National Institutes of Health Stroke Scale as an Outcome in Stroke Research: Value of ANCOVA Over Analyzing Change From Baseline

Stroke ◽  
2022 ◽  
Author(s):  
Eva A. Mistry ◽  
Sharon D. Yeatts ◽  
Pooja Khatri ◽  
Akshitkumar M. Mistry ◽  
Michelle Detry ◽  
...  

National Institutes of Health Stroke Scale (NIHSS), measured a few hours to days after stroke onset, is an attractive outcome measure for stroke research. NIHSS at the time of presentation (baseline NIHSS) strongly predicts the follow-up NIHSS. Because of the need to account for the baseline NIHSS in the analysis of follow-up NIHSS as an outcome measure, a common and intuitive approach is to define study outcome as the change in NIHSS from baseline to follow-up (ΔNIHSS). However, this approach has important limitations. Analyzing ΔNIHSS implies a very strong assumption about the relationship between baseline and follow-up NIHSS that is unlikely to be satisfied, drawing into question the validity of the resulting statistical analysis. This reduces the precision of the estimates of treatment effects and the power of clinical trials that use this approach to analysis. ANCOVA allows for the analysis of follow-up NIHSS as the dependent variable while adjusting for baseline NIHSS as a covariate in the model and addresses several challenges of using ΔNIHSS outcome using simple bivariate comparisons (eg, a t test, Wilcoxon rank-sum, linear regression without adjustment for baseline) for stroke research. In this article, we use clinical trial simulations to illustrate that variability in NIHSS outcome is less when follow-up NIHSS is adjusted for baseline compared to ΔNIHSS and how a reduction in this variability improves the power. We outline additional, important clinical and statistical arguments to support the superiority of ANCOVA using the final measurement of the NIHSS adjusted for baseline over, and caution against using, the simple bivariate comparison of absolute NIHSS change (ie, delta).

2021 ◽  
Vol 11 (1) ◽  
pp. 84
Author(s):  
Carlos Bernal-Utrera ◽  
Ernesto Anarte-Lazo ◽  
Juan Jose Gonzalez-Gerez ◽  
Manuel Saavedra-Hernandez ◽  
Elena De-La-Barrera-Aranda ◽  
...  

Postural stability is a little-studied factor in non-specific chronic neck pain; the causes that can alter it are unknown. The relationship with chronic pain could be a determining factor for its deficit. The aim of this study was to investigate the relationship between sustained pain and a postural stability deficit. A randomized and blinded clinical trial (double-blind; placebo control; 12 weeks follow-up) was conducted with a total of 69 subjects divided into three groups, two experimental (manual therapy and specific exercise) and a control treatment, and carried out over a treatment period of three weeks with a follow-up after 12 weeks. Their postural stability was assessed through the overall balance index (OBI). The postural stability of subjects with non-specific chronic neck pain improved in the experimental treatments. There were no statistically significant differences between the experimental groups. This trial found that manual therapy and therapeutic exercise significantly improved OBI compared to the control group. Trial registration: Brazilian Clinical Trial Registry, RBR-2vj7sw.


2000 ◽  
Vol 39 (01) ◽  
pp. 10-15 ◽  
Author(s):  
S. P. Müller ◽  
Ch. Reiners ◽  
A. Bockisch ◽  
Katja Brandt-Mainz

Summary Aim: Tumor scintigraphy with 201-TICI is an established diagnostic method in the follow-up of differentiated thyroid cancer. We investigated the relationship between thyroglobulin (Tg) level and tumor detectability. Subject and methods: We analyzed the scans of 122 patients (66 patients with proven tumor). The patient population was divided into groups with Tg above (N = 33) and below (N = 33) 5 ng/ml under TSH suppression or above (N = 33) and below (N = 33) 50 ng/ml under TSH stimulation. Tumor detectability was compared by ROC-analysis (True-Positive-Fraction test, specificity 90%). Results: There was no significant difference (sensitivity 75% versus 64%; p = 0.55) for patients above and below 5 ng/ml under TSH suppression and a just significant difference (sensitivity 80% versus 58%; p = 0.04) for patients above and below 50 ng/ml under TSH stimulation. In 18 patients from our sample with tumor, Tg under TSH suppression was negative, but 201-TICI-scan was able to detect tumor in 12 patients. Conclusion: Our results demonstrate only a moderate dependence of tumor detectability on Tg level, probably without significant clinical relevance. Even in patients with slight Tg elevation 201-TICI scintigraphy is justified.


2020 ◽  
Author(s):  
Ananta Addala ◽  
Marie Auzanneau ◽  
Kellee Miller ◽  
Werner Maier ◽  
Nicole Foster ◽  
...  

<b>Objective:</b> As diabetes technology use in youth increases worldwide, inequalities in access may exacerbate disparities in hemoglobin A1c (HbA1c). We hypothesized an increasing gap in diabetes technology use by socioeconomic status (SES) would be associated with increased HbA1c disparities. <p> </p> <p><b>Research Design and Methods: </b>Participants aged <18 years with diabetes duration ≥1 year in the Type 1 Diabetes Exchange (T1DX, US, n=16,457) and Diabetes Prospective Follow-up (DPV, Germany, n=39,836) registries were categorized into lowest (Q1) to highest (Q5) SES quintiles. Multiple regression analyses compared the relationship of SES quintiles with diabetes technology use and HbA1c from 2010-2012 and 2016-2018. </p> <p> </p> <p><b>Results: </b>HbA1c was higher in participants with lower SES (in 2010-2012 & 2016-2018, respectively: 8.0% & 7.8% in Q1 and 7.6% & 7.5% in Q5 for DPV; and 9.0% & 9.3% in Q1 and 7.8% & 8.0% in Q5 for T1DX). For DPV, the association between SES and HbA1c did not change between the two time periods, whereas for T1DX, disparities in HbA1c by SES increased significantly (p<0.001). After adjusting for technology use, results for DPV did not change whereas the increase in T1DX was no longer significant.</p> <p> </p> <p><b>Conclusions: </b>Although causal conclusions cannot be drawn, diabetes technology use is lowest and HbA1c is highest in those of the lowest SES quintile in the T1DX and this difference for HbA1c broadened in the last decade. Associations of SES with technology use and HbA1c were weaker in the DPV registry. </p>


2019 ◽  
Vol 23 (3) ◽  
pp. 363-368 ◽  
Author(s):  
Bing Zhou ◽  
Xiao-Chuan Wang ◽  
Jun-Yi Xiang ◽  
Ming-Zhao Zhang ◽  
Bo Li ◽  
...  

OBJECTIVEMechanical thrombectomy using a Solitaire stent retriever has been widely applied as a safe and effective method in adult acute ischemic stroke (AIS). However, due to the lack of data, the safety and effectiveness of mechanical thrombectomy using a Solitaire stent in pediatric AIS has not yet been verified. The purpose of this study was to explore the safety and effectiveness of mechanical thrombectomy using a Solitaire stent retriever for pediatric AIS.METHODSBetween January 2012 and December 2017, 7 cases of pediatric AIS were treated via mechanical thrombectomy using a Solitaire stent retriever. The clinical practice, imaging, and follow-up results were reviewed, and the data were summarized and analyzed.RESULTSThe ages of the 7 patients ranged from 7 to 14 years with an average age of 11.1 years. The preoperative National Institutes of Health Stroke Scale (NIHSS) scores ranged from 9 to 22 with an average of 15.4 points. A Solitaire stent retriever was used in all patients, averaging 1.7 applications of thrombectomy and combined balloon dilation in 2 cases. Grade 3 on the modified Thrombolysis In Cerebral Infarction scale of recanalization was achieved in 5 cases and grade 2b in 2 cases. Six patients improved and 1 patient died after thrombectomy. The average NIHSS score of the 6 cases was 3.67 at discharge. The average modified Rankin Scale score was 1 at the 3-month follow-up. Subarachnoid hemorrhage after thrombectomy occurred in 1 case and that patient died 3 days postoperatively.CONCLUSIONSThis study shows that mechanical thrombectomy using a Solitaire stent retriever has a high recanalization rate and excellent clinical prognosis in pediatric AIS. The safety of mechanical thrombectomy in pediatric AIS requires more clinical trials for confirmation.


Sign in / Sign up

Export Citation Format

Share Document