Large Urethro-Vesico-Vaginal Fistula due to a Vaginal Foreign Body in a 22-Year-Old Woman: Case Report and Literature Review

2014 ◽  
Vol 95 (1) ◽  
pp. 120-124 ◽  
Author(s):  
Carolina D'Elia ◽  
Pierpaolo Curti ◽  
Maria Angela Cerruto ◽  
Carmelo Monaco ◽  
Walter Artibani

In the non-industrialized countries of Africa and Asia obstetric fistulas are more frequently caused by prolonged labour, whereas in countries with developed healthcare systems they are generally the result of complications of gynaecological surgery or, rarely, benign pathologies like inflammation or foreign bodies. A 22-year-old woman was brought to the gynaecology clinic because of foul-smelling vaginal discharge. On pelvic examination a ring-like foreign body was impacted between the anterior and posterior vaginal wall. MRI scan confirmed the presence of a cylindrical foreign body in the vagina and the patient revealed that she had ‘involuntarily' inserted a plastic bubble bath cap into the vagina. At surgery removal of the cap was difficult and at the end of the manoeuver evidence of a huge urethro-vesico-vaginal fistula occurred. The patient was discharged with bilateral ureteral stents and suprapubic catheter. After 3 months we performed an end-to-end anastomotic urethroplasty to repair the urethral avulsion and restored the bladder/trigonal and vaginal/cervical defects with 3 layers of sutures; 3 months later the patient had no complaints. Complex genital fistulas represent an extremely debilitating morbidity. In our case, a vaginal approach was successful, but the choice between an abdominal or vaginal approach depends on the surgeon's experience and training.

1988 ◽  
Vol 62 (3) ◽  
pp. 271-271 ◽  
Author(s):  
M. N. MHIRI ◽  
A. AMOUS ◽  
M. MEZGHANNI ◽  
S. REKIK ◽  
M. L. SMIDA

Swiss Surgery ◽  
2001 ◽  
Vol 7 (3) ◽  
pp. 139-140 ◽  
Author(s):  
Halkic ◽  
Wisard ◽  
Abdelmoumene ◽  
Vuilleumier

All manner of foreign bodies have been extracted from the bladder. Introduction into the bladder may be through self-insertion, iatrogenic means or migration from adjacent organs. Extraction should be tailored according to the nature of the foreign body and should minimise bladder and urethral trauma. We report a case of a bullet injury to the bladder, which finally presented as a gross hematuria after remaining asymptomatic for four years. We present here an alternative to suprapubic cystostomy with a large bladder foreign body treated via a combined transurethral unroofing followed by removal using a grasper passed through a suprapubic laparoscopic port.


2016 ◽  
pp. 63-69
Author(s):  
Hoang Cuong Vo ◽  
Thanh Dang ◽  
Phuong Nam Tran ◽  
Thanh Thai Le

Background: Foreign bodies ingestion is a emergency in otology, knowledge of people about foreign bodies ingestion is not enough. Objective: To study the clinical characteristics, paraclinical characteristics and results of treatment from foreign bodies ingestion in Hue Central Hospital and Hue University Hospital. Methods and patiens: A cross descriptive and prospective study over the period from 6/2014 to 5/2016, total are 137 patients come to be diagnosised and treatmented. Results: the average age is 35 years old. Gender: male (51.8%) and women (48.2%). Adults (84.7%) having more than children (15.3%). Age group from 16-30 years is highest (32.8%). There are 95.7% of organic foreign bodies, 4.3% are inorganic foreign bodies. There are 90.5% of patients on diagnosis and treatment in stages less inflammation, arthritis 8.0% in the period and 1.5% in the period complications. Foreign body in the throat problems (73.7%), esophageal foreign bodies (26.3%). Pick up directly foreign bodies 54%, indirectly by the mirror 11.7% and endoscopy 8%, rigid esophagoscopy is 17.5%, flexible esophagoscopy is 7.3%, cervicotomy is 1.5%. Conclusion: Practing direction with in the oropharynx foreign body, using the larynx mirror or endoscopy with in the laryngopharynx for the esophagus foreign bodies, rigid esophagoscopy is better. Key words: Foreign bodies ingestion


Author(s):  
P D Chakravarty ◽  
T Kunanandam ◽  
G Walker

Abstract Background Ingested foreign bodies are a common presentation to paediatric ENT services. Depending on the site, these are usually managed with flexible or rigid oesophagoscopy and retrieval. This paper presents a novel technique for removing a hollow foreign body that could not be removed using conventional means. Method and results After rigid and flexible approaches failed, a guidewire was passed through the foreign body under fluoroscopic guidance and a dilatation balloon passed through the lumen of the object. Inflating the balloon allowed dilatation of the inflamed mucosa above and below the object, facilitating straightforward removal under traction. Conclusion This is a novel and reproducible technique that uses equipment readily available in tertiary referral centres. Employed in this context, the technique enabled removal of an impacted object surrounded by granulation tissue, and would be appropriate for other objects with a lumen.


2021 ◽  
pp. 875647932110332
Author(s):  
Patrick J. Fish

Intraocular foreign bodies (IOFB) present differently depending on the type of material (wood, glass, metal) for the IOFB, extent of the injury, and location of the injury. IOFB and the injury can cause a perforation or penetration of the globe which can require more extensive treatment including surgery. Proper evaluation of the IOFB and injury can help to determine extent of the injury, the prognosis of the vision, and health of the eye before and after treatment but may be difficult for the physician depending on the view of the posterior chamber being compromised by media or simply by patient sensitivity. The extent of the injury may also prevent proper evaluation due to swelling, lacerations on the lids, or pain. Proper ophthalmic sonography can provide a quick evaluation of the globe for any IOFB in both the outpatient setting as well as emergency department setting. Evaluation via sonography may allow the physician to accurately diagnose and properly treat the patient to help restore and prevent further loss of vision.


Author(s):  
Darwin Kaushal ◽  
Amit Goyal ◽  
Kapil Soni ◽  
Bikram Choudhury ◽  
Nithin Prakasan Nair ◽  
...  

Abstract Introduction Airway foreign bodies are emergencies involving multidisciplinary departments like Pediatrics, Aneasthesiology and Otorhinolaryngology. It is always a challenge to diagnose and manage patients who present late to our emergencies. Objective In the present study, we aim to analyze the various challenges faced during the management of tracheobronchial foreign bodies with delayed presentation. Methods A retrospective hospital record-based analysis of patients who presented to us with tracheobronchial foreign bodies from January 2017 to February 2020 was performed. All patients until the age of 16 years old were included in the present study. We assessed the demographics, preoperative, intraoperative and postoperative data of the patients. Results Seventeen patients were analyzed in the study. Among these, 44.4% of the patients had delayed presentation (> 1 month). The majority of the patients had an organic foreign body (Supari or betel nut). All patients underwent rigid bronchoscopy, followed by optical forceps-assisted removal of the foreign body. A total of 82% of the patients had granulations around the foreign body. Conclusion Management of delayed presentation tracheobronchial foreign body is a big challenge for Otorhinolaryngologists. The key factors for preventing complications in the definitive management of tracheobronchial foreign bodies are preoperative planning, multi-discipline teamwork, surgeon expertise and technique.


2019 ◽  
Vol 10 (1) ◽  
Author(s):  
Alessandra D’Amico ◽  
Teresa Perillo ◽  
Lorenzo Ugga ◽  
Renato Cuocolo ◽  
Arturo Brunetti

AbstractIntra-cranial and spinal foreign body reactions represent potential complications of medical procedures. Their diagnosis may be challenging as they frequently show an insidious clinical presentation and can mimic other life-threatening conditions. Their pathophysiological mechanism is represented by a local inflammatory response due to retained or migrated surgical elements. Cranial interventions may be responsible for the presence of retained foreign objects represented by surgical materials (such as sponges, bone wax, and Teflon). Spinal diagnostic and therapeutic procedures, including myelography, chordotomy, vertebroplasty, and device implantation, are another potential source of foreign bodies. These reactions can also follow material migration or embolization, for example in the case of Lipiodol, Teflon, and cement vertebroplasty. Imaging exams, especially CT and MRI, have a central role in the differential diagnosis of these conditions together with patient history. Neuroradiological findings are dependent on the type of material that has been left in or migrated from the surgical area. Knowledge of these entities is relevant for clinical practice as the correct identification of foreign bodies and related inflammatory reactions, material embolisms, or migrations can be difficult. This pictorial review reports neuroradiological semeiotics and differential diagnosis of foreign body-related imaging abnormalities in the brain and spine.


Sign in / Sign up

Export Citation Format

Share Document