was 53.84 ± 15.01 for the CB group and 55.78 ± 14.84 for the RF group and females representing 40.9% vs 34.8% respectively. The mean procedural times in minutes were significantly less in the CB group (94.37 ± 39.32 vs 184.57 ± 88.19, p &lt; 0.0001), while the median fluoroscopy times were similar [30 (11.04 - 40) vs 37.25 (14.2 - 70), p = 0.172]. Procedural complications were comparable between the two groups (p = 0.06) with 1 patient (2.3%) having long term phrenic nerve paresis. At 1 year follow up, after an initial 90-day blanking period, recurrence rate of CB was similar to RF (27.3% vs 30.4% respectively, p = 0.719), the Kaplan Meier estimates of AF- free survival for a period of 1 year were comparable between both groups (log rank test, p = 0.606). Conclusion Cryoballoon is a feasible method for pulmonary vein isolation with similar success rates to radiofrequency ablation. Cryoballoon ablation is safe with shorter duration of the procedure.


2017 ◽  
Vol 49 (1) ◽  
pp. 93-100 ◽  
Author(s):  
Ken Takarada ◽  
Ingrid Overeinder ◽  
Carlo de Asmundis ◽  
Erwin Stroker ◽  
Giacomo Mugnai ◽  
...  

2016 ◽  
Vol 27 (6) ◽  
pp. 677-682 ◽  
Author(s):  
VALENTINA DE REGIBUS ◽  
GIACOMO MUGNAI ◽  
DARRAGH MORAN ◽  
BURAK HÜNÜK ◽  
ERWIN STRÖKER ◽  
...  

Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Xue Zhao ◽  
Jianqiang Hu ◽  
Yan Huang ◽  
Yawei Xu ◽  
Yanzhou Zhang ◽  
...  

Objectives: The aim of this study was to determine the mechanisms and effectiveness of pulmonary antrum radial-linear (PAR) ablation in comparison with pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF) after a long-term follow-up. Background: The one-year follow up data suggested that PAR ablation appeared to have a better outcome over the conventional PVI for paroxysmal AF. Methods: The enrollment occurred between March, 2011, and August, 2011, with the last follow-up in May, 2014. A total of 133 patients with documented paroxysmal AF were enrolled from 5 centers and randomized to PAR group or PVI group. Event ECG recorder and Holter monitoring were conductedduring the follow-up for all patients. Results: The average procedure time was 151±23 min in PAR group and 178±43 min in PVI group ( P <0.001). The average fluoroscopy time was 21±7 min in PAR group and 27±11 min in PVI group ( P= 0.002). AF triggering foci were eliminated in 59 patients (89.4%) in PAR group, whereas, only 4 patients (6.0%) in PVI group (P<0.001).At median 36 (37-35) months of follow-up after single ablation procedure, 43 of 66 patients in PAR group (65%) and 28 of 67 patients in PVI group (42%) had no recurrence of AF off antiarrhythmic drug (AAD) (P=0.007); and 47 of 66 patients in PAR group (71%) and 32 of 67 patients in PVI group (48%) had no recurrence of AF with AAD (P=0.006). At the last follow-up, the burden of AF was significantly lower in PAR group than in PVI group (0.9% ± 2.3% vs 4.9% ± 9.9%;90th percentile, 5.5% vs 19.6%; P=0.008). No major adverse event (death, stroke, PV stenosis) was observed in all the patients except one case of pericardial tamponade. Conclusions: PAR ablation is a simple, safe, and effective strategy for the treatment of paroxysmal AF with better long-term outcome than PVI. PAR ablation might exhibit the beneficial effect on AF management through multiple mechanisms. Registration: ChiCTR-TRC-11001191