scholarly journals Motion Intent Recognition in Intelligent Lower Limb Prosthesis Using One-Dimensional Dual-Tree Complex Wavelet Transforms

2021 ◽  
Vol 2021 ◽  
pp. 1-15
Author(s):  
Min Sheng ◽  
Wan-Jun Wang ◽  
Ting-Ting Tong ◽  
Yuan-Yuan Yang ◽  
Hui-Lin Chen ◽  
...  

The motion intent recognition via lower limb prosthesis can be regarded as a kind of short-term action recognition, where the major issue is to explore the gait instantaneous conversion (known as transitional pattern) between each two adjacent different steady states of gait mode. Traditional intent recognition methods usually employ a set of statistical features to classify the transitional patterns. However, the statistical features of the short-term signals via the instantaneous conversion are empirically unstable, which may degrade the classification accuracy. Bearing this in mind, we introduce the one-dimensional dual-tree complex wavelet transform (1D-DTCWT) to address the motion intent recognition via lower limb prosthesis. On the one hand, the local analysis ability of the wavelet transform can amplify the instantaneous variation characteristics of gait information, making the extracted features of instantaneous pattern between two adjacent different steady states more stable. On the other hand, the translation invariance and direction selectivity of 1D-DTCWT can help to explore the continuous features of patterns, which better reflects the inherent continuity of human lower limb movements. In the experiments, we have recruited ten able-bodied subjects and one amputee subject and collected data by performing five steady states and eight transitional states. The experimental results show that the recognition accuracy of the able-bodied subjects has reached 98.91%, 98.92%, and 97.27% for the steady states, transitional states, and total motion states, respectively. Furthermore, the accuracy of the amputee has reached 100%, 91.16%, and 90.27% for the steady states, transitional states, and total motion states, respectively. The above evidence finally indicates that the proposed method can better explore the gait instantaneous conversion (better expressed as motion intent) between each two adjacent different steady states compared with the state-of-the-art.

2021 ◽  
Vol 2021 ◽  
pp. 1-14
Author(s):  
Dongfang Xu ◽  
Qining Wang

The lower-limb robotic prostheses can provide assistance for amputees’ daily activities by restoring the biomechanical functions of missing limb(s). To set proper control strategies and develop the corresponding controller for robotic prosthesis, a prosthesis user’s intent must be acquired in time, which is still a major challenge and has attracted intensive attentions. This work focuses on the robotic prosthesis user’s locomotion intent recognition based on the noninvasive sensing methods from the recognition task perspective (locomotion mode recognition, gait event detection, and continuous gait phase estimation) and reviews the state-of-the-art intent recognition techniques in a lower-limb prosthesis scope. The current research status, including recognition approach, progress, challenges, and future prospects in the human’s intent recognition, has been reviewed. In particular for the recognition approach, the paper analyzes the recent studies and discusses the role of each element in locomotion intent recognition. This work summarizes the existing research results and problems and contributes a general framework for the intent recognition based on lower-limb prosthesis.


2021 ◽  
Author(s):  
Min Sheng ◽  
Wanjun Wang ◽  
Tingting Tong ◽  
Yuanyuan Yang ◽  
Huilin Chen ◽  
...  

Abstract Background: Most traditional intent recognition methods are to recognizing the movement of lower limb prosthesis through statistical features, which are unstable in short-term signals. The another key problem with recognition of lower limb prosthesis motion intent is to explore the instantaneous change between the two difffferent steady modes. Based on the above considerations, the one-dimensional dual-tree complex wavelet transform(1D-DTCWT) is introduced for motion intent recognition in intelligent prosthesis. Methods: 1D-DTCWT adopts two-way complex wavelet transforms with a binary tree structure as functional data analysis (FDA) method that preserves the time-frequency local analysis capabilities of wavelet transforms while maintaining translation invariance and direction selection. Therefore, the 1D-DTCWT can amplify the instantaneous change information hidden in the data while retaining the continuity of the motion behavior, so as to better recognize the motion intention. Furthermore, the feature vector composed of low-frequency wavelet coeffiffifficients decomposed by 1D-DTCWT is classifified and recognized by support vector machine (SVM), which can effffectively classify and recognize the motion intent of the unilateral lower limb amputees. Results: The data of the experiment comes from ten able-bodied subjects and one amputee subject to analyze 5 steady modes, 8 transitional modes, and 13 total motion modes adopting user-dependent and user-independent methods. The experimental results from the user-dependent methods show that the recognition rate for able-bodied subjects reached 98.91%, 98.92%, and 97.27% for the movement modes of steady modes, transitional modes, and total motion modes, respectively. The recognition rate of the amputee subject reached 100%, 91.16%, and 89.27%, respectively, for the three modes. Conclusions: The method in this paper can effffectively solve the problem of short-term signal instability reflflected by traditional statistical feature recognition of motion intent and explore the instantaneous change information of transitional modes while retaining the continuity of the motion behavior.


2015 ◽  
Vol 9 (1) ◽  
Author(s):  
Jonathan Realmuto ◽  
Glenn Klute ◽  
Santosh Devasia

This article studies the design of passive elastic elements to reduce the actuator requirements for powered ankle prostheses. The challenge is to achieve most of the typically nonlinear ankle response with the passive element so that the active ankle-torque from the actuator can be small. The main contribution of this article is the design of a cam-based lower-limb prosthesis to achieve such a nonlinear ankle response. Results are presented to show that the addition of the cam-based passive element can reduce the peak actuator torque requirement substantially, by ∼74%. Moreover, experimental results are presented to demonstrate that the cam-based design can achieve a desired nonlinear response to within 10%.


2018 ◽  
Vol 43 (3) ◽  
pp. 257-265 ◽  
Author(s):  
Saffran Möller ◽  
David Rusaw ◽  
Kerstin Hagberg ◽  
Nerrolyn Ramstrand

Background: Individuals using a lower-limb prosthesis indicate that they need to concentrate on every step they take. Despite self-reports of increased cognitive demand, there is limited understanding of the link between cognitive processes and walking when using a lower-limb prosthesis. Objective: The objective was to assess cortical brain activity during level walking in individuals using different prosthetic knee components and compare them to healthy controls. It was hypothesized that the least activity would be observed in the healthy control group, followed by individuals using a microprocessor-controlled prosthetic knee and finally individuals using a non-microprocessor-controlled prosthetic knee. Study design: Cross-sectional study. Methods: An optical brain imaging system was used to measure relative changes in concentration of oxygenated and de-oxygenated haemoglobin in the frontal and motor cortices during level walking. The number of steps and time to walk 10 m was also recorded. The 6-min walk test was assessed as a measure of functional capacity. Results: Individuals with a transfemoral or knee-disarticulation amputation, using non-microprocessor-controlled prosthetic knee ( n = 14) or microprocessor-controlled prosthetic knee ( n = 15) joints and healthy controls ( n = 16) participated in the study. A significant increase was observed in cortical brain activity of individuals walking with a non-microprocessor-controlled prosthetic knee when compared to healthy controls ( p < 0.05) and individuals walking with an microprocessor-controlled prosthetic knee joint ( p < 0.05). Conclusion: Individuals walking with a non-microprocessor-controlled prosthetic knee demonstrated an increase in cortical brain activity compared to healthy individuals. Use of a microprocessor-controlled prosthetic knee was associated with less cortical brain activity than use of a non-microprocessor-controlled prosthetic knee. Clinical relevance Increased understanding of cognitive processes underlying walking when using different types of prosthetic knees can help to optimize selection of prosthetic components and provide an opportunity to enhance functioning with a prosthesis.


Sign in / Sign up

Export Citation Format

Share Document