ankle torque
Recently Published Documents


TOTAL DOCUMENTS

70
(FIVE YEARS 24)

H-INDEX

15
(FIVE YEARS 2)

Sensors ◽  
2021 ◽  
Vol 22 (1) ◽  
pp. 135
Author(s):  
Iulia Iovanca Drăgoi ◽  
Florina Georgeta Popescu ◽  
Teodor Petrița ◽  
Romulus Fabian Tatu ◽  
Cosmina Ioana Bondor ◽  
...  

Custom-made dynamometry was shown to objectively analyze human muscle strength around the ankle joint with accuracy, easy portability and low costs. This paper describes the full method of calibration and measurement setup and the measurement procedure when capturing ankle torque for establishing reliability of a portable custom-built electronic dynamometer. After considering the load cell offset voltage, the pivotal position was determined, and calibration with loads followed. Linear regression was used for calculating the proportionality constant between torque and measured voltage. Digital means were used for data collection and processing. Four healthy consenting participants were enrolled in the study. Three consecutive maximum voluntary isometric contractions of five seconds each were registered for both feet during plantar flexion/dorsiflexion, and ankle torque was then calculated for three ankle inclinations. A calibration procedure resulted, comprising determination of the pivotal axis and pedal constant. Using the obtained data, a measurement procedure was proposed. Obtained contraction time graphs led to easier filtering of the results. When calculating the interclass correlation, the portable apparatus demonstrated to be reliable when measuring ankle torque. When a custom-made dynamometer was used for capturing ankle torque, accuracy of the method was assured by a rigorous calibration and measurement protocol elaboration.


Author(s):  
Krithika Swaminathan ◽  
Sungwoo Park ◽  
Fouzia Raza ◽  
Franchino Porciuncula ◽  
Sangjun Lee ◽  
...  

Abstract Background Ankle-targeting resistance training for improving plantarflexion function during walking increases rehabilitation intensity, an important factor for motor recovery after stroke. However, understanding of the effects of resisting plantarflexion during stance on joint kinetics and muscle activity—key outcomes in evaluating its potential value in rehabilitation—remains limited. This initial study uses a unilateral exosuit that resists plantarflexion during mid-late stance in unimpaired individuals to test the hypotheses that when plantarflexion is resisted, individuals would (1) increase plantarflexor ankle torque and muscle activity locally at the resisted ipsilateral ankle, but (2) at higher forces, exhibit a generalized response that also uses the unresisted joints and limb. Further, we expected (3) short-term retention into gait immediately after removal of resistance. Methods Ten healthy young adults walked at 1.25 m s−1 for four 10-min discrete bouts, each comprising baseline, exposure to active exosuit-applied resistance, and post-active sections. In each bout, a different force magnitude was applied based on individual baseline ankle torques. The peak resistance torque applied by the exosuit was 0.13 ± 0.01, 0.19 ± 0.01, 0.26 ± 0.02, and 0.32 ± 0.02 N m kg−1, in the LOW, MED, HIGH, and MAX bouts, respectively. Results (1) Across all bouts, participants increased peak ipsilateral biological ankle torque by 0.13–0.25 N m kg−1 (p < 0.001) during exosuit-applied resistance compared to corresponding baselines. Additionally, ipsilateral soleus activity during stance increased by 5.4–11.3% (p < 0.05) in all but the LOW bout. (2) In the HIGH and MAX bouts, vertical ground reaction force decreased on the ipsilateral limb while increasing on the contralateral limb (p < 0.01). Secondary analysis found that the force magnitude that maximized increases in biological ankle torque without significant changes in limb loading varied by subject. (3) Finally, peak ipsilateral plantarflexion angle increased significantly during post-exposure in the intermediate HIGH resistance bout (p < 0.05), which corresponded to the greatest average increase in soleus activity (p > 0.10). Conclusions Targeted resistance of ankle plantarflexion during stance by an exosuit consistently increased local ipsilateral plantarflexor effort during active resistance, but force magnitude will be an important parameter to tune for minimizing the involvement of the unresisted joints and limb during training.


Machines ◽  
2021 ◽  
Vol 9 (8) ◽  
pp. 154
Author(s):  
Luís Moreira ◽  
Joana Figueiredo ◽  
João Paulo Vilas-Boas ◽  
Cristina Peixoto Santos

Powered Assistive Devices (PADs) have been proposed to enable repetitive, user-oriented gait rehabilitation. They may include torque controllers that typically require reference joint torque trajectories to determine the most suitable level of assistance. However, a robust approach able to automatically estimate user-oriented reference joint torque trajectories, namely ankle torque, while considering the effects of varying walking speed, body mass, and height on the gait dynamics, is needed. This study evaluates the accuracy and generalization ability of two Deep Learning (DL) regressors (Long-Short Term Memory and Convolutional Neural Network (CNN)) to generate user-oriented reference ankle torque trajectories by innovatively customizing them according to the walking speed (ranging from 1.0 to 4.0 km/h) and users’ body height and mass (ranging from 1.51 to 1.83 m and 52.0 to 83.7 kg, respectively). Furthermore, this study hypothesizes that DL regressors can estimate joint torque without resourcing electromyography signals. CNN was the most robust algorithm (Normalized Root Mean Square Error: 0.70 ± 0.06; Spearman Correlation: 0.89 ± 0.03; Coefficient of Determination: 0.91 ± 0.03). No statistically significant differences were found in CNN accuracy (p-value > 0.05) whether electromyography signals are included as inputs or not, enabling a less obtrusive and accurate setup for torque estimation.


2021 ◽  
Author(s):  
Gwendolyn M Bryan ◽  
Patrick W. Franks ◽  
Seungmoon Song ◽  
Alexandra S Voloshina ◽  
Ricardo Reyes ◽  
...  

Background: Effective autonomous exoskeletons will need to be useful at a variety of walking speeds, but we do not know how optimal exoskeleton assistance should change with speed. Optimal exoskeleton assistance may increase with speed similar to biological torque changes or a well-tuned assistance profile may be effective at a variety of speeds. Methods: We optimized hip-knee-ankle exoskeleton assistance to reduce metabolic cost for three participants walking at 1.0 m/s, 1.25 m/s and 1.5 m/s. We measured metabolic cost, muscle activity, exoskeleton assistance and kinematics. We performed two tailed paired t-tests to determine significance. Results: Exoskeleton assistance reduced the metabolic cost of walking compared to wearing the exoskeleton with no torque applied by 26%, 47% and 50% at 1.0, 1.25 and 1.5 m/s, respectively. For all three participants, optimized exoskeleton ankle torque was the smallest for slow walking, while hip and knee torque changed slightly with speed in ways that varied across participants. Total applied positive power increased with speed for all three participants, largely due to increased joint velocities, which consistently increased with speed. Conclusions: Exoskeleton assistance is effective at a range of speeds and is most effective at medium and fast walking speeds. Exoskeleton assistance was less effective for slow walking, which may explain the limited success in reducing metabolic cost for patient populations through exoskeleton assistance. Exoskeleton designers may have more success when targeting activities and groups with faster walking speeds. Speed-related changes in optimized exoskeleton assistance varied by participant, indicating either the benefit of participant-specific tuning or that a wide variety of torque profiles are similarly effective.


PLoS ONE ◽  
2021 ◽  
Vol 16 (1) ◽  
pp. e0244993
Author(s):  
Tania E. Sakanaka ◽  
Martin Lakie ◽  
Raymond F. Reynolds

When standing, intrinsic ankle stiffness is smaller when measured using large perturbations, when sway size is large, and when background torque is low. However, there is a large variation in individual intrinsic ankle stiffness. Here we determine if individual variation has consequences for postural control. We examined the relationship between ankle stiffness, ankle torque and body sway across different individuals. Ankle stiffness was estimated in 19 standing participants by measuring torque responses to small, brief perturbations. Perturbation sizes of 0.2 & 0.9 degrees (both lasting 140 ms) measured short- and long-range stiffness respectively, while participants either stood quietly on a fixed platform or were imperceptibly tilted to reduce stability (0.1 Hz sinusoid; 0.2 & 0.4 deg). The spontaneous body sway component (natural random relatively rapid postural adjustments) and background ankle torque were averaged from sections immediately before perturbations. The results show that, first, intrinsic ankle stiffness is positively associated with ankle torque, and that this relationship is stronger for long-range stiffness. Second, intrinsic ankle stiffness is negatively associated with body sway, but, in contrast to the relationship with torque, this relationship is stronger for short-range stiffness. We conclude that high short-range intrinsic ankle stiffness is associated with reduced spontaneous sway, although the causal relationship between these two parameters is unknown. These results suggest that, in normal quiet standing where sway is very small, the most important determinant of intrinsic ankle stiffness may be stillness. In less stable conditions, intrinsic ankle stiffness may be more dependent on ankle torque.


2021 ◽  
Vol 8 (1) ◽  
pp. 201235
Author(s):  
Vincent L. Chiu ◽  
Alexandra S. Voloshina ◽  
Steven H. Collins

Over half of individuals with a lower-limb amputation are unable to walk on uneven terrain. Using a prosthesis emulator system, we developed an irregularity-cancelling controller intended to reduce the effect of disturbances resulting from uneven surfaces. This controller functions by changing the neutral angles of two forefoot digits in response to local terrain heights. To isolate the effects of the controller, we also programmed a spring-like controller that maintained fixed neutral angles. Five participants with transtibial amputation walked on a treadmill with an uneven walking surface. Compared with the spring-like controller, the irregularity-cancelling controller reduced ankle torque variability by 41% in the sagittal plane and 64% in the frontal plane. However, user outcomes associated with balance were mostly unaffected; only trunk movement variability was reduced, whereas metabolic rate, mediolateral centre of mass motion, and variabilities in step width, step length and step time were unchanged. We conclude that reducing ankle torque variability of the affected limb is not sufficient for reducing the overall effect of disturbances due to uneven terrain. It is possible that other factors, such as changes in step height or disturbances to the intact limb, play a larger role in difficulty balancing while walking over uneven surfaces.


Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5806
Author(s):  
Stefano Alleva ◽  
Michele Gabrio Antonelli ◽  
Pierluigi Beomonte Zobel ◽  
Francesco Durante

Powered ankle-foot prostheses for walking often have limitations in the range of motion and in push-off power, if compared to a lower limb of a healthy person. A new design of a powered ankle-foot prosthesis is proposed to obtain a wide range of motion and an adequate power for a push-off step. The design methodology for this prosthesis has three points. In the first one, a dimensionless kinematic model of the lower limb in the sagittal plane is built, through an experimental campaign with healthy subjects, to calculate the angles of lower limb during the gait. In the second point a multibody inverse dynamic model of the lower limb is constructed to calculate the foot-ground contact force, its point of application and the ankle torque too, entering as input data the calculated angles of the lower limb in the previous point. The third point requires, as input of the inverse dynamic model, the first dimensioning data of the ankle-foot prosthesis to obtain the load acting on the components of the prosthesis and the angle torque of the actuator during the gait cycle. Finally, an iteration cycle begins with the inverse dynamic model modifying the ankle torque and angle until these quantities during the gait are as close as possible to the physiological quantities. After the mechanical design and the construction of the prototype of the prosthesis, an experimental methodology was used for preliminary validation of the design. The preliminary tests in the laboratory on the prototype alone show that the range of motion of the ankle angle during the gait is close to a healthy person’s: 27.6° vs. 29°. The pushing force of the distal area of the prototype is 1.000 N, instead of 1.600 N, because a budget reduction forced us to choose components for the prototype with lower performance.