Sizing of Polyp Illustrations Differs by Endoscopists’ Gender and Improves With a Measurement Reference

2019 ◽  
Vol 43 (4) ◽  
pp. 270-273 ◽  
Author(s):  
Nabiha Shamsi ◽  
Aasma Shaukat ◽  
Sofia Halperin-Goldstein ◽  
Joshua Colton

Colorectal cancer surveillance intervals by colonoscopy are based on the size and number of polyps removed. Evidence suggests endoscopists’ estimation of polyp size is often inaccurate, but the differences by endoscopists’ characteristics have not been reported. This study assesses endoscopists’ accuracy of measuring polyp illustrations, the effect of endoscopists’ characteristics, and the impact of having a measurement reference. Endoscopists in a community-based, gastroenterology practice estimated the size of several illustrations in a booklet. One month later, they estimated the size of illustrations with a provided measurement reference. Accuracy was defined as no difference between estimated and actual value. Endoscopists were accurate in sizing only 15% of the time, with a tendency toward undersizing. Female endoscopists, those with less than 10 years in practice and those with lower adenoma detection rates, were more likely to undersize polyps. Accuracy of measuring the polyp illustrations increased to 50% ( p < .01) with the measurement reference. The improvement in accuracy was seen across endoscopists’ demographic groups. Endoscopists had poor accuracy of measuring polyp illustrations. Almost universally, endoscopists tended to undersize the polyp illustrations. Accuracy improved significantly with the use of a polyp-measuring guide, particularly when considering important surveillance thresholds of 5 and 10 mm.

2018 ◽  
Vol 32 (7) ◽  
pp. 3108-3113 ◽  
Author(s):  
Jamie M. Tjaden ◽  
Jessica A. Hause ◽  
Daniel Berger ◽  
Samantha K. Duveneck ◽  
Shriram M. Jakate ◽  
...  

2017 ◽  
Vol 112 ◽  
pp. S54-S55
Author(s):  
Joseph Marsano ◽  
Gabriela Kuftinec ◽  
Brian Paciotti ◽  
Machelle Wilson ◽  
Sheeva Johnson ◽  
...  

Endoscopy ◽  
2017 ◽  
Vol 50 (02) ◽  
pp. 159-176 ◽  
Author(s):  
Sophie Restellini ◽  
Omar Kherad ◽  
Charles Menard ◽  
Myriam Martel ◽  
Alan Barkun

Abstract Background and study aims Recommendations on adjuvant use with bowel preparations remain disparate. We performed a meta-analysis determining the clinical impact of adding an adjuvant to polyethylene glycol (PEG), sodium phosphate, picosulfate (PICO), or oral sulfate solutions (OSS)-based regimens. Methods Systematic searches were made of MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials from January 1980 to April 2016 that assessed preparations with or without adjuvants, given in split and non-split dosing, and PEG high- (> 3 L) or low-dose (≤ 2 L) regimens. Bowel cleansing efficacy was the primary outcome. Secondary outcomes included patient willingness to repeat the procedure, and polyp and adenoma detection rates. Results Of 3093 citations, 77 trials fulfilled the inclusion criteria. Overall, addition of an adjuvant compared with no adjuvant, irrespective of the type of preparation and mode of administration, yielded improvements in bowel cleanliness (odds ratio [OR] 1.23 [1.01 – 1.51]) without greater willingness to repeat (OR 1.40 [0.91 – 2.15]). Adjuvants combined with high-dose PEG significantly improved colon cleansing (OR 1.96 [1.32 – 2.94]). The odds for achieving adequate preparation with low-dose PEG with an adjuvant were not different to high-dose PEG alone (OR 0.95 [0.73 – 1.22]), but yielded improved tolerance (OR 3.22 [1.85 – 5.55]). However, split high-dose PEG yielded superior cleanliness to low-dose PEG with adjuvants (OR 2.53 [1.25 – 5.13]). No differences were noted for OSS and PICO comparisons, or for any products regarding polyp or adenoma detection rates. Conclusions Critical heterogeneity precludes firm conclusion on the impact of adjuvants with existing bowel preparations. Additional research is required to better characterize the methods of administration and resulting roles of adjuvants in an era of split-dosing.


Endoscopy ◽  
2019 ◽  
Vol 52 (01) ◽  
pp. 45-51 ◽  
Author(s):  
Guido von Figura ◽  
Moritz Hasenöhrl ◽  
Bernhard Haller ◽  
Alexander Poszler ◽  
Jörg Ulrich ◽  
...  

Abstract Background Cap-assisted colonoscopy is frequently used to facilitate adenoma detection during endoscopy. However, data on how cap assistance influences polyp resection are scarce. We aimed to evaluate the impact of cap assistance with the Endocuff vision device (EVD) on the resection time for colorectal polyps in patients undergoing colonoscopy. Methods A randomized, prospective study was performed in a university hospital in Germany. A total of 250 patients were randomly assigned 1:1 to undergo either colonoscopy with the EVD (EVD arm) or standard colonoscopy without the use of a cap (standard arm). The primary outcome was the average duration of polypectomy. Secondary outcomes included adenoma detection rate, cecal and ileal intubation times, and propofol dosage. Results The use of EVD led to a significant reduction in the median polypectomy time in the EVD vs. standard arm (54 vs. 80 seconds, respectively; P = 0.02). This effect was strongest for polyps ≥ 6 mm. Compared with the standard group, Endocuff assistance also resulted in a shorter cecal intubation time (6 vs. 8 minutes; P = 0.03) and overall colonoscopy time (23 vs. 27 minutes; P = 0.02). In contrast, no difference in withdrawal time was observed. The polyp and adenoma detection rates did not differ significantly between the two groups. Conclusion Endocuff-assisted colonoscopy reduces the duration of polypectomy, which may be due to a more stable scope position during resection. Further studies are needed to investigate whether comparable effects will be seen for other interventions, such as clipping or biopsy sampling.


2019 ◽  
Vol 07 (12) ◽  
pp. E1585-E1591 ◽  
Author(s):  
Joseph Marsano ◽  
Sheeva Johnson ◽  
Stephanie Yan ◽  
Latifat Alli-Akintade ◽  
Machelle Wilson ◽  
...  

Abstract Objectives and study aim Colonoscopy prevents colorectal cancer by removing adenomatous polyps, but missed adenomas lead to interval cancers. Different devices have been used to increase adenoma detection rates (ADR). Two such devices of interest are the transparent cap (Olympus) and Endocuff (ARC Medical). Our study aimed to compare differences in ADR between Endocuff-assisted colonoscopy (EAC), cap-assisted colonoscopy (CAC) and standard colonoscopy (SC). Patients and methods A sample size of 126 subjects was calculated to determine an effect size of 30 %. Patients undergoing screening or surveillance colonoscopy between March 2016 and January 2017 were randomized to SC, CAC or EAC groups. Three experienced endoscopists performed all colonoscopies. Patient demographics, procedure indication, Boston Bowel Prep Score (BBPS), withdrawal time, polyp size, location, histopathology, were analyzed. Results There was no difference in ADR (52 %, 40 % and 54 %) in the SC, CAC and EAC groups respectively (P = 0.4). Similar findings were also observed for proximal ADR (45 %, 35 %, and 50 %, P = 0.4) and SSA detection rate (16 %, 14 %, and 23 %, P = 0.5). EAC detected higher mean ADR per colonoscopy compared to CAC (1.70 vs 0.76, P = 0.01). However, there was no significant difference in mean ADR per positive colonoscopy (2.08, 1.63, and 2.59, P = 0.21). Conclusion In a randomized controlled trial comparing AC to CAC and SC, neither device conferred additional benefits in ADR among high detectors. When comparing each device, EAC may be better than CAC at detecting more total adenomas.


2010 ◽  
Vol 105 ◽  
pp. S568 ◽  
Author(s):  
Diego Valencia ◽  
Mark Metwally ◽  
Victor Ciofoaia ◽  
Annie Gaudioso ◽  
William Hale ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document