Influence of lesion location on the accuracy of CT derived FFR: head-to-head comparison with invasive FFR

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Moshage ◽  
S Smolka ◽  
S Achenbach ◽  
F Ammon ◽  
P Ferstl ◽  
...  

Abstract Background The accuracy of CT-derived FFR (FFRCT) has been repeatedly reported. However, the influence of lesion location on accuracy is unknown. Therefore, we evaluated the diagnostic accuracy of FFRCT to detect lesion-specific ischemia and determined the influence of lesion location (proximal vs. distal vessel segments) compared to invasively measured FFR in patients with suspected CAD. Methods A total of 136 vessels in which “Dual-Source”-CT coronary angiography had been performed due to suspected CAD and who were further referred for invasive coronary angiography with invasive FFR measurement within three months of the index CT examination were retrospectively identified and screened for inclusion in this analysis. Patients with either left main coronary artery stenoses, bifurcation or ostial stenoses were excluded. Invasive FFR was measured using a pressure wire (CERTUS®, St. Jude Medical, Minnesota, USA or Verrata®, Volcano, San Diego, USA). FFRCT was calculated using an on-site prototype (cFFR Version 3.0, Siemens Healthineers, Forchheim, Germany). All vessels were analyzed by an experienced observer blinded to the results of invasive FFR. Stenoses with invasively measured FFR ≤0.80 were classified as hemodynamically significant. We evaluated the diagnostic accuracy of FFRCT in proximal vs. non-proximal vessel segments. Proximal lesions included stenoses located in segment one, six, eleven and twelve. All other stenoses were categorized as distal lesions. Results Out of 136 coronary stenoses, 47 (35%) were located in proximal segments and 89 (65%) lesions were located in distal segments. Compared to invasive FFR, the sensitivity of FFRCT to correctly identify/exclude hemodynamically significant stenoses in proximal vessel segments was 93% (95% CI: 68–99.8%) and the specificity was 100% (95% CI: 89–100%), compared to a sensitivity of 72% (95% CI: 46.5–90%) and a specificity of 87% (95% CI: 77–94%) for FFRCT in distal lesions. The positive predictive value was 100% and the negative predictive value was 97% (95% CI: 82.8–99.5%) compared to a positive predictive value of 59% (95% CI: 42–93.9%) and a negative predictive value of 93% (95% CI: 85.4–96.3%) for proximal vs. distal vessel segment, respectively. This corresponds to an accuracy of 98% vs. 84%, respectively (p=0.02). ROC-Curve analysis showed a slightly higher – albeit non-significant – area under the curve for FFRCT to detect hemodynamic relevance in proximal lesions compared to distal lesions (AUC 0.95, p<0.001 vs. AUC: 0.86, p<0.001, respectively, p=0.2). Conclusion FFRCT obtained using an on-site prototype shows overall a high diagnostic accuracy for detecting lesions causing ischemia as compared to invasive FFR with a trend towards better diagnostic performance in proximal vessel segments. Funding Acknowledgement Type of funding source: None

2010 ◽  
Vol 4 ◽  
pp. CMC.S3864 ◽  
Author(s):  
M. Wehrschuetz ◽  
E. Wehrschuetz ◽  
H. Schuchlenz ◽  
G. Schaffler

Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subsequent introduction of 64-slice scanners promised excellent and fast results for coronary artery studies. This prompted us to evaluate the diagnostic accuracy, sensitivity, specificity, and the negative und positive predictive value of 64-slice MSCT in the detection of haemodynamically significant coronary artery stenoses. Thirty-seven consecutive subjects with suspected coronary artery disease were evaluated with MSCT angiography and the results compared with QCA. All vessels were considered for the assessment of significant coronary artery stenosis (diameter reduction ≥ 50%). Thirteen patients (35%) were identified as having significant coronary artery stenoses on QCA with 6.3% (35/555) affected segments. None of the coronary segments were excluded from analysis. Overall sensitivity for classifying stenoses of 64-slice MSCT was 69%, specificity was 92%, positive predictive value was 38% and negative predictive value was 98%. The interobserver variability for detection of significant lesions had a κ-value of 0.43. Sixty-four-slice MSCT offers the diagnostic potential to detect coronary artery disease, to quantify haemodynamically significant coronary artery stenoses and to avoid unnecessary invasive coronary artery examinations.


2021 ◽  
Vol 10 (1) ◽  
pp. 20-25
Author(s):  
Sujan Shrestha ◽  
Mamen Prasad Gorhaly ◽  
Manil Ratna Bajracharya

Background Diabetic peripheral neuropathy (DPN) is a significant independent risk factor for diabetic foot, and an effective screening instrument is required to diagnose DPN early to prevent future ulceration and amputation. This study aims to determine the diagnostic accuracy of monofilament test to detect diabetic peripheral neuropathy. Methods This cross-sectional study was conducted in National Academy of Medical Sciences, Bir hospital, Mahabouddha, Kathmandu from February 2016 to January 2017. A total of 96 diabetic patients attending inpatient and outpatient Department were selected. Diabetic peripheral neuropathy was assessed by measurement of loss of protective sensation (LOPS) by monofilament test and compared with vibration perception threshold by standard biothesiometer. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were calculated. Results The prevalence of diabetic peripheral neuropathy was 26%. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were found to be 92.0%, 95.8%, 88.5% and 97.1% respectively. There was strong association between LOPS by monofilament and vibration perception threshold by biothesiometer. Conclusion This study showed a strong diagnostic accuracy of monofilament test to detect DPN when compared with biothesiometer. As monofilament test is a cheap, easily available, and portable, it can be used in the periphery where biothesiometer is not available.  


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Tahir Iqbal ◽  
Muhammad Usman Shahid ◽  
Ishfaq Ahmad Shad ◽  
Shahzad Karim Bhatti ◽  
Syed Amir Gilani ◽  
...  

ABSTRACT: BACKGROUND: A common surgical emergency is acute appendicitis. Various diagnostic tools are available to diagnosis acute appendicitis. Radiological investigations play an important role in making accurate and early diagnosis and thus preventing morbidity associated with the disease. OBJECTIVE: To determine the diagnostic accuracy of gray scale ultrasonography versus color Doppler in suspected cases of acute appendicitis. MATERIALS AND METHODS: The study was carried in the department of Radiology of Mayo Hospital, Lahore. A total of 75 patients were enrolled of age 18-40 years, both genders who were suspected cases of acute appendicitis. All patients underwent baseline investigations along with gray scale ultrasonography and color Doppler. All patients were subjected to surgery to confirm the diagnosis and findings were subjected to statistical analysis. RESULTS: The mean age of the patients was 23.25 ±10.55 and mean transverse diameter of appendix was 8.37 ±3.39. There were 62.7% males and 37.3%females. Findings of gray scale ultrasonography and color Doppler were then correlated with surgical findings to calculate the diagnostic accuracy of these modalities. The results revealed that gray scale ultrasonography sensitivity, specificity, positive predictive value, negative predictive value and accuracy was 92.7%, 94.32%, 95%, 91.4% and 93.3% respectively, whereas color Doppler had sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 97.7%, 93.9%, 95.3%, 97% and 96% respectively. Diagnostic accuracy of both modalities together was 98.6%. CONCLUSION: Color Doppler has better diagnostic accuracy than gray scale ultrasonography for diagnosis of acute appendicitis and the combination of both modalities yields diagnostic accuracy that is similar to gold standard.


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Takashi Yamano ◽  
Atsushi Tanaka ◽  
Takashi Tanimoto ◽  
Shigeho Takarada ◽  
Hiroki Kitabata ◽  
...  

PURPOSE: Sixty-four multi detector computed tomography angiography (64-MDCT) has emerged as a rapidly developing method for the noninvasive detection of coronary artery disease with high negative predictive value and relatively low positive predictive value, especially in patients with intermediate-severity coronary artery disease (ISCAD). There are, however, few studies regarding with optimal threshold for detection of physiologically significant stenosis in 64-MDCT. The purpose of this study was to investigate the optimal threshold for 64-MDCT to detect physiologically significant stenosis using fractional flow reserve of the myocardium (FFRmyo) in patients with ISCAD. METHODS: We enrolled single lesions detected by 64-MDCT of 64 ISCAD patients (age, 68.3 +/− 10.2 years; 78% male). FFRmyo </= 0.75 measured by a 0.014-inch pressure wire was used as the gold standard for presence of physiologically significant stenosis. The area stenosis (%AS) in 64-MDCT were compared with the results of FFRmyo and percent diameter stenosis (%DS) in quantitative coronary angiography (QCA) during elective coronary angiography. Using receiver operating characteristic (ROC) analysis, the optimum threshold for percent area stenosis (%AS) in 64-MDCT was determined in the prediction of FFRmyo </= 0.75. RESULTS: There was an inverse correlation between %AS in 64-MDCT and FFRmyo (65 +/− 20 % and 0.71 +/− 0.16, respectively; r = −0.67; p < 0.01). Furthermore, there was a positive correlation between %AS in 64-MDCT and %DS in QCA (65 +/− 20 % and 63 +/− 19 %, respectively; r = 0.69; p < 0.01). Using a cutoff of 62 %AS in 64-MDCT, ROC curve analysis shows 79 % sensitivity, 85 % specificity, 82% positive predictive value, 83% negative predictive value and 83% accuracy for detecting physiologically significant stenosis. CONCLUSION: > 62 %AS in 64-MDCT could predict the physiologically significant coronary stenosis in patients with ISCAD. Applying an alternative threshold to detect physiologically significant stenosis might contribute to improve the diagnostic accuracy for 64-MDCT in patients with ISCAD.


2016 ◽  
Vol 76 (1) ◽  
pp. 119-125 ◽  
Author(s):  
Aase Haj Hensvold ◽  
Thomas Frisell ◽  
Patrik K E Magnusson ◽  
Rikard Holmdahl ◽  
Johan Askling ◽  
...  

ObjectiveAnti-citrullinated protein antibodies (ACPA) are highly specific for rheumatoid arthritis (RA), but the diagnostic accuracy of ACPA in the general population has not been thoroughly assessed. We aimed to assess the diagnostic accuracy of ACPA for RA in the general population and to further characterise the citrullinated peptide recognition pattern.MethodsSerum samples from a large population-representative twin cohort consisting of 12 590 individuals were analysed for the presence of ACPA using anti-CCP2 ELISA. All ACPA-positive samples were further tested on ELISAs for four peptide-specific ACPA. RA cases were identified by linkage to the Swedish National Patient Register at inclusion and after a median follow-up of 37 months (IQR 31–49).Results350 out of 12 590 individuals had a positive anti-CCP2 test, measuring ACPA. Of these, 103 had an RA diagnosis at the time of blood donation and inclusion. During a median follow-up of 3 years, an additional 21 of the remaining 247 ACPA-positive individuals developed RA. Overall, a positive anti-CCP2 test had a positive predictive value of 29% for prevalent RA at inclusion (negative predictive value of 99.6%). High titres (>3× cut-off) of anti-CCP2 increased the positive predictive value to 48% (negative predictive value of 99.5%). ACPA-positive individuals without RA had lower anti-CCP2 titres and fewer peptide-specific ACPA than ACPA-positive patients with RA and higher C reactive protein levels than ACPA-negative individuals without RA.ConclusionPresence of ACPA and especially high titres of anti-CCP2 have a high diagnostic accuracy for an RA diagnosis in a population setting.


Author(s):  
Danquale Vance Kynshikhar ◽  
Chaman Lal Kaushal ◽  
Ashwani Tomar ◽  
Neeti Aggarwal

Background: To study the diagnostic accuracy of ultrasound in the detection of pneumothorax in chest trauma patients with CT as the Gold Standard Methods: The present study was conducted from 31th July 2018 to 30th July 2019. A total of 36 patients were enrolled in the study. Results: By chest ultrasound, pneumothorax was detected in 15 of 24 patients. The sensitivity of chest ultrasound for the diagnosis of pneumothorax was 62.5%, specificity was 100%, positive predictive value (PPV) was 100%, negative predictive value (NPV) was 54.14% and accuracy was 75%. Conclusion: Chest ultrasound can play an important role in the emergency department aiding a physician for bedside rapid and accurate diagnosis of pneumothorax without interruption in the resuscitation process and without transferring the patient to the radiology section. Keywords: Ultrasound, CT, Pneumothorax


BMJ Open ◽  
2018 ◽  
Vol 8 (9) ◽  
pp. e023766 ◽  
Author(s):  
Selina Nath ◽  
Elizabeth G Ryan ◽  
Kylee Trevillion ◽  
Debra Bick ◽  
Jill Demilew ◽  
...  

ObjectiveTo estimate the population prevalence of anxiety disorders during pregnancy and investigate the diagnostic accuracy of the two-item Generalised Anxiety Disorder scale (GAD-2) for a) GAD and b) any anxiety disorder.DesignCross-sectional survey using a stratified sampling design. Sampling weights were used in the analysis to adjust for the bias introduced by the stratified sampling.SettingInner-city maternity service, South London.Participants545 pregnant women were interviewed after their first antenatal appointment; 528 provided answers on the GAD-2 questions.Main outcome measuresDiagnosis generated by the Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, 4th edition (SCID).ResultsPopulation prevalence of anxiety disorders was 17% (95% CI 12% to 21%): 5% (95% CI 3% to 6%) for GAD, 4% (95% CI 2% to 6%) for social phobia, 8% (95% CI 5% to 11%) for specific phobia and 2% (95% CI 1% to 4%) for obsessive-compulsive disorder. Post-traumatic stress disorder (PTSD) prevalence was unclear due to higher levels of reluctance to respond to PTSD interview questions but sensitivity analyses suggest population prevalence maybe up to 4% (95% CI 2% to 6%). Weighted sensitivity of GAD-2 for GAD (cut-off ≥3) was 69%, specificity 91%, positive predictive value 26%, negative predictive value 98% and likelihood ratio 7.35. For any anxiety disorder the weighted sensitivity was 26%, specificity 91%, positive predictive value 36%, negative predictive value 87% and likelihood ratio 2.92.ConclusionsAnxiety disorders are common but GAD-2 generates many false positives and may therefore be unhelpful in maternity services.


2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Angesom Gebreweld ◽  
Yonas Erkihun ◽  
Daniel Getacher Feleke ◽  
Gebru Hailu ◽  
Temesgen Fiseha

Background. Thrombocytopenia is the most common hematological abnormality in patients with acute malaria. This study aimed to determine the role of thrombocytopenia as a diagnostic marker for malaria in patients with acute febrile illness. Method. A cross-sectional health facility-based study was conducted on 423 consecutively selected acute febrile patients at Ataye District Hospital from February to May 2019 GC. A complete blood count and malaria microscopy were performed for each acute febrile patient. ROC curve analysis was performed to calculate sensitivity, specificity, positive predictive value, and negative predictive value of platelet count in predicting malaria. A P  ≤ 0.05 was considered statistically significant. Result. Out of the 423 acute febrile patients, 73 (17.3%) were microscopically confirmed malaria cases and the rest 350 (82.7%) patients had negative blood film results. Of the microscopically confirmed malaria cases, 55 (75.34%) were P. vivax and 18 (24.66%) were P. falciparum. The prevalence of thrombocytopenia among malaria patients (79.5%) was significantly higher than those in malaria negative acute febrile patients (13.7%), P  < 0.001. About 67% malaria-infected patients had mild to moderate thrombocytopenia and 12.3% had severe thrombocytopenia. The ROC analysis demonstrated platelet counts <150,000/μl as an optimal cutoff value with 0.893 area under the curve, 79.5% sensitivity, 86.3% specificity, 95.3% negative predictive value, and 54.7% positive predictive value to predict malaria. Conclusion. Malaria is still among the major public health problems in the country. Thrombocytopenia is a very good discriminatory test for the presence or absence of malaria with 79.5% sensitivity and 86.3% specificity. Therefore, this may be used in addition to the clinical and microscopic parameters to heighten the suspicion of malaria.


2020 ◽  
pp. emermed-2020-210125
Author(s):  
Svenja L Haak ◽  
Iris JE Renken ◽  
L Cara Jager ◽  
Heleen Lameijer ◽  
Brigitta (Britt) YM van der Kolk

BackgroundA promising modality for diagnosing pulmonary manifestations of COVID-19 in the emergency department (ED) is point-of-care ultrasound (POCUS) of the lungs. The currently used PCR as well as chest X-ray and CT scanning have important disadvantages. The aim of this study is to evaluate the diagnostic accuracy of POCUS in patients with suspected pulmonary manifestations of COVID-19 in the ED.MethodsThis prospective diagnostic accuracy study was conducted at the ED of our non-academic level 1 trauma centre (Isala, Zwolle, the Netherlands). Patients were enrolled between 14 April and 22 April 2020. Patients (aged ≥16 years) with suspected COVID-19 presenting to the ED underwent POCUS. All patients received current standard of care, including PCR (naso-oropharyngeal swab). Outcome of POCUS was compared with PCR or CT scan outcome to determine diagnostic accuracy. Diagnostic accuracy measures were calculated using 2×2 contingency tables.Results100 patients were eligible to participate in this study, data of 93 patients were analysed. 27 (29%) patients were found positive for COVID-19 by PCR or CT. POCUS had a sensitivity of 89% (95% CI 70% to 97%), specificity of 59% (95% CI 46% to 71%), negative predictive value of 93% (95% CI 79% to 98%) and positive predictive value of 47% (95% CI 33% to 61%). In a subgroup of patients without previous cardiopulmonary disease (n=37), POCUS had a sensitivity of 100% (95% CI 70% to 100%), specificity of 76% (95% CI 54% to 90%), negative predictive value of 100% (95% CI 79% to 100%) and positive predictive value of 67% (95% CI 41% to 86%).ConclusionPOCUS of the lungs could serve as a valuable, radiation-free tool for excluding pulmonary manifestations of COVID-19 in patients in the ED at the point of assessment, especially in patients without previous cardiopulmonary disease.Trial registrationDutch Trial Register, No: NTR8544.


2021 ◽  
pp. 22-24
Author(s):  
Monica Sarohi ◽  
Kavita Mardi

Introduction- Milan system is an evidence based system derived from the literature which correlates diagnostic categories with risk of malignancy and clinical management strategies. The goals of this system were to standardize salivary gland cytology reporting across institutions and provide a framework for guiding clinical management. It is a tier based classication having six diagnostic categories. The conventional system was used for diagnosis before the advent of Milan system. In this study, FNAC done for all sa Material and methods- livary gland lesions over a period of two years from 2018 - 2020 in department of pathology, IGMC Shimla are included. All cases are categorized according to MSRSGC and correlated with histopathological follow up wherever available. We calculated the sensitivity, specicity, positive predictive value, negative predictive value and diagnostic accuracy of FNA using the Milan system. We also calculated the ROM was for each category. All the cases were Results: categorized as per MSRSGC and were 14%, 45.4%, 0%, 31.4%, 0.6%, 0.6% and 8% in category I, II, III, IVA, IVB, V and VI respectively. ROM for category I, II, IVA, IVB, V and VI was 0%, 0%, 2.6%, 0%, 100% and 87.5% respectively. The sensitivity, specicity, positive predictive value, negative predictive value and diagnostic accuracy was 98.51%, 66.67%, 98.51%, 66.67% and 97.14% respectively. Milan system is an Discussion: effective tool for diagnosing salivary gland lesions. It offers advantages over the conventional system such as risk of malignancy, management options for each category and a better communication both institute wise and between clinicians and cytopathologists.


Sign in / Sign up

Export Citation Format

Share Document