scholarly journals The Investigation on Heat Transfer Characteristics of Steam Condensation in Presence of Noncondensable Gas under Natural Convection

2021 ◽  
Vol 2021 ◽  
pp. 1-13
Author(s):  
Xizhen Ma ◽  
Jiang Ma ◽  
Heng Tong ◽  
Haijun Jia

The NHR-200 reactor in China adopts the noncondensable gas self-stabilizing control and the noncondensable gas used for pressure stabilization control can weaken steam condensation heat transfer in the integrated steam-gas pressurizer. A condensation experimental system was established and the heat transfer characteristics of steam-nitrogen and steam-argon condensation under natural convection had been investigated. The pressure ranged from 0.516 to 5.10 MPa. The distributions of nitrogen and argon in the steam/gas mixture were obtained in the experiments, and the results showed that nitrogen and argon were evenly distributed in the steam under different pressure, respectively. The effects of heat transfer temperature difference had also been investigated and it is found that the total heat transfer coefficient difference had little influence on the total condensation heat transfer coefficient. However, the steam condensation heat transfer coefficient decreased with the increase of the degree of supercooling of the wall. The condensation heat transfer coefficient was reduced by approximately 0.11 kW/(m2·K) as the degree of supercooling of the wall changed from 14°C to 36°C. The condensation heat transfer coefficient also decreased with the mass/molar fraction of noncondensable gas increasing and a certain difference between the effect of the mass fraction of noncondensable gas and the effect of the molar fraction of noncondensable gas was discussed in this paper.

2020 ◽  
Vol 24 (06) ◽  
pp. 115-126
Author(s):  
Mohammed Ghazi M. Kamil ◽  
◽  
Muna Sabah Kassim ◽  
Louay Abd Alazez Mahdi ◽  
◽  
...  

The heat transfer coefficient of steam condensation has a significant role in the performance of air-cooled heat exchangers. The purpose of this work is to predict the local/average local steam condensation heat transfer coefficient inside the horizontal flattened tube under vacuum conditions using numerous correlations that were developed by some researches which have been conducted under specified conditions. The results from these correlations have been compared with experimental data of Davies, therefore more investigate for the values are necessary to improve or/and validate the existing correlations. The effect of such parameters like the uniform heat flux and saturation temperature also have been studied on the local steam condensation heat transfer coefficient as the results show that the heat transfer coefficient decrease as the heat flux increase, while it increases as the steam saturated temperature increase.


2000 ◽  
Vol 122 (3) ◽  
pp. 613-620 ◽  
Author(s):  
Z. Guo ◽  
N. K. Anand

An analytical model to predict condensation heat transfer coefficient in a horizontal rectangular channel was developed. The total local condensation heat transfer coefficient was represented as the weighted average of heat transfer coefficients for each wall. The analytical predictions compared well with the experimental data on the condensation of R-410A in a rectangular channel. The mean deviation was 6.75 percent. [S0022-1481(00)00503-X]


2008 ◽  
Author(s):  
Pradeep A. Patil ◽  
S. N. Sapali

An experimental test facility is designed and built to calculate condensation heat transfer coefficients and pressure drops for HFC-134a, R-404A, R-407C, R-507A in a smooth and micro-fin tube. The main objective of the experimentation is to investigate the enhancement in condensation heat transfer coefficient and increase in pressure drop using micro-fin tube for different condensing temperatures and further to develop an empirical correlation for heat transfer coefficient and pressure drop, which takes into account the micro-fin tube geometry, variation of condensing temperature and temperature difference (difference between condensing temperature and average temperature of cooling medium). The experimental setup has a facility to vary the different operating parameters such as condensing temperature, cooling water temperature, flow rate of refrigerant and cooling water etc and study their effect on heat transfer coefficients and pressure drops. The hermetically sealed reciprocating compressor is used in the system, thus the effect of lubricating oil on the heat transfer coefficient is taken in to account. This paper reports the detailed description of design and development of the test apparatus, control devices, instrumentation, and the experimental procedure. It also covers the comparative study of experimental apparatus with the existing one from the available literature survey. The condensation and pressure drop of HFC-134a in a smooth tube are measured and obtained the values of condensation heat transfer coefficients for different mass flux and condensing temperatures using modified Wilson plot technique with correlation coefficient above 0.9. The condensation heat transfer coefficient and pressure drop increases with increasing mass flux and decreases with increasing condensing temperature. The results are compared with existing available correlations for validation of test facility. The experimental data points have good association with available correlations except Cavallini-Zecchin Correlation.


Author(s):  
Wei Li ◽  
Dan Huang ◽  
Zan Wu ◽  
Hong-Xia Li ◽  
Zhao-Yan Zhang ◽  
...  

An experimental investigation was performed for convective condensation of R410A inside four micro-fin tubes with the same outside diameter (OD) 5 mm and helix angle 18°. Data are for mass fluxes ranging from about 180 to 650 kg/m2s. The nominal saturation temperature is 320 K, with inlet and outlet qualities of 0.8 and 0.1, respectively. The results suggest that Tube 4 has the best thermal performance for its largest condensation heat transfer coefficient and relatively low pressure drop penalty. Condensation heat transfer coefficient decreases at first and then increases or flattens out gradually as G decreases. This complex mass-flux effect may be explained by the complex interactions between micro-fins and fluid. The heat transfer enhancement mechanism is mainly due to the surface area increase over the plain tube at large mass fluxes, while liquid drainage and interfacial turbulence play important roles in heat transfer enhancement at low mass fluxes. In addition, the experimental data was analyzed using seven existing pressure-drop and four heat-transfer models to verify their respective accuracies.


2008 ◽  
Author(s):  
Tailian Chen

Prediction of condenser bundle performance is of great interest to chiller design engineers and tube developers as well. Depending on their locations in a condenser bundle, tubes are subjected to inundation or flooding of condensate coming from those above them. The tubes located in the top portion of the bundle are not or slightly inundated whereas the tubes located deep in the bundle experience larger degree of inundation; those in the bundle bottom are the most severely inundated. For a condenser bundle to have good performance, it is necessary for the tubes to perform well in both non-inundated and inundated conditions. In this paper, the outside condensation heat transfer coefficient and its sensitivity to inundation for a condenser tube of enhanced 3-dimensional (3D) outside fins were measured. Based on the single tube measurements, shell side condensation performance of a condenser bundle was predicted. The predicted bundle outside heat transfer coefficient has a reasonable agreement with that of a condenser tested in a 500-ton chiller.