CamGFR v2: a new model for estimating the glomerular filtration rate from standardized or non-standardized creatinine in patients with cancer

2020 ◽  
pp. clincanres.3201.2020
Author(s):  
Edward H. Williams ◽  
Thomas R. Flint ◽  
Claire M Connell ◽  
Daniel Giglio ◽  
Hassal Lee ◽  
...  
2017 ◽  
Vol 35 (15_suppl) ◽  
pp. e14074-e14074
Author(s):  
Tobias Janowitz ◽  
Edward Hywel Williams ◽  
Andrea Marshall ◽  
Nicola Ainsworth ◽  
Peter B Thomas ◽  
...  

e14074 Background: The glomerular filtration rate (GFR) is essential for carboplatin chemotherapy dosing, however, the best method to estimate GFR in patients with cancer is unknown. We identify the most accurate and least biased method. Methods: Data on age, sex, height, weight, serum creatinine, and results for GFR from 51Cr-EDTA excretion measurements (51Cr-EDTA GFR) were obtained from Caucasian patients aged 18 years or older with histologically confirmed cancer diagnoses at the University of Cambridge Hospital NHS Trust, UK. We developed a new multivariable linear model for GFR using statistical regression analysis. 51Cr-EDTA GFR was compared to the estimated GFR (eGFR) from seven published and our new model using an internal validation data set and root-mean-squared-error (RMSE) and median residuals. A comparison of carboplatin dosing accuracy based on an absolute percentage error more than 20% (APE > 20%) was undertaken. Results: Between August 2006 and January 2013 data from 2,471 patients were obtained. The new model improved the eGFR accuracy (RMSE 15.00ml/min (95% CI 14.12-16.00)) compared to all published models. Body surface area (BSA) adjusted CKD-EPI was the most accurate published models for eGFR (RMSE 16.30ml/min (95% CI 15.34-17.38)) for the internal validation set. Importantly, the new model reduced the fraction of patients with a carboplatin dose APE > 20% to 14.17% in contrast to 18.62% for BSA adjusted CKD-EPI and 25.51% for the Cockcroft-Gault model. The results were externally validated. Conclusions: In a large data set, from patients with cancer, a new model improves eGFR and carboplatin dose calculations, when compared to BSA adjusted CKD-EPI, the model we identified as the best published model for determination of eGFR in patients with cancer.


2018 ◽  
Vol 36 (15_suppl) ◽  
pp. 2565-2565
Author(s):  
Edward Williams ◽  
Reed Stratton Geisler ◽  
Ian Beh ◽  
Gianfilippo Bertelli ◽  
Richard Cathomas ◽  
...  

2017 ◽  
Vol 35 (24) ◽  
pp. 2798-2805 ◽  
Author(s):  
Tobias Janowitz ◽  
Edward H. Williams ◽  
Andrea Marshall ◽  
Nicola Ainsworth ◽  
Peter B. Thomas ◽  
...  

Purpose The glomerular filtration rate (GFR) is essential for carboplatin chemotherapy dosing; however, the best method to estimate GFR in patients with cancer is unknown. We identify the most accurate and least biased method. Methods We obtained data on age, sex, height, weight, serum creatinine concentrations, and results for GFR from chromium-51 (51Cr) EDTA excretion measurements (51Cr-EDTA GFR) from white patients ≥ 18 years of age with histologically confirmed cancer diagnoses at the Cambridge University Hospital NHS Trust, United Kingdom. We developed a new multivariable linear model for GFR using statistical regression analysis. 51Cr-EDTA GFR was compared with the estimated GFR (eGFR) from seven published models and our new model, using the statistics root-mean-squared-error (RMSE) and median residual and on an internal and external validation data set. We performed a comparison of carboplatin dosing accuracy on the basis of an absolute percentage error > 20%. Results Between August 2006 and January 2013, data from 2,471 patients were obtained. The new model improved the eGFR accuracy (RMSE, 15.00 mL/min; 95% CI, 14.12 to 16.00 mL/min) compared with all published models. Body surface area (BSA)–adjusted chronic kidney disease epidemiology (CKD-EPI) was the most accurate published model for eGFR (RMSE, 16.30 mL/min; 95% CI, 15.34 to 17.38 mL/min) for the internal validation set. Importantly, the new model reduced the fraction of patients with a carboplatin dose absolute percentage error > 20% to 14.17% in contrast to 18.62% for the BSA-adjusted CKD-EPI and 25.51% for the Cockcroft-Gault formula. The results were externally validated. Conclusion In a large data set from patients with cancer, BSA-adjusted CKD-EPI is the most accurate published model to predict GFR. The new model improves this estimation and may present a new standard of care.


2019 ◽  
Vol 3 (4) ◽  
Author(s):  
Edward H Williams ◽  
Claire M Connell ◽  
James M J Weaver ◽  
Ian Beh ◽  
Harry Potts ◽  
...  

Abstract Important oncological management decisions rely on kidney function assessed by serum creatinine–based estimated glomerular filtration rate (eGFR). However, no large-scale multicenter comparisons of methods to determine eGFR in patients with cancer are available. To compare the performance of formulas for eGFR based on routine clinical parameters and serum creatinine not calibrated with isotope dilution mass spectrometry, we studied 3620 patients with cancer and 166 without cancer who had their glomerular filtration rate (GFR) measured with an exogenous nuclear tracer at one of seven clinical centers. The mean measured GFR was 86 mL/min. Accuracy of all models was center dependent, reflecting intercenter variability of isotope dilution mass spectrometry–creatinine measurements. CamGFR was the most accurate model for eGFR (root-mean-squared error 17.3 mL/min) followed by the Chronic Kidney Disease Epidemiology Collaboration model (root-mean-squared error 18.2 mL/min).


2018 ◽  
Vol 38 (3) ◽  
pp. 261-265 ◽  
Author(s):  
Tae-Dong Jeong ◽  
Jaeryuk Kim ◽  
Woochang Lee ◽  
Sail Chun ◽  
Ki-Sook Hong ◽  
...  

1971 ◽  
Vol 10 (01) ◽  
pp. 16-24
Author(s):  
J. Fog Pedersen ◽  
M. Fog Pedersen ◽  
Paul Madsen

SummaryAn accurate catheter-free technique for clinical determination simultaneouslyof glomerular filtration rate and effective renal plasma flow by means of radioisotopes has been developed. The renal function is estimated by the amount of radioisotopes necessary to maintain a constant concentration in the patient’s blood. The infusion pumps are steered by a feedback system, the pumps being automatically turned on when the radiation measured over the patient’s head falls below a certain preset level and turned off when this level is again readied. 131I-iodopyracet was used for the estimation of effective renal plasma flow and125I-iothalamate estimation of the glomerular filtration rate. These clearances were compared to the conventional bladder clearances and good correlation was found between these two clearance methods (correlation coefficients 0.97 and.90 respectively). The advantages and disadvantages of this new clearance technique are discussed.


Sign in / Sign up

Export Citation Format

Share Document