scholarly journals Comparison of Using One Trabecular Microbypass Stent versus Two during Cataract Surgery at Two Sites: One-Year Follow-Up

2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Shuo Yang ◽  
Mantapond Ittarat ◽  
Elaine Tran ◽  
Patricia Ferrell ◽  
Gloria Wang ◽  
...  

Purpose. To compare IOP and ocular hypotensive medication reduction of using one trabecular microbypass stent versus two in patients with open-angle glaucoma. Setting. Palo Alto Veterans Affairs (VA) Hospital and the Byers Eye Institute at Stanford University, Palo Alto, California, USA. Design. Retrospective case series. Methods. A chart review included patients who underwent trabecular microbypass implantation with cataract surgery in 2015-2017, with at least one-year follow-up. Subjects were divided into two groups by location (always one stent at Stanford versus two stents at the VA). Primary outcome measures included IOP and medication reduction at baseline and 12-month follow-up. Results. 132 subjects (166 eyes) were included. The preoperative IOP was 16.3±3.4 mmHg on 2.6±1.1 medications in the one-stent group (N=85) and 17.5±3.1 mmHg on 2.7±0.6 medications in the two-stent group (N=81). There was no significant difference between the two groups (p=0.06). At the 12-month visit, there was a 13.37%±2.93 reduction in IOP in the 1-stent group (p≤0.001) and 13.49%±2.69 in the 2-stent group (p≤0.001); both were not significantly different from each other (p=0.074). At 12 months, there was also a 14.5% reduction in medication use for the 1-stent group and 15.3% reduction in the 2-stent group, both statistically significant from baseline, (p=0.022 and p=0.037, respectively). Conclusions. Implantation with either one or two stents during cataract surgery in patients with glaucoma demonstrated similar IOP and med reduction in both groups between the two sites.

Author(s):  
Christoph Zanzinger ◽  
Norbert Harrasser ◽  
Oliver Gottschalk ◽  
Patrick Dolp ◽  
Florian Hinterwimmer ◽  
...  

Abstract Background The Cartiva implant (CI) is being increasingly used in the surgical therapy of hallux rigidus. Despite a growing number of studies, numerous questions regarding patient selection remain unanswered. Patients and Methods As part of a retrospective case series with prospective follow-up (average follow-up period: 12 months), a total of 44 patients (male/female = 16/28; mean age at the time of surgery: 55.4 years) with 44 CI were analysed (VAS, EFAS-, AOFAS-score). Using a correlation analysis and a machine learning algorithm, risk factors for therapy failure were investigated. Results The overall survival rate of the CI was 93% at 12 months. The VAS, EFAS and AOFAS scores showed a significant improvement in comparison to the preoperative condition. The mobility of the metatarsophalangeal joint showed no increase. Patients with a medium osteoarthritis grade and a medium level of clinical restraint showed the greatest improvement in relation to their preoperative condition. Conclusion The CI can be seen as an effective therapy for hallux rigidus. Nonetheless, realistic patient expectations must be communicated.


2019 ◽  
Author(s):  
Ye Wu ◽  
Jiaming Chen ◽  
Fuping Xie ◽  
Huanhuan Liu ◽  
Gang Niu ◽  
...  

Abstract Background: The aim of this study was to evaluate the clinical outcome of autotransplantation of mature third molars to fresh molar extraction sockets using 3D replicas. Methods: Ten patients underwent teeth autotransplantation with or without GBR. We observed the mobility, percussion, radiography examination, the probing depth and the masticatory function of the transplanted teeth during two years following up, which were transplanted into fresh molar sockets by using 3D replicas, and GBR when it is necessary. Results: The average extra-oral time of donor tooth had been shortened to 1.65 min when used the 3D replica. Some probing depth of the transplanted tooth were deeper than 3 mm at 4 or 5 weeks temporarily. And one patient felt slight sensitive when chewing with soft food at 4 weeks, then disappeared. The clinical examination of the autotransplantation teeth during one year follow-up showed no sign of failure. Conclusions: The tooth autotransplantation using 3D replica with or without GBR is an effective method which can reduce the extra-oral time of the donor teeth and may result in less failure.


2020 ◽  
Vol 37 (1) ◽  
Author(s):  
Shua Azam ◽  
Abdul Hameed Talpur ◽  
Mahak Shaheen ◽  
Sadia Bukhari

Purpose:  To determine the change in intraocular pressure after cataract surgery in patients diagnosed with glaucoma. Study Design:  Interventional case series. Place and Duration of Study:  Glaucoma Clinic. Al-Ibrahim Eye Hospital (AIEH) Karachi, Pakistan from May to October, 2019. Methods:  Thirty-eight patients diagnosed with glaucoma and cataract and registered in glaucoma clinic were recruited for this study. Inclusion Criteria was age > 41 years and patients diagnosed with primary open/closed angle glaucoma and cataract. Patients with secondary glaucoma, history of trabeculectomy and any other ocular diseases were excluded from the study. Pre-operative assessment was done for phacoemulsification. In post-operative examination, first and second follow-up IOP was measured. Data analysis was done on statistical package for social science (SPSS) version 20.0. Statistical changes were present in the form of bar chart, frequency and graphs. The mean standard deviation for pre-operative, post-operative 1st and 2nd follow-up IOP was calculated. Results:  A total of 38 participants and 48 eyes satisfied the inclusion criteria. Out of 48 eyes, 39 (81.3%) eyes were diagnosed with Primary open angle glaucoma and 9 (18.8%) eyes with Primary Angle Closure Glaucoma. The pre-operative mean IOP was 16.56 ± 6.67 mm Hg and post-operative mean IOP at first follow-up was 13.39 ± 4.04 mm Hg. At second follow-up at one-month mean IOP was 12.14 ± 2.28 mm Hg. Conclusion:  Phacoemulsification produces a useful decrease in IOP in glaucoma patients. Key Word:  Glaucoma, Cataract, Phacoemulsification, Intraocular Pressure.


2021 ◽  
pp. 112067212110334
Author(s):  
Bu Ki Kim ◽  
Young Taek Chung

Purpose: To investigate the clinical outcomes of Visian implantable collamer lens (ICL) implantation according to lens size and implantation angle. Setting: Onnuri Smile Eye Clinic, Seoul, Republic of Korea. Design: Retrospective case series. Methods: This study included 566 eyes of 283 patients treated with ICL implantation. Patients were divided into three groups: horizontally implanted same-sized ICL (group A), horizontally implanted different sized-ICL (group B: large ICL and small ICL) and same sized-ICL implanted with a different implantation angle (group C: horizontal and vertical). Results: At 12-month follow-up, the mean vault was 0.78 ± 17, 0.48 ± 0.13, 0.71 ± 0.18 and 0.44 ± 0.16 mm when large and small sized ICL was used in group B ( p < 0.001), and when ICL was horizontally and vertically implanted in group C ( p = 0.021), respectively. And the mean SE was −0.11 ± 0.30, −0.34 ± 0.42, −0.3 ± 0.56 and −0.64 ± 0.66 dioptres (D), when the large and the small sized ICL was used group B ( p = 0.039), and when the ICL was horizontally and vertically implanted in group C ( p = 0.036), respectively. No significant difference in UDVA, IOP and ECD between both eyes in groups B and C was observed. No statistical difference was found in the vault between both eyes for groups B and C. Conclusions: The vault was significantly higher and the SE was significantly more hyperopic when a larger-sized ICL was used or the ICL was horizontally implanted compared to when the ICL was vertically implanted.


2021 ◽  
pp. 112067212199823
Author(s):  
Iwona Grabska-Liberek ◽  
Patrycja Duda ◽  
Monika Rogowska ◽  
Julita Majszyk- Ionescu ◽  
Agnieszka Skowyra ◽  
...  

Purpose: To characterize clinical outcomes of combined viscodilation of Schlemm’s canal and collector channels and 360° trabeculotomy as a standalone procedure or combined with cataract surgery in eyes with mild to moderate open-angle glaucoma (OAG). Methods: In this prospective case series, the OMNI glaucoma surgical platform (Sight Sciences, Menlo Park, CA) was utilized to perform the procedure either combined with phacoemulsification or as a standalone procedure. Changes from baseline in intraocular pressure (IOP) and IOP-lowering medications were evaluated through the first 12 months of a planned 24-month follow-up period. Results: Among 17 eyes of 15 subjects, mean IOP was reduced from 20.4 mmHg to 12.7–13.7 mmHg through 12 months of follow-up ( p < 0.001 at every time point) and mean medications reduced from 2.5 to 0.1–0.6 ( p < 0.001 at every time point). IOP reductions in eyes undergoing standalone surgery were approximately 2–4 mmHg greater at each time point compared to eyes undergoing surgery combined with phacoemulsification; this may be related to a higher baseline IOP in the former eyes (22.1 vs 18.5 mmHg). Six eyes developed hyphema, of which three required washout for elevated IOP on the first postoperative day; six additional eyes had IOP elevations that resolved with medical management. Conclusion: Viscodilation of Schlemm’s canal and collector channels paired with ab interno trabeculotomy performed with a single integrated instrument (OMNI), whether as standalone or combined with phacoemulsification, effectively lowers both IOP and the need for IOP-lowering medications through 12 months of follow-up.


2019 ◽  
Author(s):  
Ye Wu ◽  
Jiaming Chen ◽  
Fuping Xie ◽  
Huanhuan Liu ◽  
Gang Niu ◽  
...  

Abstract Objective : The aim of this study was to evaluate the clinical outcome of autotransplantation of mature third molars to fresh molar extraction sockets using 3D replicas. Materials and Methods : Ten patients underwent teeth autotransplantation. We observed the mobility, percussion, radiography examination, the probing depth and the masticatory function of the transplanted teeth duringtwo yearsfollowing up, which were transplanted into fresh molar sockets by using 3D replicas, and GBR when it is necessary. Results : The average extra-oral time of donor tooth had been shortened to 1.65 min when used the 3D replica. Some probing depth of the transplanted tooth were deeper than 3 mm at 4 or 5 weeks temporarily. And one patient felt slight sensitive when chewing with soft food at 4 weeks, then disappeared. The clinical examination of the autotransplantation teeth during one year follow-up showed no sign of failure. Conclusions : The tooth autotransplantationusing 3D replica is an effective method which can reduce the extra-oral time of the donor teeth and may result in less failure. Clinical Relevance : The new 3D replica of donor tooth can make the surgery of tooth autotransplantation much easier, and improve it success rate.


2019 ◽  
Author(s):  
Ye Wu ◽  
Jiaming Chen ◽  
Fuping Xie ◽  
Huanhuan Liu ◽  
Gang Niu ◽  
...  

Abstract Background: The aim of this study was to evaluate the clinical outcome of autotransplantation of mature third molars to fresh molar extraction sockets using 3D replicas. Methods: Ten patients underwent teeth autotransplantation with or without GBR. We observed the mobility, percussion, radiography examination, the probing depth and the masticatory function of the transplanted teeth during two years following up, which were transplanted into fresh molar sockets by using 3D replicas, and GBR when it is necessary. Results: The average extra-oral time of donor tooth had been shortened to 1.65 min when used the 3D replica. Some probing depth of the transplanted tooth were deeper than 3 mm at 4 or 5 weeks temporarily. And one patient felt slight sensitive when chewing with soft food at 4 weeks, then disappeared. The clinical examination of the autotransplantation teeth during one year follow-up showed no sign of failure. Conclusions: The tooth autotransplantation using 3D replica with or without GBR is an effective method which can reduce the extra-oral time of the donor teeth and may result in less failure.


2016 ◽  
Vol 41 (1) ◽  
pp. 191-196 ◽  
Author(s):  
Nikolaus Wilhelm Lang ◽  
Roman Christian Ostermann ◽  
Cathrin Arthold ◽  
Julian Joestl ◽  
Patrick Platzer

2020 ◽  
Vol 41 (10) ◽  
pp. 1226-1233
Author(s):  
Juan Manuel Yañez Arauz

Background: Morton’s neuroma is a frequent cause of metatarsalgia. Operative treatment is indicated if nonoperative management has failed. The objective of the present study was to describe a technique of Morton’s neuroma excision by a minimally invasive commissural approach and evaluate the long-term outcome and complications. Methods: A retrospective study of 108 patients with Morton’s neuroma treated surgically with a commissural approach between September 1990 and December 2010 was performed. The surgical technique is described. Clinical outcomes and complications were evaluated. The average follow-up was 121 months. Eleven patients were men and 97 women. The average age was 49.4 years; 56.8% neuromas were at the third space and 43.2% at the second space. Six patients presented 2 neuromas in the same foot, and 9 patients had bilateral neuroma. Results: The visual analog scale (VAS) average pain score was 5.4 points preoperatively and 0.2 points at the final follow-up. The author found a significant difference between the VAS scores preoperatively and postoperatively ( P < .01). Excellent and good satisfaction outcomes were achieved in 93.6%. The postoperative complication incidence was 3%. Conclusion: The author believes a minimally invasive commissural approach has advantages over a dorsal or plantar incision. It is a simple and reproducible technique, with satisfactory outcomes, low complication rates, and a quick return to usual activities. Level of Evidence: Level IV, retrospective case series.


Sign in / Sign up

Export Citation Format

Share Document