Irradiation of Fresh Whole Blood for Prevention of Transfusion-Associated Graft-versus-Host Disease Does Not Impair Platelet Function and Clinical Hemostasis after Open Heart Surgery

Vox Sanguinis ◽  
1995 ◽  
Vol 69 (2) ◽  
pp. 104-109
Author(s):  
J. Lavee ◽  
A. Shinfield ◽  
N. Savion ◽  
M. Thaler ◽  
R. Mohr ◽  
...  
1989 ◽  
Vol 321 (1) ◽  
pp. 25-28 ◽  
Author(s):  
Michael Thaler ◽  
Arie Shamiss ◽  
Shlomit Orgad ◽  
Monica Huszar ◽  
Naomi Nussinovitch ◽  
...  

Blood ◽  
2005 ◽  
Vol 106 (11) ◽  
pp. 2172-2172
Author(s):  
Arthur P. Bode ◽  
Christopher S. Crean ◽  
You-Su Sun ◽  
Wiley Nifong ◽  
Jose L. Boyer ◽  
...  

Abstract Open-heart surgery performed with cardiopulmonary extracorporeal bypass (CPB) of anticoagulated blood often is complicated by excessive postoperative hemorrhage due to an acquired platelet function defect and thrombocytopenia inherent to the procedure. One strategy for reducing excessive blood loss is to protect the platelets pharmacologically from activation and damage during the surgical procedure and the CPB, but most inhibitors of platelet activation used in this way would exacerbate bleeding because of the duration of their effect. INS50589 is a competitive and selective P2Y12 receptor antagonist in development by Inspire Pharmaceuticals Inc. Previous studies in normal dogs indicate that 20μM ADP induced ex vivo whole blood platelet aggregation is completely inhibited by the administration of INS50589 and that the effect is quickly reversed upon discontinuation of the administration. This drug is now being tested for efficacy and safety in a canine model of CPB established at East Carolina University. Subjects in the range of 20–30 kg are prepared by sternotomy for extracorporeal recirculation of blood after systemic heparinization. CPB occurs for ninety minutes, followed by weaning from the pump and maintenance for a four hour postoperative period. INS50589 was administered by continuous infusion at a rate of 17 mg/kg/min at initiation of sternotomy and throughout CPB until weaned. Special testing in all subjects includes ex vivo whole blood aggregometry with two doses of ADP, thromboelastography with the TEG® ADP Mapping kit, bleeding times using a 23 gauge puncture of the exposed jugular vein, and measurements of blood loss from the surgical fields. In the placebo treated group, there was a significant loss of platelet response to ADP during CPB that remained in the post-op period at approx 50% of initial values; in contrast, the drug-treated subjects show post-op recovery of ADP response to within 90% of initial values (p<0.01). The vessel bleeding time (VBT) within both groups was greatly prolonged during CPB. Preliminary analysis suggests that in the post-operative period the VBT returned to baseline values after the infusion was discontinued; however, the return was faster in the INS50589-treated animals when compared with the placebo group. The volume of post-operative blood loss was variable but appears to be less in the drug-treatment group versus placebo controls. When adjusted on the basis of red cell mass in the shed blood per body weight the difference was significant (4.78±1.99e10 vs. 10.1±2.91e10 red blood cells/kg), p <0.05. Other preliminary findings in the treatment group included a lesser CPB-related decrease in platelet count, a higher average hematocrit, higher post-op fibrinogen concentration, and a more stable post-op course. These preliminary findings suggest that INS50589 should be effective in protecting platelet function and reducing blood loss in human patients undergoing open-heart surgery.


1981 ◽  
Author(s):  
S Stenbjerg ◽  
E Berg ◽  
O K Albrechtsen

Heparin levels and ACT were followed during open heart surgery in lo patients. Heparin was assayed by an amidolytic method using substrate S-2222. ACT was determined with an automated method using celite and glass beads as activators of coagulation. Neither the hemodilution nor the depletion of platelets observed during extracorporeal circulation seemed to influence the ACT. An excellent correlation between the ACT and the actual heparin level was found in each patient with coefficients of correlation ranging from 0.73 – 0.97. A slightly better correlation was noticed for values of ACT below 600 seconds. It was concluded that the ACT is a valuable and reliable tool in control of heparinisation during open heart surgery.


1979 ◽  
Vol 25 (1) ◽  
pp. 39-43 ◽  
Author(s):  
H F Osswald ◽  
R Asper ◽  
W Dimai ◽  
W Simon

Abstract We describe a flow-through system with an ion-selective electrode for measurement of blood potassium ion concentration, continuously and on-line off the extracorporeal blood circulation in an operating theater during human open-heart surgery. Comparison measurements were made with the SMA flame photometer (blood plasma) and an Orion SS 30 sodium/potassium analyzer (whole blood). The potassium concentration values obtained with the flow-through system agree well with the ones determined with the flame photometer. The time delay of the measurement with the flow-through system was relatively long (2 min) but delays of only 10--20 s seem feasible. Short time delays can deepen insight and simplify rational treatment under surgery conditions.


CHEST Journal ◽  
1975 ◽  
Vol 68 (3) ◽  
pp. 283-287 ◽  
Author(s):  
Lawrence H. Cohn ◽  
Anna Mae Fosberg ◽  
Warwick P. Anderson ◽  
John J. Collins

Sign in / Sign up

Export Citation Format

Share Document