scholarly journals Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography

2017 ◽  
Vol 2017 ◽  
pp. 1-13 ◽  
Author(s):  
Lele Cui ◽  
Ming Li ◽  
Meixiao Shen ◽  
Fan Lu ◽  
Jianhua Wang

Objectives. To evaluate the centration and movement of soft contact lenses and to verify the repeatability of two repeated measurements of the lens centration and movement using ultra-long scan depth optical coherence tomography (UL-OCT). Methods. A 1-day Acuvue® Define™ lens was tested on both eyes of 10 subjects (5 males and 5 females; mean age, 31.6 years). The centration and blink-induced movement of the contact lens were measured using UL-OCT at 5 min and 30 min after insertion. The measurements were repeated once at each checkpoint. Results. Good repeatability was found in the lens centration and movement between the two repeated measurements at either checkpoint. The values of the lens movement were 0.457 ± 0.248 mm and 0.402 ± 0.229 mm at 5 min and decreased to 0.197 ± 0.065 mm and 0.211 ± 0.110 mm at 30 min after insertion for the right and left eyes, respectively (P<0.05). Conclusions. The custom-built UL-OCT presented good repeatability of centration and movement in Define lenses at 5 min and 30 min after insertion. Most of the lenses were centered temporal and inferior to the cornea during the first 30 min wearing period. Compared with 5 min after insertion, the lens was centered better and exhibited less movement at 30 min.

2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Lele Cui ◽  
Sisi Chen ◽  
Weihe Zhou ◽  
Kaixuan Sheng ◽  
Lei Zhang ◽  
...  

Purpose. To determine conjunctival overlap over the edge of soft contact lens and to visualize the peripheral postlens tear film (PoLTF) underneath soft contact lenses using ultrahigh-resolution optical coherence tomography (UHR-OCT). Methods. Twenty participants (4 males and 16 females, 23.0 ± 3.7 years) were fitted with two different types of soft contact lenses randomly. The limbus with lens was imaged with the UHR-OCT at the horizontal meridian every two hours up to 6 hours during lens wear. The conjunctival overlap was ranked as the percentage of the edge covered by the conjunctiva. The frequency of occurrence for visualized peripheral PoLTF was determined. Results. The average conjunctival overlaps at insertion were 49% and 73% for galyfilcon A and balafilcon A lenses and increased significantly to 84% and 90% by 6 hours of lens wear (P<0.001). Lenses with rounded edges had more conjunctival overlap than the lenses with angled edges (P=0.014). There were significant decreases for PoLTF on the conjunctiva (P=0.014) and peripheral cornea (P=0.004) over the study period compared to insertion. The percentage of subjects with PoLTF on the conjunctiva (32.5%) and peripheral cornea (36%) were greater in subjects wearing balafilcon A lenses (P=0.017). Conclusions. Increased conjunctival overlap over the lens edges and reduced PoLTF underneath the peripheral region of soft contact lenses were shown during lens daily wear. The lens edge configuration may play a role in conjunctival response and peripheral PoLTF.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Andrew Kwok-cheung Lam ◽  
Kenny Kin-hei Lau ◽  
Ho-yin Wong ◽  
Jasmine Pui-kwan Lam ◽  
Man-for Yeung

AbstractTo compare fixation deviation and stability with soft contact lens correction and device built-in auto-focus system during optical coherence tomography angiography (OCTA). This observational study measured OCTA metrics first with contact lens correction, followed by removal of contact lenses, using the device auto-focus system at a University Optometry Clinic, Hong Kong. All participants were habitual soft contact lens wearers with either low or high myopia. OCTA measurements were obtained using a spectral domain OCTA. Fixation deviation was distance (in pixels) of the fovea to the center of the OCTA measurement grid. Fixation stability was test–retest repeatability (TRR) and coefficient of variation (CV) of fixation deviation from three consecutive OCTA measurements. OCTA metrics included vessel length density (VD), perfusion density (PD), and foveal avascular zone (FAZ) area. Averaged OCTA metrics were calculated from three measurements and compared between the two correction methods. The mean ± SD spherical equivalent of 74 eyes from 74 myopes measured was − 1.94D ± 0.75D in low myopes (n = 37) and − 7.97D ± 1.31D in high myopes (n = 37). When corrected with contact lenses, visual acuities of high myopes (median [IQR], − 0.06 [0.08] logMAR) and low myopes (− 0.02 ± 0.08 logMAR) were similar (P = 0.060), and with similar fixation deviation (5.0 ± 2.2 pixels vs 5.3 [3.6] pixels; P = 0.689). High myopes had poorer fixation stability than low myopes (TRR: 10.2 pixels vs 7.5 pixels; CV: 65% vs 54%, respectively). The worst fixation stability occurred when high myopes were corrected using the auto-focus system (TRR: 12.5 pixels, CV: 72%). The difference in VD and PD was within 1 mm−1 and 1%, respectively. The FAZ area was similar. Difference in OCTA metrics was small in each refractive group (< 1 mm−1 in VD, and < 2% in PD). High myopes had more stable fixation when corrected when wearing contact lenses. Subjects with good contact lens corrected visual acuity should wear their contact lenses during OCTA measurements.


2021 ◽  
Vol 15 (6) ◽  
pp. 1562-1564
Author(s):  
Didik Wahyudi ◽  
J Dahjono ◽  
Untung Suparman

Background: Refractive errors have occurred in many parts of the world, including in Indonesia, with different types of abnormalities, one of which is myopia which can be corrected with glasses and spherical contact lenses. Aim: To determine the relationship between the level of knowledge of the installation and care of soft contact lenses in myopic patients. Methods: This research method is Cross Sectional at Optik Metro, the number of samples is the total population, the research instrument is a questionnaire, the independent variable of this research is the level of knowledge while the dependent variable is the attitude and behavior of Care and Installation with Successful Use of Contact Lenses. This research has been approved by the Widya Husada STIKES Ethics Commission. Results: The results of the study based on the number of sufferers and the distribution of refractive errors at Optik Metro from March 15-20, 2021, showed that the number of myopia patients who came was 13.0% with the type of treatment using soft contact lenses as much as 2.2%. There is a relationship between knowledge and attitudes of respondents with maintenance and installation behavior with successful use of LK with a significance value of 0.000 (p < 0.05). Conclusion: It was concluded that the toric soft contact lens installation procedure was carried out in the right way by taking into account a good fitting assessment. It is necessary to provide education to increase knowledge and education on Care and Installation of Contact Lenses for all customers. Keywords: Knowledge, Attitude, Soft LK, Myopia


2021 ◽  
Author(s):  
Andrew Kwok-cheung Lam ◽  
Kenny Kin-hei Lau ◽  
Ho-yin Wong ◽  
Jasmine Pui-kwan Lam ◽  
Man-for Yeung

Abstract ObjectiveTo compare fixation deviation and stability with soft contact lens correction and device built-in auto-focus system during optical coherence tomography angiography (OCTA).MethodsThis observational study measured OCTA metrics first with contact lens correction, followed by removal of contact lenses, using the device auto-focus system at a University Optometry Clinic, Hong Kong. All participants were habitual soft contact lens wearers with either low or high myopia. OCTA measurements were obtained using a spectral domain OCTA. Fixation deviation was distance (in pixels) of the fovea to the center of the OCTA measurement grid. Fixation stability was test-retest repeatability (TRR) and coefficient of variation (CV) of fixation deviation from three consecutive OCTA measurements. OCTA metrics included vessel length density (VD), perfusion density (PD), and foveal avascular zone (FAZ) area. Averaged OCTA metrics were calculated from three measurements and compared between the two correction methods.ResultsThe mean ± SD spherical equivalent of 74 eyes from 74 myopes measured was -1.94D ± 0.75D in low myopes (n=37) and -7.97D ± 1.31D in high myopes (n=37). When corrected with contact lenses, visual acuities of high myopes (median [IQR], -0.06 [0.08] logMAR) and low myopes (0.02 ± 0.08 logMAR) were similar (P = 0.060), and with similar fixation deviation (5.0 ± 2.2 pixels vs 5.3 [3.6] pixels; P = 0.689). High myopes had poorer fixation stability than low myopes (TRR: 10.2 pixels vs 7.5 pixels; CV: 65% vs 54%, respectively). The worst fixation stability occurred when high myopes were corrected using the auto-focus system (TRR: 12.5 pixels, CV: 72%). The difference in VD and PD was within 1mm-1 and 1%, respectively. The FAZ area was similar.Conclusions High myopes had more stable fixation when corrected when wearing contact lenses. Subjects with good contact lens corrected visual acuity should wear their contact lenses during OCTA measurements.


F1000Research ◽  
2016 ◽  
Vol 5 ◽  
pp. 2803
Author(s):  
Kareem Allinjawi ◽  
Sharanjeet-Kaur Sharanjeet-Kaur ◽  
Saadah Mohamed Akhir ◽  
Haliza Abdul Mutalib

Aim: The purpose of this study was to determine the changes in the relative peripheral refractive error produced by soft single vision contact lenses in myopic schoolchildren. Methods: 27 myopic schoolchildren aged between 13 to 15 years were included in this study. The measurements of central and peripheral refraction were made only on the right eye using a Grand-Seiko WR-5100K open-field autorefractometer without contact lens (WL), and with wearing single vision contact lens (SVCL). Refractive power was measured at center and horizontal eccentricity between 35° temporal to 35° nasal visual field (in 5° steps). Results: SVCL showed an increase in peripheral hyperopic defocus at the nasal and temporal visual field compare with baseline, but this change was not statistically significant (p=0.129). Conclusion: Wearing single vision soft contact lenses increases the relative peripheral hyperopic defocus in myopic schoolchildren.


2014 ◽  
Vol 5 (1) ◽  
Author(s):  
Aleksandra Debeljković Mitrović ◽  
Dragomir Stamenković ◽  
Manuel Conte ◽  
Božica Bojović ◽  
Spomenko Mihajlović

In this paper results of comparative study of the optical power of soft contact lenses (SCL) made of standard material for SCL and nanophotonic materials with different measurement techniques used for the final contact lens controllers are presented. Three types of nanophotonic soft contact lenses were made of standard polymacon material (Soleko SP38TM) incorporated with fullerene C60, fullerol C60(OH)24 and fullerene metformin hydroxylate C60(OH)12(OC4N5H10)12. For the purposes of material characterization for potential application as soft contact lenses, the optical properties of the soft contact lenses were measured by Rotlex and Nidek device. With Rotlex device the following optical results were obtained: optical power and map of defects, while with the Nidek device: optical power, cylinder power and cylinder axis. The obtained values of optical power and map of defects showed that the optical power of synthesized nanophotonic soft contact lens is same to the nominal value, while this was not the case for the standard soft contact lens. Also, the quality of the nanophotonic soft contact lens is better than the standard one. Hence, it is possible to synthesize new nanophotonic soft contact lenses of desired optical characteristics, implying possibilities for their application in this field.


2013 ◽  
Vol 67 (6) ◽  
pp. 861-870 ◽  
Author(s):  
Aleksandra Debeljkovic ◽  
Lidija Matija ◽  
Djuro Koruga

This work presents comparative research of characteristics of a basic and new nanophotonic material, the latter of which was obtained by incorporation fullerene, C60, in the base material for soft contact lenses. The basic (SL38) and nanophotonic materials (SL38-A) for soft contact lenses were obtained by radical polymerization of 2-hydroxyethyl methacrylate and 2-hydroxyethyl methacrylate and fullerene, which were derived by the technology in the production lab of the company Soleko (Milan, Italy). The materials were used for production of soft contact lenses in the company Optix (Belgrade, Serbia) for the purposes of this research. Fullerene was used due to its apsorption transmission characteristics in ultraviolet, visible and near infrared spectrum. For the purposes of material characterization for potential application as soft contact lenses, network parameters were calculated and SEM analysis of the materials was performed while the optical properties of the soft contact lenses were measured by a Rotlex device. The values of the diffusion exponent, n, close to 0.5 indicated Fick's kinetics corresponding to diffusion. The investigated hydrogels could be classified as nonporous hydrogels. With Rotlex device, values of optical power and map of defects were showed. The obtained values of optical power and map of defects showed that the optical power of synthesized nanophotonic soft contact lens is identical to the nominal value while this was not the case for the basic lens. Also, the quality of the nanophotonic soft contact lens is better than the basic soft contact lens. Hence, it is possible to synthesize new nanophotonic soft contact lenses of desired optical characteristics, implying possibilities for their application in this field.