scholarly journals Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair

Author(s):  
Elixène Jean-Baptiste ◽  
Patrick Feugier ◽  
Coralie Cruzel ◽  
Gabrielle Sarlon-Bartoli ◽  
Thierry Reix ◽  
...  

Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-related morphological abnormality requiring reintervention or an amendment to the follow-up policy was revealed by CTA. Database was locked on October 2, 2017. Our main outcome measures were sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratios of DUS against reference standard CTA. CIs are binomial 95% CI. Results This study recruited prospectively 659 post-EVAR patients of whom 539 (82%) were eligible for further analysis. Following the baseline inclusion visit, 940 additional follow-up visits were performed in the 539 patients. Major aneurysm-related morphological abnormalities were revealed by CTA in 103 patients (17.2/100 person-years [95% CI, 13.9–20.5]). DUS accurately identified 40 patients where a major aneurysm-related morphological abnormality was present (sensitivity, 39% [95% CI, 29–48]) and 403 of 436 patients with negative CTA (specificity, 92% [95% CI, 90–95]). The negative predictive value and positive predictive value of DUS were 92% (95% CI, 90–95) and 39% (95% CI, 27–50), respectively. The positive likelihood ratio was 4.87 (95% CI, 2.9–9.6). DUS sensitivity reached 73% (95% CI, 51–96) in patients requiring an effective reintervention. Conclusions DUS had an overall low sensitivity in the follow-up of patients after EVAR, but its performance improved meaningfully when the subset of patients requiring effective reinterventions was considered. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01230203.

2016 ◽  
Vol 76 (1) ◽  
pp. 119-125 ◽  
Author(s):  
Aase Haj Hensvold ◽  
Thomas Frisell ◽  
Patrik K E Magnusson ◽  
Rikard Holmdahl ◽  
Johan Askling ◽  
...  

ObjectiveAnti-citrullinated protein antibodies (ACPA) are highly specific for rheumatoid arthritis (RA), but the diagnostic accuracy of ACPA in the general population has not been thoroughly assessed. We aimed to assess the diagnostic accuracy of ACPA for RA in the general population and to further characterise the citrullinated peptide recognition pattern.MethodsSerum samples from a large population-representative twin cohort consisting of 12 590 individuals were analysed for the presence of ACPA using anti-CCP2 ELISA. All ACPA-positive samples were further tested on ELISAs for four peptide-specific ACPA. RA cases were identified by linkage to the Swedish National Patient Register at inclusion and after a median follow-up of 37 months (IQR 31–49).Results350 out of 12 590 individuals had a positive anti-CCP2 test, measuring ACPA. Of these, 103 had an RA diagnosis at the time of blood donation and inclusion. During a median follow-up of 3 years, an additional 21 of the remaining 247 ACPA-positive individuals developed RA. Overall, a positive anti-CCP2 test had a positive predictive value of 29% for prevalent RA at inclusion (negative predictive value of 99.6%). High titres (>3× cut-off) of anti-CCP2 increased the positive predictive value to 48% (negative predictive value of 99.5%). ACPA-positive individuals without RA had lower anti-CCP2 titres and fewer peptide-specific ACPA than ACPA-positive patients with RA and higher C reactive protein levels than ACPA-negative individuals without RA.ConclusionPresence of ACPA and especially high titres of anti-CCP2 have a high diagnostic accuracy for an RA diagnosis in a population setting.


2021 ◽  
Vol 15 (11) ◽  
pp. 3164-3165
Author(s):  
Mohammad Iltaf ◽  
Sana Akhtar ◽  
Dilaram Khan

Objective: To establish the diagnostic accuracy of BISAP in detecting the severe acute pancreatitis keeping computed tomography severity index as gold standard. Study Design: Cross-sectional study Place and Duration of Study: Department of Gastroenterology, Hayatabad Medical Complex, Peshawar from April 16th 2018 to 16th October 2018. Methodology: One hundred and twenty nine patients of age range of 18-60, of either gender having severe acute pancreatitis were included. While patients already diagnosed as severe acute pancreatitis and having known history of chronic pancreatitis were excluded. Patients were subjected to CT scan to confirm whether the severe acute pancreatitis is present or not. All CT scans were reported by single experiences radiologist. Results: There were 30.3% were males and 69.7% were females with mean age 42±11.03 years. BISAP had sensitivity 92.74%, specificity 80%, positive predictive value 99.13%, negative predictive value 20.76% and the overall diagnostic accuracy was 92.24%. Conclusion: BISAP had sensitivity 93.61%, specificity 100%, positive predictive value 100%, negative predictive value 40% and the overall diagnostic accuracy was 93.87% in severe acute pancreatitis keeping CT severity index as gold standard. Keywords: Accuracy, Severe acute pancreatitis, Computed tomography


2020 ◽  
Vol 7 (47) ◽  
pp. 2762-2766
Author(s):  
N. Imdad Ali ◽  
Noor Elahi Pasha ◽  
Ravishankar T.H.S

BACKGROUND Imaging plays a major role in the diagnosis and management of patients with urolithiasis. Non-Contrast Computed Tomography (NCCT) is generally accepted as the gold standard, but there are concerns over higher radiation exposure from NCCT to the patient population. Our prospective study compared the diagnostic accuracy of plain X-ray KUB (Kidney, Ureter, Bladder) and USG (Ultrasonography) with NCCT in the evaluation of patients with ureteric colic. METHODS This study conducted from December 2018 to January 2020 in the Department of Urology, Vijayanagar Institute of Medical Sciences, and attached Hospital. 230 patients with ureteric colic were evaluated for ureteric calculi with x-ray KUB, USG (Ultrasonography) abdomen and pelvis and NCCT (Non-Contrast Computed Tomography) KUB region. RESULTS Out of 230 patients, 168 (73 %) were males and 62 (26.9 %) were females. Ages of the study population ranged from 18 to 55 yrs. 198 of the 230 patients were confirmed to have ureteric calculus, with lower ureteric calculus 97 (48.9 %), upper ureteric 65 (32.8 %), middle ureteric 29 (14.6 %), and multiple 7 (3.5 %). X-ray and USG (Ultrasonography) group yielded a sensitivity of 86.3 %, a specificity of 87.5 %, positive predictive value 97 %, and negative predictive value 51 %. While On NCCT (Non-Contrast Computed Tomography), a total of 192 patients (96 %) demonstrated ureterolithiasis of the 198 patients confirmed to have ureteric calculi (Table 2). X-ray and USG group yielded a sensitivity of 96.9 %, specificity of 93.6 %, positive predictive value 98.9 %, and negative predictive value 83 %. CONCLUSIONS Combination of x-ray KUB and USG, and NCCT were found to be excellent imaging modalities for the detection of ureteric calculi. X-ray KUB and USG can be used as the first investigation of choice for patients with ureteric colic and for follow up of patients after treatment. KEYWORDS Ureteric Colic, Ureterolithiasis, Ultrasonography


Author(s):  
Robert Soumay Houmsou ◽  
Binga Emmanuel Wama ◽  
Hemen Agere ◽  
John Ador Uniga ◽  
Timothy Jerry Jerry ◽  
...  

Abstract Objectives Schistosomiasis is a blood fluke parasitic illness affecting human lives in rural endemic areas. This study evaluated the performance of Schistosoma ICT Ig G - IgM for screening urinary schistosomiasis in Nigeria. Methods Three hundred and seventy four (374) urine samples were examined. Reagent strips, urine filtration and Schistosoma ICT Ig G - IgM were used for analysis. Schistosoma ICT Ig G - IgM used 2 mL of each serum for serological examination. Then, 3 mL of each preserved serum was sent to LDBIO Diagnostics, France for re-examination with Schistosoma ICT IgG-IgM and confirmation with SCHISTO Western blot (WB) IgG. The performance of the index tests was determined using sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and positive likelihood ratio (PLR). The Youden index (YI) and diagnostic accuracy (DA) were used to determine the accuracy of each test. The statistical significance was at p-value ≤0.05. Results The test had a sensitivity of 94.9%, specificity of 63.9%, positive predictive value of 72.4%, negative predictive value of 92.6%, and positive likelihood ratio of 2.62. Schistosoma ICT Ig G - IgM had a good Cohen’s kappa index (κ=0.68), good Youden index (YI=0.58) and good diagnostic accuracy (DA=0.78). Conclusions Schistosoma ICT Ig G - IgM has proven to be the best technique for the screening of urinary schistosomiasis in Nigeria.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Moshage ◽  
S Smolka ◽  
S Achenbach ◽  
F Ammon ◽  
P Ferstl ◽  
...  

Abstract Background The accuracy of CT-derived FFR (FFRCT) has been repeatedly reported. However, the influence of lesion location on accuracy is unknown. Therefore, we evaluated the diagnostic accuracy of FFRCT to detect lesion-specific ischemia and determined the influence of lesion location (proximal vs. distal vessel segments) compared to invasively measured FFR in patients with suspected CAD. Methods A total of 136 vessels in which “Dual-Source”-CT coronary angiography had been performed due to suspected CAD and who were further referred for invasive coronary angiography with invasive FFR measurement within three months of the index CT examination were retrospectively identified and screened for inclusion in this analysis. Patients with either left main coronary artery stenoses, bifurcation or ostial stenoses were excluded. Invasive FFR was measured using a pressure wire (CERTUS®, St. Jude Medical, Minnesota, USA or Verrata®, Volcano, San Diego, USA). FFRCT was calculated using an on-site prototype (cFFR Version 3.0, Siemens Healthineers, Forchheim, Germany). All vessels were analyzed by an experienced observer blinded to the results of invasive FFR. Stenoses with invasively measured FFR ≤0.80 were classified as hemodynamically significant. We evaluated the diagnostic accuracy of FFRCT in proximal vs. non-proximal vessel segments. Proximal lesions included stenoses located in segment one, six, eleven and twelve. All other stenoses were categorized as distal lesions. Results Out of 136 coronary stenoses, 47 (35%) were located in proximal segments and 89 (65%) lesions were located in distal segments. Compared to invasive FFR, the sensitivity of FFRCT to correctly identify/exclude hemodynamically significant stenoses in proximal vessel segments was 93% (95% CI: 68–99.8%) and the specificity was 100% (95% CI: 89–100%), compared to a sensitivity of 72% (95% CI: 46.5–90%) and a specificity of 87% (95% CI: 77–94%) for FFRCT in distal lesions. The positive predictive value was 100% and the negative predictive value was 97% (95% CI: 82.8–99.5%) compared to a positive predictive value of 59% (95% CI: 42–93.9%) and a negative predictive value of 93% (95% CI: 85.4–96.3%) for proximal vs. distal vessel segment, respectively. This corresponds to an accuracy of 98% vs. 84%, respectively (p=0.02). ROC-Curve analysis showed a slightly higher – albeit non-significant – area under the curve for FFRCT to detect hemodynamic relevance in proximal lesions compared to distal lesions (AUC 0.95, p<0.001 vs. AUC: 0.86, p<0.001, respectively, p=0.2). Conclusion FFRCT obtained using an on-site prototype shows overall a high diagnostic accuracy for detecting lesions causing ischemia as compared to invasive FFR with a trend towards better diagnostic performance in proximal vessel segments. Funding Acknowledgement Type of funding source: None


2021 ◽  
Vol 10 (1) ◽  
pp. 20-25
Author(s):  
Sujan Shrestha ◽  
Mamen Prasad Gorhaly ◽  
Manil Ratna Bajracharya

Background Diabetic peripheral neuropathy (DPN) is a significant independent risk factor for diabetic foot, and an effective screening instrument is required to diagnose DPN early to prevent future ulceration and amputation. This study aims to determine the diagnostic accuracy of monofilament test to detect diabetic peripheral neuropathy. Methods This cross-sectional study was conducted in National Academy of Medical Sciences, Bir hospital, Mahabouddha, Kathmandu from February 2016 to January 2017. A total of 96 diabetic patients attending inpatient and outpatient Department were selected. Diabetic peripheral neuropathy was assessed by measurement of loss of protective sensation (LOPS) by monofilament test and compared with vibration perception threshold by standard biothesiometer. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were calculated. Results The prevalence of diabetic peripheral neuropathy was 26%. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were found to be 92.0%, 95.8%, 88.5% and 97.1% respectively. There was strong association between LOPS by monofilament and vibration perception threshold by biothesiometer. Conclusion This study showed a strong diagnostic accuracy of monofilament test to detect DPN when compared with biothesiometer. As monofilament test is a cheap, easily available, and portable, it can be used in the periphery where biothesiometer is not available.  


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Tahir Iqbal ◽  
Muhammad Usman Shahid ◽  
Ishfaq Ahmad Shad ◽  
Shahzad Karim Bhatti ◽  
Syed Amir Gilani ◽  
...  

ABSTRACT: BACKGROUND: A common surgical emergency is acute appendicitis. Various diagnostic tools are available to diagnosis acute appendicitis. Radiological investigations play an important role in making accurate and early diagnosis and thus preventing morbidity associated with the disease. OBJECTIVE: To determine the diagnostic accuracy of gray scale ultrasonography versus color Doppler in suspected cases of acute appendicitis. MATERIALS AND METHODS: The study was carried in the department of Radiology of Mayo Hospital, Lahore. A total of 75 patients were enrolled of age 18-40 years, both genders who were suspected cases of acute appendicitis. All patients underwent baseline investigations along with gray scale ultrasonography and color Doppler. All patients were subjected to surgery to confirm the diagnosis and findings were subjected to statistical analysis. RESULTS: The mean age of the patients was 23.25 ±10.55 and mean transverse diameter of appendix was 8.37 ±3.39. There were 62.7% males and 37.3%females. Findings of gray scale ultrasonography and color Doppler were then correlated with surgical findings to calculate the diagnostic accuracy of these modalities. The results revealed that gray scale ultrasonography sensitivity, specificity, positive predictive value, negative predictive value and accuracy was 92.7%, 94.32%, 95%, 91.4% and 93.3% respectively, whereas color Doppler had sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 97.7%, 93.9%, 95.3%, 97% and 96% respectively. Diagnostic accuracy of both modalities together was 98.6%. CONCLUSION: Color Doppler has better diagnostic accuracy than gray scale ultrasonography for diagnosis of acute appendicitis and the combination of both modalities yields diagnostic accuracy that is similar to gold standard.


Stroke ◽  
2020 ◽  
Vol 51 (12) ◽  
pp. 3765-3769
Author(s):  
Charles Esenwa ◽  
Ji-Ae Lee ◽  
Taha Nisar ◽  
Anna Shmukler ◽  
Inessa Goldman ◽  
...  

Background and Purpose: Evaluation of the lung apices using computed tomography angiography of the head and neck during acute ischemic stroke (AIS) can provide the first objective opportunity to screen for coronavirus disease 2019 (COVID-19). Methods: We performed an analysis assessing the utility of apical lung exam on computed tomography angiography for COVID-19–specific lung findings in 57 patients presenting with AIS. We measured the diagnostic accuracy of apical lung assessment alone and in combination with patient-reported symptoms and incorporate both to propose a COVID-19 era AIS algorithm. Results: Apical lung assessment when used in isolation, yielded a sensitivity of 0.67, specificity of 0.93, positive predictive value of 0.19, negative predictive value of 0.99, and accuracy of 0.92 for the diagnosis of COVID-19, in patients presenting to the hospital for AIS. When combined with self-reported clinical symptoms of cough or shortness of breath, sensitivity of apical lung assessment improved to 0.83. Conclusions: Apical lung assessment on computed tomography angiography is an accurate screening tool for COVID-19 and can serve as part of a combined screening approach in AIS.


2020 ◽  
pp. 028418512096389
Author(s):  
Matteo Renzulli ◽  
Alfredo Clemente ◽  
Stefano Brocchi ◽  
Chiara Gelati ◽  
Simone Zanotti ◽  
...  

Background Deep inferior epigastric perforator (DIEP) flap reconstruction is the gold standard reconstructive technique for women undergoing breast cancer surgery. A preoperative computed tomography angiography (CTA)-dedicated protocol and 3D reconstructions are mandatory for correct surgical planning. Purpose To evaluate the diagnostic performance of a new preoperative CTA protocol and a new reconstruction method in the assessment of DIEP technique. Material and Methods A total of 263 women (median age 49 years, age range 26–73 years) underwent preoperative CTA examination before DIEP flap breast reconstruction. A CTA-dedicated protocol followed by 3D-reconstructions were performed. Identification, branching pattern, and caliber at origin were assessed for each perforator. Intraoperative findings were the standard of reference. The sensitivity, positive predictive value, and diagnostic accuracy of the preoperative CTA protocol were calculated. Results In 255/263 (97%) patients, the dominant perforators assessed by CTA resulted adequate for surgical reconstruction. In 260/263 (99%) cases, the imaging localization of the dominant perforators corresponded with those seen intraoperatively (mean errors ≤1 cm). The preoperative CTA imaging sensitivity, positive predictive value, and diagnostic accuracy in determining the localization of perforators were 99% (95% CI 98–100), 100% and 99% (95% CI 98–100), respectively. No statistically significant differences were found between the CTA findings and the surgical findings for the assessment of branching pattern and caliber of the dominant perforators ( P < 0.001). Conclusion The present protocol has demonstrated high accuracy in the CTA imaging assessment of the perforators before DIEP flap reconstruction with high reproducibility between CT and surgical findings.


Sign in / Sign up

Export Citation Format

Share Document