scholarly journals Assessing the Applicability of Photocatalytic-Concrete Blocks in Reducing the Concentration of Ambient NO2 of Chandigarh, India, Using Box–Behnken Response Surface Design Technique: A Holistic Sustainable Development Approach

2021 ◽  
Vol 2021 ◽  
pp. 1-12
Author(s):  
Neeru Singla ◽  
Sandeep Singla ◽  
Parteek Singh Thind ◽  
Sandeep Singh ◽  
Jasgurpreet Singh Chohan ◽  
...  

Anthropogenic emissions, such as industrial, vehicular, biomass burning, and coal combustion, play a significant role in degrading the atmospheric conditions of India. Therefore, in the present study, applicability of the photocatalytic-concrete blocks was estimated in improving the ambient environment of Chandigarh, India. The photocatalytic-concrete blocks were prepared by mixing the TiO2 particles with cement. All the experiments, designed in accordance with the Box–Behnken approach, in combination with response surface methodology, were performed in a batch reactor. Further, the process parameters, namely, concentration of TiO2 (1 to 5 g), UV-A irradiance (1 to 5 mW/cm2), and relative humidity (RH) (10 to 70%), were optimized to achieve maximum degradation of NO2. Outcomes of batch experiments depicted that the maximum degradation of NO2, that is, 68.32%, was attained at 3.35 g of TiO2, 5 mW/cm2 of UV-A irradiance, and 64.60% RH. The findings of batch experiment were further theoretically applied to degrade the ambient NO2 concentration of Chandigarh, India. It was estimated that using the photocatalytic concrete for construction of Chandigarh’s pavements may reduce the ambient NO2 concentration of Chandigarh, India, to an average of 5.80 μg/m3. Afterwards, reusability of photocatalytic-concrete blocks was also assessed, and it was made evident that after five cycles, their efficiency was reduced by only 7.15%. Subsequently, it was revealed that hydrogen peroxide-based treatment of photocatalytic-concrete blocks could completely regenerate its treatment efficiency. Therefore, it is expected that the findings of this study may prove beneficial in urban planning, as it may assist scientific auditory in identifying the applicability of TiO2-based photocatalysis in mitigating the impacts of vehicular emissions.

2021 ◽  
pp. 1-37
Author(s):  
Ana Gabriela Sierra-Sánchez ◽  
Verónica Martínez-Miranda ◽  
Elia Alejandra Teutli-Sequeira ◽  
Ivonne Linares-Hernández ◽  
Guadalupe Vázquez-Mejía ◽  
...  

2011 ◽  
Vol 295-297 ◽  
pp. 1860-1865 ◽  
Author(s):  
Zhi Zhang ◽  
Chao Liu ◽  
Gong Duan Fan ◽  
Jing Luo ◽  
Yan Dong Wang

The control parameters of the removal of Chlorella pyrenoidosa, which was irradiated by low frequency ultrasonic, is optimized by using single factor experiments and response surface methodology (RSM). First of all, the approximate ranges of the ultrasonic frequency, the ultrasonic power and the irradiation time were estimated with single factor experiments for the further experiments. And then the optimized values of the three control parameters were determined, which were analyzed by using central composite design (CCD) and RSM. The results showed that the removal rate of chlorophyll-a could reach to 64.1% after the irradiation for 6.34min by using ultrasonic of 77.7 kHz and 250W. Ultrasonic technology can remove Chlorella pyrenoidosa cells in water quickly and effectively, so as to achieve the purpose of water purification.


Author(s):  
Vijay A. Juwar ◽  
Ajit P. Rathod

Abstract The present study deals with the treatment of complex waste (WW) treated for removal of chemical oxygen demand (COD) of the food industry by a sono-Fenton process using a batch reactor. The response surface methodology (RSM) was employed to investigate the five independent variables, such as reaction time, the molar ratio of H2O2/Fe2+, volume ratio of H2O2/WW, pH of waste, and ultrasonic density on COD removal. The experimental data was optimized. The optimization yields the conditions: Reaction time of 24 min, HP:Fe molar ratio of 2.8, HP:WW volume ratio of 1.9 ml/L, pH of 3.6 and an ultrasonic density of 1.8 W/L. The predicted value of COD was 91% and the experimental result was 90%. The composite desirability value (D) of the predicted percent of COD removal at the optimized level of variables was close to one (D = 0.991).


2000 ◽  
Vol 42 (5-6) ◽  
pp. 171-178 ◽  
Author(s):  
S.-R. Ha ◽  
L. Qishan ◽  
S. Vinitnantharat

Treatment performance of COD in the presence of 2,4-dichlorophenol (2,4-DCP) was explored by using a biological activated carbon-sequencing batch reactor (BAC-SBR) system. Two COD levels of basic substrate were synthesized with a mixture of phenol and 2,4-dichlorophenol. Although effluent concentration was increased with reduction of sludge retention time (SRT) from 8-days to 3-days, treatment efficiency was indicated more than 90% of COD in all SRTs applied. Reactors operated with acclimated sludge could be expected to cope with quite high loading of inhibitory substances.


Sign in / Sign up

Export Citation Format

Share Document