scholarly journals Fault analysis in power system using power systems computer aided design

Author(s):  
Fortune Chukwuebuka Amanze ◽  
Amanze Destiny Josiah

<span>This work presents a fault analysis simulation model of an IEEE 30 bus system in a distribution network. This work annalysed the effect of fault current and fault voltage in a distribution system. A circuit breaker was introduced into the system to neutralize the effect of the fault. The system was run on a PSCAD software and results were obtained. The system was monitored based on the start time and the end time of the fault and how well the circuit breaker reacts with those times. Fault occurred from 0.100 to 0.300 seconds before it was removed. At the time fault was not applied (i.e. from 0.00 to 0.100 and from 0.300 to 0.72), the circuit breaker was close and became open when fault was applied so as to cut off current flow through the line.The result obtained gave the disruption caused by the fault and the quick response of the circuit breaker in neutralizing it. Results gotten are based on when the circuit breaker is close and no fault is applied and when the circuit breaker is open due to fault. From this work, it was obtained that circuit breakers are very essential in system protection and reliability.</span>

Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4383
Author(s):  
Jun He ◽  
Ke Wang ◽  
Jiangang Li

Pyro-breaker, a fast-responding, highly reliable and explosive-driven circuit breaker, is utilized in several Quench Protection Systems (QPS). The commutation process and its parameters are the main technical considerations in the process of designing a new pyro-breaker. The commutation parameters, such as the commutation time and the current change rate, are not only determined by the electrical parameters of the commutation circuit but also the arc behavior during the operation. The arc behavior is greatly affected by the structure and the driving mechanism of the Commutation Section (CS) in the pyro-breaker. The arc model was developed decades ago and the black-box arc model is considered a valid method to study arc behavior. In this paper, the Schavemaker black-box arc model, an improved Mayr-type arc model, is applied to study the commutation process of a newly designed pyro-breaker. Unlike normal circuit breakers, the arc discussed in this paper is discharged in deionized water. A parameter selection method is proposed. The practicability of the method is verified by numerical calculation in Power Systems Computer Aided Design (PSCAD) and experimentally.


Author(s):  
Rohit Bhat ◽  
Akshay Deshpande ◽  
Rahul Rai ◽  
Ehsan Tarkesh Esfahani

The aim of this paper is to explore a new multimodal Computer Aided Design (CAD) platform based on brain-computer interfaces and touch based systems. The paper describes experiments and algorithms for manipulating geometrical objects in CAD systems using touch-based gestures and movement imagery detected though brain waves. Gestures associated with touch based systems are subjected to ambiguity since they are two dimensional in nature. Brain signals are considered here as the main source to resolve these ambiguities. The brainwaves are recorded in terms of electroencephalogram (EEG) signals. Users wear a neuroheadset and try to move and rotate a target object on a touch screen. As they perform these actions, the EEG headset collects brain activity from 14 locations on the scalp. The data is analyzed in the time-frequency domain to detect the desynchronizations of certain frequency bands (3–7Hz, 8–13 Hz, 14–20Hz 21–29Hz and 30–50Hz) in the temporal cortex as an indication of motor imagery.


1979 ◽  
Vol 23 (1) ◽  
pp. 55-58 ◽  
Author(s):  
James L. Lewis

The Operator Station Design System is resident in NASA's Johnson Space Center Spacecraft Design Division Design Performance Laboratory. It includes stand-alone mini-computer hardware and Panel Layout Automated Interactive Design and Crew Station Assessment of Reach software. The data base consists of the Shuttle Transportation System Orbiter Crew Compartment (in part), the Orbiter payload bay and remote manipulator (in part), and various anthropometric populations. The system is utilized to provide panel layouts, assess reach and vision, determine interference and fit problems early in the design phase, study design applications as a function of anthropometric and mission requirements, and to accomplish conceptual design to support advanced study efforts.


1994 ◽  
Vol 10 (04) ◽  
pp. 217-222
Author(s):  
Kohji Honda ◽  
Noriyuki Tabushi

A VLCC (very large crude oil carrier) has approximately 1000 curved longitudinal beams, many of which have three-dimensional complicated curvatures. Due to the shortage of highly skilled workers and the need to keep costs down, production and structural designers have worked to reduce the number of such beams. In order to meet the requirements of production, the authors' company has attempted several design approaches for the longitudinal beam layout to reduce the number of beams that have complicated curvature. Recently, through the application of a computer-aided design system, which has been improved for shipbuilding based on the Calma's system, a new design method for the longitudinal beam layout has been successfully developed. A significant number of beams with a twisted configuration have been eliminated and replaced with beams of simpler, two-dimensional shapes. This paper shows the transition of these design approaches, and the application of the new design to building a VLCC.


2020 ◽  
Vol 1 (3) ◽  
pp. 8-16
Author(s):  
Oshin Ola Austin ◽  
Oluwasanmi Alonge ◽  
Ajayi Joseph Adeniyi

In any power systems, protective devices will detect fault conditions and operate circuit breakers in order to disconnect the load from the fault current and limit loss of service due to failure. This fault may involve one or more phases and the ground, or may occur between two or more phases in a three-phase systems. In ground, fault’ or ‘earth fault, current flows into the earth. In a poly-phase system, a fault may affect each of the three phases equally which is a symmetrical fault. If only some phases are affected, the resulting ‘asymmetrical fault’ becomes more complicated to analyze due to the simplifying assumption of equal current magnitude in all the phases being no longer applicable. Therefore, the prospective short circuit current of the fault can be calculated for power systems analysis procedures. This will assist in the choice of protective devices like circuit breakers, current transformers and relays. This research work evaluated and analyzed the occurrence of faults in a distribution system. Fault currents were obtained and the maximum tripping time required for the protective devices to operate were determined. Hence, it was possible to select appropriate relay and circuit breaker for effective operation of a distribution


2020 ◽  
Author(s):  
Samir Ibrahim Abood ◽  
Dr. Muna Hamid Fayyadh

Sign in / Sign up

Export Citation Format

Share Document