scholarly journals Research on Bending Rigidity at Flange Connections of UHV Composite Electrical Equipment

2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Haibo Wang ◽  
Yongfeng Cheng ◽  
Zhicheng Lu ◽  
Zhubing Zhu ◽  
Shujun Zhang

Pillar electrical equipment is an important part of substations. The application of composite materials in pillar equipment can facilitate the improvement of the seismic performance of electrical equipment. In this paper, the test of elastic modulus and bending rigidity was conducted for individual composite elements in insulators and arresters, and the calculation formula for bending rigidity at the composite flange cementing connections was put forward. The numerical simulation model for the earthquake simulation shaking table test of ±1,100 kV composite pillar insulators was established, in which the bending rigidity value for the flange cementing part was obtained by the test or calculation formula. The numerical simulation results were compared with the earthquake simulation shaking table test results, the dynamic characteristics and seismic response of the model were compared, respectively, the validity of the proposed calculation formula for flange bending rigidity of composite cementing parts was verified, and a convenient and effective means was provided for calculating the seismic performance of composite electrical equipment.

2015 ◽  
Vol 1 (6) ◽  
pp. 35-40
Author(s):  
Koichi Isobe ◽  
Hiroki Sugiyama ◽  
Masatsugu Shinohara ◽  
Hiroshi Kobayashi ◽  
Yasuo Sawamura ◽  
...  

Author(s):  
Lina Zong ◽  
Feng Xu ◽  
Wei Yuan ◽  
Xiaolei Ji

Rod element and shell element were used in finite element software ABAQUS to establish dynamic elastic-plastic analysis model of the structure, the seismic performance of an irregular plane complex overrun structure numerical simulation, the structure was calculated under different input level and displacement response of the acceleration response, and analyses the force of the wear layer column and the floor of the open hole stress level. The results were compared with the shaking table test to verify the accuracy of the numerical simulation results. The results of numerical calculation were basically consistent with the experimental results, and the finite element model basically reflected the response of the structure under the simulated earthquake.


2020 ◽  
Vol 48 (2) ◽  
pp. 190-197
Author(s):  
Kyungbeom Jeong ◽  
Satoru Shibuya ◽  
Toshinori Kawabata ◽  
Yutaka Sawada ◽  
Hiroshi Nakazawa

2014 ◽  
Vol 580-583 ◽  
pp. 1463-1466
Author(s):  
Yong Duo Liang ◽  
Xun Guo ◽  
Hua Wei Yi ◽  
Yong Zhen Li ◽  
Jin Zheng Jiang

Bottom-business multi-story masonry structure is widely used in small and middle towns in the southward in China. In the downtown of Beichuan county which affected by Wenchuan earthquake, more than 80% of this kind of building collapsed. But the Apartment of Beichuan Telecommunication Bureau behaved well earthquake resistant capacity with a moderate damage in the earthquake. The obvious difference between this building and others is the setting of winged columns in the front longitudinal wall of the first floor. For proving the influence of these members in the structure seismic capacity, the earthquake simulation shaking table test of 2 1/5 reduced scale models were designed and carried out. The models dynamic response, acceleration, displacement and strain were measured and collected, that model with winged columns behave well was testified. And the reinforcement method of balancing stiffness and increasing ductility is put forward. The results provide a foundation for the retrofitting design of the existing houses.


2015 ◽  
Vol 104 (1) ◽  
pp. 1-8
Author(s):  
Kenichi Tahara ◽  
Yasuhito Sasaki ◽  
Yukihiro Sato ◽  
Satoshi Sasaki ◽  
Shojiro Motoyui

Sign in / Sign up

Export Citation Format

Share Document