scholarly journals Determination of Aluminium in Serum: Findings of an External Quality Assessment Scheme

Author(s):  
A. Taylor ◽  
B. J. Starkey ◽  
A. W. Walker
2018 ◽  
Vol 54 (3) ◽  
pp. 159-166 ◽  
Author(s):  
Ewa Młodzińska ◽  
Karolina Bosacka ◽  
Anna Mikołajczyk ◽  
Joanna Rybicka ◽  
Elżbieta Stefaniuk ◽  
...  

The Polish National External Quality Assessment Scheme in Microbiological Diagnostics – POLMICRO programme is organized by the Centre of Quality Control in Microbiology (CQCM). The aim of the POLMICRO 2017 Programme was to evaluate proficiency of laboratories in the identification of microorganisms, determination of susceptibility to antibiotics, detection of resistance mechanisms and interpretation of Gram slides. Bacterial isolates distributed within the Programme differed in their susceptibility to antibiotics and presence of various resistance mechanisms. The paper presents the results of the XXIV edition – POLMICRO 2017.


2020 ◽  
Vol 55 (2) ◽  
pp. 99-106 ◽  
Author(s):  
Ewa Młodzińska ◽  
Karolina Bosacka ◽  
Anna Mikołajczyk ◽  
Joanna Rybicka ◽  
Waleria Hryniewicz

POLMICRO programme – the Polish National External Quality Assessment Scheme in Microbiology is organized by the Centre of Quality Control in Microbiology (CQCM). The aim of the POLMICRO 2018 Programme was to evaluate proficiency of laboratories in the interpretation of Gram slides, identification of microorganisms, determination of susceptibility to antibiotics, detection of resistance mechanisms like ESBL, MBL, KPC, PRP or resistance of staphylococci to methicillin. Bacterial isolates distributed within the Programme differed in their susceptibility to antibiotics and the presence of various resistance mechanisms. The paper presents the results of the XXV edition – POLMICRO 2018.


1994 ◽  
Vol 72 (03) ◽  
pp. 426-429 ◽  
Author(s):  
S Kitchen ◽  
I D Walker ◽  
T A L Woods ◽  
F E Preston

SummaryWhen the International Normalised Ratio (INR) is used for control of oral anticoagulant therapy the same result should be obtained irrespective of the laboratory reagent used. However, in the UK National External Quality Assessment Scheme (NEQAS) for Blood Coagulation INRs determined using different reagents have been significantly different.For 18 NEQAS samples Manchester Reagent (MR) was associated with significantly lower INRs than those obtained using Diagen Activated (DA, p = 0.0004) or Instrumentation Laboratory PT-Fib HS (IL, p = 0.0001). Mean INRs for this group were 3.15, 3.61, and 3.65 for MR, DA, and IL respectively. For 61 fresh samples from warfarin-ised patients with INRs of greater than 3.0 the relationship between thromboplastins in respect of INR was similar to that observed for NEQAS data. Thus INRs obtained with MR were significantly lower than with DA or IL (p <0.0001). Mean INRs for this group were 4.01, 4.40, and 4.59 for MR, DA, and IL respectively.We conclude that the differences between INRs measured with the thromboplastins studied here are sufficiently great to influence patient management through warfarin dosage schedules, particularly in the upper therapeutic range of INR. There is clearly a need to address the issues responsible for the observed discrepancies.


2010 ◽  
Vol 17 (8) ◽  
pp. 1282-1290 ◽  
Author(s):  
Paolo Di Giovine ◽  
Antonella Pinto ◽  
Rose-Marie Ölander ◽  
Dorothea Sesardic ◽  
Paul Stickings ◽  
...  

ABSTRACT Accurate determination of diphtheria toxin antibodies is of value in determining the rates of immunity within broad populations or the immune status of individuals who may be at risk of infection, by assessing responses to vaccination and immunization schedule efficacy. Here we report the results of an external quality assessment (EQA) study for diphtheria serology, performed within the dedicated surveillance network DIPNET. Twelve national laboratories from 11 European countries participated by testing a standard panel of 150 sera using their current routine method: Vero cell neutralization test (NT), double-antigen enzyme-linked immunosorbent assay (ELISA; DAE), dual double-antigen time-resolved fluorescence immunoassay (dDA-DELFIA), passive hemagglutination assay (PHA), toxin binding inhibition assay (ToBI), and in-house or commercial ELISAs. The objective of the study was not to identify the best assay, as the advantages and drawbacks of methods used were known, but to verify if laboratories using their routine method would have categorized (as negative, equivocal, or positive) a serum sample in the same way. The performance of each laboratory was determined by comparing its results on a quantitative and qualitative basis to NT results from a single reference laboratory, as this test is considered the in vitro “gold standard.” The performance of laboratories using NT was generally very good, while the laboratories’ performance using other in vitro methods was variable. Laboratories using ELISA and PHA performed less well than those using DAE, dDA-DELFIA, or ToBI. EQA is important for both laboratories that use in vitro nonstandardized methods and those that use commercial ELISA kits.


2020 ◽  
Vol 55 (4) ◽  
pp. 271-276
Author(s):  
Ewa Młodzińska ◽  
Waleria Hryniewicz

The increase in bacterial resistance to antimicrobials is one of the most serious medical problems, therefore reliable identification in microbiological laboratories is important. The Polish National External Quality Assessment Scheme in Microbiological Diagnostics – POLMICRO programme is organized by the Centre of Quality Control in Microbiology (CQCM) enables the assessment of the competence of Polish microbiological laboratories in the field of identification, determination of susceptibility and detection of drug resistance mechanisms. This work presents the assessment of the results of identification and determination of S. pneumoniae antimicrobial susceptibility obtained by Polish laboratories during the 20 years of experience of the POLMICRO programme.


2017 ◽  
Vol 100 (5) ◽  
pp. 1277-1287 ◽  
Author(s):  
Carolyn Q Burdette ◽  
Johanna E Camara ◽  
Federica Nalin ◽  
Jeanita Pritchett ◽  
Lane C Sander ◽  
...  

Abstract Until recently, the Vitamin D External Quality Assessment Scheme (DEQAS) assessed the performance of various assays for the determination of serum total 25-hydroxyvitamin D [25(OH)D] by using a consensus mean based on the all-laboratory trimmed mean (ALTM) of the approximately 1000 participants' results. Since October 2012, the National Institute of Standardsand Technology (NIST), as part of the Vitamin D Standardization Program, has participated in DEQAS by analyzing the quarterly serum sample sets using an isotope dilution LC-tandem MS (ID LC-MS/MS) reference measurement procedure to assign an accuracy-based target value for serum total 25(OH)D. NIST has analyzed90 DEQAS samples (18 exercises × 5 samples/exercise) to assign target values. The NIST-assigned values are compared with the ALTM and the biases assessed for various assays used by the participants, e.g., LC-MS/MS, HPLC, and several ligand-binding assays. The NIST-value assignment process and the resultsof the analyses of the 90 DEQAS samples are summarized. The absolute mean bias between the NIST-assignedvalues and the ALTM was 5.6%, with 10% of the samples having biases &gt;10%. Benefits of the accuracy-based target values are presented, including for sample sets with high concentrations of 25(OH)D2 and 3-epi-25(OH)D3.