scholarly journals Endocytoscopy Is Useful for the Diagnosis of Superficial Nonampullary Duodenal Epithelial Tumors

Digestion ◽  
2021 ◽  
pp. 1-8
Author(s):  
Takashi Hirose ◽  
Naomi Kakushima ◽  
Kazuhiro Furukawa ◽  
Satoshi Furune ◽  
Eri Ishikawa ◽  
...  

<b><i>Introduction:</i></b> Endoscopic criteria for the diagnosis of superficial nonampullary duodenal epithelial tumors (SNADETs) are lacking. The aim of this study was to explore the usefulness of endocytoscopy (ECS) in the duodenum. <b><i>Methods:</i></b> A total of 77 ECS images stained by methylene blue and 58 images with double staining of methylene blue and crystal violet were obtained from 20 patients. Images were classified into 3 grades based on nuclear and villi atypia: EC A, B, and C. Diagnostic performance of ECS classification to predict histology and interobserver agreement was evaluated. The performance was compared between staining methods and ×520 or ×936 zoom. <b><i>Results:</i></b> With methylene blue staining, high rates of accuracy, sensitivity, specificity, and positive predictive value (PPV) over 90% were achieved for tumor and nontumor diagnosis as assessed by EC A versus EC B. High rates of accuracy, sensitivity, PPV, and negative predictive value over 90% were achieved for the differentiation between the diagnosis of the Vienna category 3 and 4/5 as assessed by EC B versus C. The accuracy rate of interpreting ECS images with ×936 zoom among 10 endoscopists was 82%, and the interobserver agreement rate was 0.803 (Kendall’s coefficient of concordance). In the ×936 zoom group, methylene blue staining was significantly associated with higher accuracy rate (odds ratio 1.76 [1.06–2.92], <i>p</i> value 0.0297). No benefit was observed by double staining. <b><i>Conclusions:</i></b> ECS diagnosis with methylene blue provides a high accuracy rate and good interobserver agreement to predict histology of SNADETs.

2020 ◽  
Vol 2020 ◽  
pp. 1-5 ◽  
Author(s):  
John Ferguson ◽  
Michal Kazimir ◽  
Michael Gailey ◽  
Frank Moore ◽  
Earl Schott

Introduction. Complicated parapneumonic effusions (CPE) are distinguished from uncomplicated parapneumonic effusions (UPE) by the ability to resolve without drainage. Determinants include pleural pH, pleural glucose, and pleural LDH, along with microbiologic cultures. Inflammation mediated by neutrophil chemotactic cytokines leads to fibrinous loculation of an effusion, and the degree of this inflammation may lead to a CPE. One role of the pathologist is to evaluate for the presence of malignancy in a pleural effusion; however, the ability of the pathologist to distinguish a CPE from UPE has not been evaluated. Materials and Methods. A single-center retrospective study was performed on pleural cytology specimens from 137 patients diagnosed with a parapneumonic effusion or empyema over a five-year interval. Pleural cytology was characterized as either uncomplicated or complicated by two pathologists based on cellular composition and the presence or absence of fibrinous exudate in the fluid. Cohen’s kappa was calculated for interobserver agreement. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of cytologic diagnoses were calculated. Determinants of cytologic accuracy were assessed using Wilcoxon rank sum test, unpaired t-test, and logistic regression. Results. Kappa interobserver agreement between pathologists was 0.753. Pleural fluid cytology sensitivity, specificity, PPV, and NPV for CPE/empyema were 76.0%, 95% CI [65.0, 84.9]; 50%, 95% CI [29.1, 70.9]; 83.3%, 95% CI [76.7, 88.4]; and 38.7%, 95% CI [26.5, 52.5], respectively. The presence of pleural bacteria, elevated pleural LDH, and reduced pleural pH were nonsignificant determinants of cytologic accuracy. Logistic regression was significant for the presence of pleural bacteria (p=0.03) in determining a successful cytologic diagnosis. Conclusion. Pleural cytology adds little value to traditional markers of distinguishing a UPE from CPE. Inflammation on pleural fluid cytology is suggestive of empyema or the presence of pleural fluid bacteria.


PeerJ ◽  
2019 ◽  
Vol 7 ◽  
pp. e6376 ◽  
Author(s):  
Patorn Piromchai ◽  
Thipphailin Juengtrakool ◽  
Supawan Laohasiriwong ◽  
Pornthep Kasemsiri ◽  
Piti Ungarereevittaya

Background Hypocalcemia is a common complication of thyroidectomy resulting from an injury to the parathyroid gland. Methylene blue, which is a medication and dye that has been used for more than a century, is safe and readily available. The previous study has found that methylene blue spray on the surgical field is absorbed by the parathyroid gland faster than in the perithyroidal area. This study was aimed to evaluate the diagnostic value of methylene blue spray to identify the parathyroid gland during thyroid lobectomy. Methods Patients who underwent thyroid lobectomy were recruited. After the recurrent laryngeal nerve was identified, methylene blue was sprayed onto the thyroid bed. After 5 min, the thyroid bed was inspected for areas in which the blue color had been rapidly absorbed. Biopsies were conducted for histopathology at both the stained area and the area in which the color had faded. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Results A total of 47 patients participated in this study. The sensitivity of methylene blue spray to identify the parathyroid gland during thyroid lobectomy was 92.31% (95% CI [63.97–99.81]) and specificity was 56.79% (95% CI [45.31–67.76]). The PPV was 25.53% (95% CI [20.34–31.53]) and NPV was 97.87% (95% CI [87.39–99.67]). There were no patients with post-operative hypocalcemia, allergic reactions to the methylene blue, or methylene blue toxicity. Conclusion The methylene blue spray could serve as a screening tool for identification of the parathyroid gland.


2021 ◽  

Background: This study aimed to evaluate the diagnostic performance of the coronavirus disease 2019 (COVID-19) imaging reporting and data system (CO-RADS) in admitted patients with suspected COVID-19 infection. Methods: This retrospective study included all patients admitted to our hospital with COVID-19 pneumonia suspicion within March 20-May 15, 2020, who were examined by both computed tomography (CT) and real-time reverse transcription polymerase chain reaction (rRT-PCR) at initial presentation. Four radiologists, who were blinded to the rRT-PCR results and medical history, assessed all images independently and classified the CT findings according to the CO-RADS previously defined. Diagnostic value of the scoring system and interobserver agreement in rRT-PCR positive-negative groups and for CO-RADS 1-5 were evaluated. Results: In this study, 274 (153 men and 121 women; 48.8±17.3 years) rRT-PCR positive and 437 (208 men and 229 women; 49.0±19.5 years) rRT-PCR negative individuals were included. It was found that CO-RADS had a good diagnostic performance with area under the receiver operating characteristic roc curve of 0.857. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were obtained at 81.9%, 89.4%, 75.7%, 92.5%, and 84.8%, respectively. The interobserver agreement of four radiologists in CO-RADS 1 and 5 was substantial to almost perfect according to the kappa values. Other CO-RADS scores showed a fair to moderate agreement. The interrater agreement was slightly higher in the PCR (-) patient group than in the positive one. Conclusion: In conclusion, CO-RADS was a successful scoring system for distinguishing highly suspicious cases in terms of COVID-19 infection lung involvement, showing high interobserver agreement.


Author(s):  
Álvaro A. B. FERRAZ ◽  
Fernando SANTA-CRUZ ◽  
João Victor BELFORT ◽  
Vladimir C. T. SÁ ◽  
Luciana T. SIQUEIRA ◽  
...  

ABSTRACT Background: Although considered a safe procedure, sleeve gastrectomy (SG) has a non-negligible risk of major postoperative complications related to it, with special attention to gastric leaks. Aim: Evaluate the clinical value of the methylene blue test (MBT) in predicting the occurrence of post-SG leaks. Methods: Retrospective study that included 1136 patients who underwent SG with intraoperative MBT between 2012 and 2016. Sensitivity, specificity, positive predictive value (PPV) and negative predicted value (NPV) were calculated to determine the clinical correlation between the MBT and the occurrence of postoperative leaks. Staple line oversewing was performed in all patients who presented positive MBT. Results: Laparoscopic SG was performed in 97.0% of cases; open in 2.3%, and robotic in 0.7%. MBT was positive in 19 cases (1.67%). One positive MBT occurred during an open SG and the other 18 at laparoscopy. Moreover, there were nine cases (0.8%) of postoperative leaks, among which, only two presented positive MBT. MBT diagnostic value was evaluated through the calculation of sensitivity (22.0%), specificity (98.0%), PPV (11.0%) and NPV (99.0%). There were no cases of allergic reaction or any other side effect with the use of the methylene blue solution. Conclusion: MBT showed high specificity and negative predictive value, thus presenting an important value to rule out the occurrence of postoperative leaks.


Endoscopy ◽  
2018 ◽  
Vol 50 (08) ◽  
pp. 779-789 ◽  
Author(s):  
Marietta Iacucci ◽  
Cristina Trovato ◽  
Marco Daperno ◽  
Oluseyi Akinola ◽  
David Greenwald ◽  
...  

Abstract Background Prediction of histology of small polyps facilitates colonoscopic treatment. The aims of this study were: 1) to develop a simplified polyp classification, 2) to evaluate its performance in predicting polyp histology, and 3) to evaluate the reproducibility of the classification by trainees using multiplatform endoscopic systems. Methods In phase 1, a new simplified endoscopic classification for polyps – Simplified Identification Method for Polyp Labeling during Endoscopy (SIMPLE) – was created, using the new I-SCAN OE system (Pentax, Tokyo, Japan), by eight international experts. In phase 2, the accuracy, level of confidence, and interobserver agreement to predict polyp histology before and after training, and univariable/multivariable analysis of the endoscopic features, were performed. In phase 3, the reproducibility of SIMPLE by trainees using different endoscopy platforms was evaluated. Results Using the SIMPLE classification, the accuracy of experts in predicting polyps was 83 % (95 % confidence interval [CI] 77 % – 88 %) before and 94 % (95 %CI 89 % – 97 %) after training (P  = 0.002). The sensitivity, specificity, positive predictive value, and negative predictive value after training were 97 %, 88 %, 95 %, and 91 %. The interobserver agreement of polyp diagnosis improved from 0.46 (95 %CI 0.30 – 0.64) before to 0.66 (95 %CI 0.48 – 0.82) after training. The trainees demonstrated that the SIMPLE classification is applicable across endoscopy platforms, with similar post-training accuracies for narrow-band imaging NBI classification (0.69; 95 %CI 0.64 – 0.73) and SIMPLE (0.71; 95 %CI 0.67 – 0.75). Conclusions Using the I-SCAN OE system, the new SIMPLE classification demonstrated a high degree of accuracy for adenoma diagnosis, meeting the ASGE PIVI recommendations. We demonstrated that SIMPLE may be used with either I-SCAN OE or NBI.


2013 ◽  
Vol 168 (5) ◽  
pp. 649-655 ◽  
Author(s):  
Gilles Russ ◽  
Bénédicte Royer ◽  
Claude Bigorgne ◽  
Agnès Rouxel ◽  
Marie Bienvenu-Perrard ◽  
...  

ObjectiveTo evaluate prospectively the diagnostic accuracy of the thyroid imaging reporting and data system (TI-RADS) and its interobserver agreement and to estimate the reduction of indications of fine-needle aspiration biopsies (FNABs).DesignA prospective comparative study was designed.MethodsIn 2 years, 4550 nodules in 3543 patients were prospectively scored using a flowchart and a six-point scale and then submitted to US-FNAB. Results were read according to the Bethesda system. Histopathological results were available for 263 cases after surgery. Sensitivity, specificity, negative predictive value (NPV) and positive predictive value, and accuracy were calculated for the gray-scale score, elastography, and a combination of both methods. Interobserver agreement was calculated using the kappa statistic. The reduction in the number of FNABs was estimated.ResultsWhen compared with cytopathological results, sensitivity, specificity, NPV, and accuracy were 95.7, 61, 99.7, and 62% for the TI-RADS gray-scale score; 74.2, 91.1, 98, and 90% for elastography; and 98.5, 44.7, 99.8, and 48.3% for a combination of both methods respectively. When compared with histopathological results, the sensitivity of the gray-scale score, elastography, and a combination of both methods were 93.2, 41.9, and 96.7% respectively. Interobserver agreement for the six-point scale and the recommendation for biopsy were substantial (κ value=0.72 and 0.76 respectively). The reduction in the number of FNABs was estimated to be 33.8%.ConclusionThe TI-RADS score has high sensitivity and NPV for the diagnosis of thyroid carcinoma. A hard nodule should always be considered as suspicious for malignancy but elastography cannot be used alone. Combination of elastography with gray-scale can be used to improve sensitivity or specificity. Interobserver agreement and decrease in unnecessary biopsies are significant.


2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


2018 ◽  
Vol 1 ◽  
pp. 9
Author(s):  
Harshad Arvind Vanjare ◽  
Jyoti Panwar

Objective The objective of the study was to assess the accuracy of ultrasound examination for the diagnosis of rotator cuff tear and tendinosis performed by a short experienced operator, compared to magnetic resonance imaging (MRI) results. Method A total of 70 subjects suspected to have rotator cuff tear or tendinosis and planned for shoulder MRI were included in the study. Shoulder ultrasound was performed either before or after the MRI scan on the same day. Ultrasound operator had a short experience in performing an ultrasound of the shoulder. Ultrasound findings were correlated to MRI findings. Results Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for the diagnosis of tendinosis were 58%, 84%, 63%, 80%, and 75%, respectively, and it was 68%, 91%, 73%, 88%, and 85%, respectively, for the diagnosis of rotator cuff tear. Conclusions Sensitivity for diagnosing rotator cuff tear or tendinosis was moderate but had a higher negative predictive value. Thus, the ultrasound operator with a short experience in performing shoulder ultrasound had moderate sensitivity in diagnosing tendinosis or tears; however, could exclude them with confidence.


2017 ◽  
pp. 59-63
Author(s):  
Thanh Hung Dieu ◽  
Anh Vu Nguyen

Objects: We assessed the ability of ST-segment elevation in lead aVR to predict left main and/or 3-vessel disease (LM/3VD) in patients with acute coronary syndromes (ACS). Meterial and Method: 410 patients with ACS, who underwent coronary angiography, were evaluated. Results: 131 (31.9%) patients have been LM/3VD. ST segment elevation > 0.05 mV in leads aVR have been an independent predictor LM/3VD with sensitivity, specificity, positive predictive value PPV) and negative predictive value (NPV) 74.0%, 78.1%, 61.4% and 86.5%, respectively (p<0.001). ST segment elevation > 0.05 mV in leads aVR with ST segment depression in leads V4-V6 have related LM/3VD with sensitivity, specificity, PPV and NPV 44.3%, 92.8%, 74.4% and 75.2%, respectively (p<0.001). ST segment elevation > 0.1 mV in leads aVR have related LM/3VD with sensitivity, specificity, PPV and NPV 51.9%, 87.1%, 65.1% and 79.4%, respectively (p<0.001). Conclusions: ST segment elevation > 0.05 mV in leads aVR have been an independent predictor LM/3VD in patients with ACS. Key words: Acute coronary syndromes, ST-segment elevation, aVR


Sign in / Sign up

Export Citation Format

Share Document