Surface Plasmon Resonance Characteristics of Optical Fiber Incorporated with Au Nano-Particles in Cladding Region

2016 ◽  
Vol 16 (6) ◽  
pp. 6308-6312 ◽  
Author(s):  
Seongmin Ju ◽  
Seongmook Jeong ◽  
Youngwoong Kim ◽  
Sang-Hyun Lee ◽  
Won-Taek Han
2015 ◽  
Vol 5 (6) ◽  
pp. 1440 ◽  
Author(s):  
Seongmin Ju ◽  
Seongmook Jeong ◽  
Youngwoong Kim ◽  
Sang-Hyun Lee ◽  
Kadathala Linganna ◽  
...  

Sensors ◽  
2019 ◽  
Vol 19 (7) ◽  
pp. 1666 ◽  
Author(s):  
Seongmin Ju ◽  
Won-Taek Han

The effect of γ-ray irradiation on the surface plasmon resonance (SPR) sensing capability of refractive index (n = 1.418–1.448) of the silica glass optical fiber comprised of germano-silicate glass cladding embedded with Au nano-particles (NPs) was investigated. As the γ-ray irradiation increased from 1 h to 3 h with the dose rate of 1190 Gy/h, the morphology of the Au NPs and the SPR spectrum were found to change. The average diameter of Au NPs increased with the aspect ratio from 1 to 2, and the nano-particles became grown to the clusters. The SPR band wavelength shifted towards a longer wavelength with the increase of total dose of γ-ray irradiation regardless of the corresponding refractive indices. The SPR sensitivities (wavelength/refractive index unit, nm/RIU) also increased from 407 nm/RIU to 3553 nm/RIU, 1483 nm/RIU, and 2335 nm/RIU after the γ-ray irradiation at a total dose of 1190 Gy, 2380 Gy, and 3570 Gy, respectively.


Author(s):  
Seongmin Ju ◽  
Won-Taek Han

The effect of γ-ray irradiation on surface plasmon resonance (SPR) sensing capability of refractive index (n = 1.418–1.448) of the silica glass optical fiber comprised of germano-silicate glass cladding embedded with Au nano-particles (NPs) was investigated. As the γ-ray irradiation increased from 1 hour to 3 hours with the dose rate of 1,190 Gy/h, the morphology of the Au NPs and the SPR spectrum were found to change. The average diameter of Au NPs increased with the aspect ratio from 1 to 2 and the nano-particles became grown to the clusters. The SPR peak wavelength shifted towards longer wavelength with the increase of total dose of γ-ray irradiation regardless of the corresponding refractive indices. The SPR sensitivities (wavelength/refractive index unit, nm/RIU) also increased from 407 nm/RIU to 3,553 nm/RIU, 1,483 nm/RIU, and 2,335 nm/RIU after the γ-ray irradiation at the total dose of 1,190 Gy, 2,380 Gy, and 3,570 Gy, respectively.


Sensors ◽  
2021 ◽  
Vol 21 (16) ◽  
pp. 5262
Author(s):  
Qilin Duan ◽  
Yineng Liu ◽  
Shanshan Chang ◽  
Huanyang Chen ◽  
Jin-hui Chen

Surface plasmonic sensors have been widely used in biology, chemistry, and environment monitoring. These sensors exhibit extraordinary sensitivity based on surface plasmon resonance (SPR) or localized surface plasmon resonance (LSPR) effects, and they have found commercial applications. In this review, we present recent progress in the field of surface plasmonic sensors, mainly in the configurations of planar metastructures and optical-fiber waveguides. In the metastructure platform, the optical sensors based on LSPR, hyperbolic dispersion, Fano resonance, and two-dimensional (2D) materials integration are introduced. The optical-fiber sensors integrated with LSPR/SPR structures and 2D materials are summarized. We also introduce the recent advances in quantum plasmonic sensing beyond the classical shot noise limit. The challenges and opportunities in this field are discussed.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Hyeong-Min Kim ◽  
Dae Hong Jeong ◽  
Ho-Young Lee ◽  
Jae-Hyoung Park ◽  
Seung-Ki Lee

AbstractA simple optical fiber sensor based on localized surface plasmon resonance was constructed for direct and rapid measurement of thyroglobulin (Tg). Specific tests for Tg in patients that have undergone thyroidectomy are limited because of insufficient sensitivity, complicated procedures, and in some cases, a long time to yield a result. A sensitive, fast, and simple method is necessary to relieve the psychological and physical burden of the patient. Various concentrations of Tg were measured in a microfluidic channel using an optical fiber sensor with gold nanoparticles. The sensor chip has a detection limit of 93.11 fg/mL with no specificity for other antigens. The potential applicability of the Tg sensing system was evaluated using arbitrary samples containing specific concentrations of Tg. Finally, the sensor can be employed to detect Tg in the patient’s serum, with a good correlation when compared with the commercial kit.


2021 ◽  
Vol 6 (1) ◽  
pp. 26
Author(s):  
Rahat Morad Talukder ◽  
Al Shahriar Hossain Rakib ◽  
Julija Skolnik ◽  
Zohair Usfoor ◽  
Katharina Kaufmann ◽  
...  

In a series of recently published works, we demonstrated that the plasmon-assisted microscopy of nano-objects (PAMONO) technique can be successfully employed for the sizing and quantification of single viruses, virus-like particles, microvesicles and charged non-biological particles. This approach enables label-free, but specific detection of biological nano-vesicles. Hence, the sensor, which was built up utilizing plasmon-assisted microscopy, possesses relative versatility and it can be used as a platform for cell-based assays. However, one of the challenging tasks for such a sensor was the ability to reach a homogeneous illumination of the whole surface of the gold sensor slide. Moreover, in order to enable the detection of even relatively low concentrations of nano-particles, the focused image area had to be expanded. Both tasks were solved via modifications of previously described PAMONO-sensor set ups. Taken together, our latest findings can help to develop a research and diagnostic platform based on the principles of the surface plasmon resonance (SPR)-assisted microscopy of nano-objects.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1516
Author(s):  
Lian Liu ◽  
Shijie Deng ◽  
Jie Zheng ◽  
Libo Yuan ◽  
Hongchang Deng ◽  
...  

An enhanced plastic optical fiber (POF)-based surface plasmon resonance (SPR) sensor is proposed by employing a double-sided polished structure. The sensor is fabricated by polishing two sides of the POF symmetrically along with the fiber axis, and a layer of Au film is deposited on each side of the polished region. The SPR can be excited on both polished surfaces with Au film coating, and the number of light reflections will be increased by using this structure. The simulation and experimental results show that the proposed sensor has an enhanced SPR effect. The visibility and full width at half maximum (FWHM) of spectrum can be improved for the high measured refractive index (RI). A sensitivity of 4284.8 nm/RIU is obtained for the double-sided POF-based SPR sensor when the measured liquid RI is 1.42. The proposed SPR sensor is easy fabrication and low cost, which can provide a larger measurement range and action area to the measured samples, and it has potential application prospects in the oil industry and biochemical sensing fields.


2015 ◽  
Author(s):  
M. F. S. Santiago ◽  
T. B. Silva ◽  
M. H. Mozzini ◽  
I. B. G. Coutinho ◽  
E. S. Medeiros ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document