Testing of Polymer Materials: What Methods Should be Used?

1991 ◽  
Vol 19 (2) ◽  
pp. 222-225
Author(s):  
Per Kjellstrand ◽  
Ulf Boberg

Tests, performed over a ten-year period, on 653 polymers intended for use in extracorporeal renal replacement therapy, were evaluated. The test battery used included animal tests, in vitro tests and chemical tests. Some tests were found to have a very low sensitivity. Thus, acute systemic toxicity testing in mice with sodium chloride, ethanol or paraffin oil as extractants was performed on a total of 806 occasions. Only two of these resulted in a “fail” decision. The final outcome of the tests for the majority of materials could be predicted by the results of the UV absorption, chloride, inhibition of cell growth, and tin tests. Of the materials that passed these four tests, less than 2% were not approved on the basis of the whole test battery. The experiments show that only a limited number of tests have to be performed when testing polymers intended for use in extracorporeal renal replacement therapy.

1990 ◽  
Vol 18 (1_part_1) ◽  
pp. 103-116
Author(s):  
Sven Hellberg ◽  
Lennart Eriksson ◽  
Jörgen Jonsson ◽  
Fredrik Lindgren ◽  
Michael Sjöström ◽  
...  

Estimating the toxicity to humans of chemicals by testing on human subjects is not considered to be ethically acceptable, and toxicity testing on laboratory animals is also questionable. Therefore, there is a need for alternative methods that will give estimates of various aspects of human toxicity. Batteries of in vitro tests, together with physicochemical and toxicokinetic data, analysed by efficient data analytical methods, may enable analogy models to be constructed that can predict human toxicity. It may be possible to model non-specific toxicity relating to lipophilicity, or basal cytotoxicity, for a series of diverse compounds with large variation in chemical structure and physicochemical properties. However, local models for a series of similar compounds are generally expected to be more accurate, as well as being capable of modelling more-specific interactions. Analogy models for the prediction of human toxicity are discussed and exemplified with physicochemical and cytotoxicity data from the first ten chemicals in the multicenter evaluation of in vitro cytotoxicity (MEIC) project.


1997 ◽  
Vol 25 (3) ◽  
pp. 343-345
Author(s):  
Ethel Thurston

The Multicenter Evaluation of In Vitro Cytotoxicity programme is most important to animal protection, since it has validated 64 in vitro tests using advanced human data for 50 chemicals as the “gold standard”. Therefore, it has been able to compare animal cell tests, human cell tests and whole-animal tests fairly with unbiased scientific evidence. Added bonuses have included the identification and development of missing in vitro information (“missing tests”), publication of time-related lethal blood concentrations for all 50 chemicals, and some preliminary plans to resolve the 50,000 untested (or poorly tested) chemicals in the chemical mountain.


1995 ◽  
Vol 23 (4) ◽  
pp. 491-496
Author(s):  
Hanna Tähti ◽  
Leila Vaalavirta ◽  
Tarja Toimela

— There are several hundred industrial chemicals with neurotoxic potential. The neurotoxic risks of most of these chemicals are unknown. Additional methods are needed to assess the risks more effectively and to elucidate the mechanisms of neurotoxicity more accurately than is possible with the conventional methods. This paper deals with general tasks concerning the use of in vitro models in the evaluation of neurotoxic risks. It is based on our previous studies with various in vitro models and on recent literature. The induction of glial fibrillary acidic protein in astrocyte cultures after treatment with known neurotoxicants (mercury compounds and aluminium) is discussed in more detail as an important response which can be detected in vitro. When used appropriately with in vivo tests and with previous toxicological data, in vitro neurotoxicity testing considerably improves risk assessment. The incorporation of in vitro tests into the early stages of risk evaluation can reduce the number of animals used in routine toxicity testing, by identifying chemicals with high neurotoxic potential.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Lauren Andrews ◽  
Scott Benken ◽  
Xing Tan ◽  
Eric Wenzler

Abstract Background To evaluate the transmembrane clearance (CLTM) of apixaban during modeled in vitro continuous renal replacement therapy (CRRT), assess protein binding and circuit adsorption, and provide initial dosing recommendations. Methods Apixaban was added to the CRRT circuit and serial pre-filter bovine blood samples were collected along with post-filter blood and effluent samples. All experiments were performed in duplicate using continuous veno-venous hemofiltration (CVVH) and hemodialysis (CVVHD) modes, with varying filter types, flow rates, and point of CVVH replacement fluid dilution. Concentrations of apixaban and urea were quantified via liquid chromatography-tandem mass spectrometry. Plasma pharmacokinetic parameters for apixaban were estimated via noncompartmental analysis. CLTM was calculated via the estimated area under the curve (AUC) and by the product of the sieving/saturation coefficient (SC/SA) and flow rate. Two and three-way analysis of variance (ANOVA) models were built to assess the effects of mode, filter type, flow rate, and point of dilution on CLTM by each method. Optimal doses were suggested by matching the AUC observed in vitro to the systemic exposure demonstrated in Phase 2/3 studies of apixaban. Linear regression was utilized to provide dosing estimations for flow rates from 0.5–5 L/h. Results Mean adsorption to the HF1400 and M150 filters differed significantly at 38 and 13%, respectively, while mean (± standard deviation, SD) percent protein binding was 70.81 ± 0.01%. Effect of CVVH point of dilution did not differ across filter types, although CLTM was consistently significantly higher during CRRT with the HF1400 filter compared to the M150. The three-way ANOVA demonstrated improved fit when CLTM values calculated by AUC were used (adjusted R2 0.87 vs. 0.52), and therefore, these values were used to generate optimal dosing recommendations. Linear regression revealed significant effects of filter type and flow rate on CLTM by AUC, suggesting doses of 2.5–7.5 mg twice daily (BID) may be needed for flow rates ranging from 0.5–5 L/h, respectively. Conclusion For CRRT flow rates most commonly employed in clinical practice, the standard labeled 5 mg BID dose of apixaban is predicted to achieve target systemic exposure thresholds. The safety and efficacy of these proposed dosing regimens warrants further investigation in clinical studies.


2014 ◽  
Vol 36 (3) ◽  
pp. 19-25 ◽  
Author(s):  
Fiona Reynolds ◽  
Carl Westmoreland ◽  
Julia Fentem

New informatics capabilities and computational and mathematical modelling techniques, used in combination with highly sensitive molecular biology and mechanistic chemistry approaches, are transforming the way in which we assess the safety of chemicals and products. In recent years, good progress has been made in replacing some of the animal tests required for regulatory purposes with methods using cells and tissues in vitro. Nevertheless, big scientific challenges remain in developing relevant non-animal models able to predict the effects of chemicals which are absorbed systemically. The greatest breakthroughs in non-animal approaches for chemical safety assessment will most likely result from continued multi-disciplinary research investment in predictive (integrative and systems) biology. Some of our current research in this area is described in the present article.


2021 ◽  
Vol 12 ◽  
Author(s):  
M G Vossen ◽  
S Pferschy ◽  
C Milacek ◽  
M Haidinger ◽  
Mario Karolyi ◽  
...  

Background: Elimination of a drug during renal replacement therapy is not only dependent on flow rates, molecular size and protein binding, but is often influenced by difficult to predict drug membrane interactions. In vitro models allow for extensive profiling of drug clearance using a wide array of hemofilters and flow rates. We present a bovine blood based in vitro pharmacokinetic model for intermittent renal replacement therapy.Methods: Four different drugs were analyzed: gentamicin, doripenem, vancomicin and teicoplanin. The investigated drug was added to a bovine blood reservoir connected to a hemodialysis circuit. In total seven hemofilter models were analyzed using commonly employed flow rates. Pre-filter, post-filter and dialysate samples were drawn, plasmaseparated and analyzed using turbidimetric assays or HPLC. Protein binding of doripenem and vancomycin was measured in bovine plasma and compared to previously published values for human plasma.Results: Clearance values were heavily impacted by choice of membrane material and surface as well as by dialysis parameters such as blood flow rate. Gentamicin clearance ranged from a minimum of 90.12 ml/min in a Baxter CAHP-170 diacetate hemofilter up to a maximum of 187.90 ml/min in a Fresenius medical company Fx80 polysulfone model (blood flow rate 400 ml/min, dialysate flow rate 800 ml/min). Clearance of Gentamicin vs Vancomicin over the F80s hemofilter model using the same flow rates was 137.62 mL vs 103.25 ml/min. Doripenem clearance with the Fx80 was 141.25 ml/min.Conclusion: Clearance values corresponded very well to previously published data from clinical pharmacokinetic trials. In conjunction with in silico pharmacometric models. This model will allow precise dosing recommendations without the need of large scale clinical trials.


2020 ◽  
pp. 039139882097614
Author(s):  
Frédéric J Baud ◽  
Vincent Jullien ◽  
Tarik Abarou ◽  
Benoît Pilmis ◽  
Jean-Herlé Raphalen ◽  
...  

Introduction: Continuous renal replacement therapy (CRRT) efficiently eliminates fluconazole. However, the routes of elimination were not clarified. Adsorption of fluconazole by filters is a pending question. We studied the elimination of fluconazole in a model mimicking a session of CRRT in humans using the NeckEpur® model. Two filters were studied. Methods: The AV1000®-polysulfone filter with the Multifiltrate Pro. Fresenius and the ST150®-polyacrylonitrile filter with the Prismaflex. Baxter-Gambro were studied. Continuous filtration used a flowrate of 2.5 L/h in post-dilution only. Session were made in duplicate. Routes of elimination were assessed using the NeckEpur® model. Results: The mean measured initial fluconazole concentration (mean ± SD) for the four sessions in the central compartment (CC) was 14.9 ± 0.2 mg/L. The amount eliminated from the CC at the end of 6 h-session at a 2.5 L/h filtration flowrate for the AV1000®-polysulfone and the ST150®-polyacrylonitrile filters were 90%–93% and 96%–94%, respectively; the clearances from the central compartment (CC) were 2.5–2.6 and 2.4–2.3 L/h, respectively. The means of the instantaneous sieving coefficient were 0.94%–0.91% and 0.99%–0.91%, respectively. The percentages of the amount eliminated from the CC by filtration/adsorption were 100/0%–95/5% and 100/0%–100/0%, respectively. Conclusion: Neither the ST150®-polyacrylonitrile nor the AV1000®-polysulfone filters result in any significant adsorption of fluconazole.


2010 ◽  
Vol 29 (1) ◽  
pp. 11-14 ◽  
Author(s):  
Robert F Phalen

Toxicity Testing in the 21st Century: A Vision and a Strategy (NRC, 2007) presents a bold plan for chemical toxicity testing that replaces whole-animal tests with cell-culture, genetic, other in-vitro techniques, computational methods, and human monitoring. Although the proposed vision is eloquently described, and recent advances in in-vitro and in-silico methods are impressive, it is difficult believe that replacing in-vitro testing is either practical or wise. It is not clear that the toxicity-related events that occur in whole animals can be adequately replicated using the proposed methods. Protecting public health is a serious endeavor that should not be limited by denying animal testing. Toxicologists and regulators are encouraged to read the report, carefully consider its implications, and share their thoughts. The vision is for too important to ignore.