animal testing
Recently Published Documents


TOTAL DOCUMENTS

673
(FIVE YEARS 215)

H-INDEX

28
(FIVE YEARS 7)

2022 ◽  
Vol 9 (2) ◽  
pp. 55-62
Author(s):  
Rahman et al. ◽  

With the advent of medical technology and science, the number of animals used in research has increased. For decades, the use of animals in research and product testing has been a point of conflict. Experts and pharmaceutical manufacturers are harming animals worldwide during laboratory research. Animals have also played a significant role in the advancement of science; animal testing has enabled the discovery of various novel drugs. The misery, suffering, and deaths of animals are not worth the potential human benefits. As a result, animals must not be exploited in research to assess the drug mechanism of action (MOA). Apart from the ethical concern, animal testing has a few more downsides, including the requirement for skilled labor, lengthy processes, and cost. Because it is critical to investigate adverse effects and toxicities in the development of potentially viable drugs. Assessment of each target will consume the range of resources as well as disturb living nature. As the digital twin works in an autonomous virtual world without influencing the physical structure and biological system. Our proposed framework suggests that the digital twin is a great reliable model of the physical system that will be beneficial in assessing the possible MOA prior to time without harming animals. The study describes the creation of a digital twin to combine the information and knowledge obtained by studying the different drug targets and diseases. Mechanism of Action using Digital twin (MOA-DT) will enable the experts to use an innovative approach without physical testing to save animals, time, and resources. DT reflects and simulates the actual drug and its relationships with its target, however presenting a more accurate depiction of the drug, which leads to maximize efficacy and decrease the toxicity of a drug. In conclusion, it has been shown that drug discovery and development can be safe, effective, and economical in no time through the combination of the digital and physical models of a pharmaceutical as compared to experimental animals.


2022 ◽  
Vol 12 ◽  
Author(s):  
Abdulkarim Najjar ◽  
Andreas Schepky ◽  
Christopher-Tilman Krueger ◽  
Matthew Dent ◽  
Sophie Cable ◽  
...  

Ethical and legal considerations have led to increased use of non-animal methods to evaluate the safety of chemicals for human use. We describe the development and qualification of a physiologically-based kinetics (PBK) model for the cosmetic UV filter ingredient, homosalate, to support its safety without the need of generating further animal data. The intravenous (IV) rat PBK model, using PK-Sim®, was developed and validated using legacy in vivo data generated prior to the 2013 EU animal-testing ban. Input data included literature or predicted physicochemical and pharmacokinetic properties. The refined IV rat PBK model was subject to sensitivity analysis to identify homosalate-specific sensitive parameters impacting the prediction of Cmax (more sensitive than AUC(0-∞)). These were then considered, together with population modeling, to calculate the confidence interval (CI) 95% Cmax and AUC(0-∞). Final model parameters were established by visual inspection of the simulations and biological plausibility. The IV rat model was extrapolated to oral administration, and used to estimate internal exposures to doses tested in an oral repeated dose toxicity study. Next, a human PBK dermal model was developed using measured human in vitro ADME data and a module to represent the dermal route. Model performance was confirmed by comparing predicted and measured values from a US-FDA clinical trial (Identifier: NCT03582215, https://clinicaltrials.gov/). Final exposure estimations were obtained in a virtual population and considering the in vitro and input parameter uncertainty. This model was then used to estimate the Cmax and AUC(0–24 h) of homosalate according to consumer use in a sunscreen. The developed rat and human PBK models had a good biological basis and reproduced in vivo legacy rat and human clinical kinetics data. They also complied with the most recent WHO and OECD recommendations for assessing the confidence level. In conclusion, we have developed a PBK model which predicted reasonably well the internal exposure of homosalate according to different exposure scenarios with a medium to high level of confidence. In the absence of in vivo data, such human PBK models will be the heart of future completely non-animal risk assessments; therefore, valid approaches will be key in gaining their regulatory acceptance.Clinical Trial Registration: https://clinicaltrials.gov/, identifier, NCT03582215


Author(s):  
Shokoofeh Abbaszadeh ◽  
Roberto Leidhold ◽  
Stefan Hoerner

AbstractFish mortality assessments for turbine passages are currently performed by live-animal testing with up to a hundred thousand fish per year in Germany. A propelled sensor device could act as a fish surrogate. In this context, the study presented here investigates the state of the art via a thorough literature review on propulsion systems for aquatic robots. An evaluation of propulsion performance, weight, size and complexity of the motion achievable allows for the selection of an optimal concept for such a fish mimicking device carrying the sensors. In the second step, the design of a bioinspired soft robotic fish driven by an unconventional drive system is described. It is based on piezoceramic actuators, which allow for motion with five degrees of freedom (DOF) and the creation of complex bio-mimicking body motions. A kinematic model for the motion’s characteristics is developed, to achieve accurate position feedback with the use of strain gauges. Optical measurements validate the complex deformation of the body and deliver the basis for the calibration of the kinematic model. Finally, it can be shown, that the calibrated model presented allows the tracking of the deformation of the entire body with an accuracy of 0.1 mm.


Toxins ◽  
2022 ◽  
Vol 14 (1) ◽  
pp. 31
Author(s):  
Jeroen L. A. Pennings ◽  
Eric Abachin ◽  
Raphaël Esson ◽  
Hennie Hodemaekers ◽  
Antoine Francotte ◽  
...  

Background: Ensuring consistency of tetanus neurotoxin (TeNT) production by Clostridium tetani could help to ensure consistent product quality in tetanus vaccine manufacturing, ultimately contributing to reduced animal testing. The aim of this study was to identify RNA signatures related to consistent TeNT production using standard and non-standard culture conditions. Methods: We applied RNA sequencing (RNA-Seq) to study C. tetani gene expression in small-scale batches under several culture conditions. Results: We identified 1381 time-dependent differentially expressed genes (DEGs) reflecting, among others, changes in growth rate and metabolism. Comparing non-standard versus standard culture conditions identified 82 condition-dependent DEGs, most of which were specific for one condition. The tetanus neurotoxin gene (tetX) was highly expressed but showed expression changes over time and between culture conditions. The tetX gene showed significant down-regulation at higher pH levels (pH 7.8), which was confirmed by the quantification data obtained with the recently validated targeted LC-MS/MS approach. Conclusions: Non-standard culture conditions lead to different gene expression responses. The tetX gene appears to be the best transcriptional biomarker for monitoring TeNT production as part of batch-to-batch consistency testing during tetanus vaccine manufacturing.


2022 ◽  
Vol 52 (6) ◽  
Author(s):  
Vinicius Duarte ◽  
Adriano Olnei Mallmann ◽  
Camila Tonini ◽  
Diogo Liberalesso ◽  
Cristiane Rosa da Silva ◽  
...  

ABSTRACT: In vitro tests are performed to evaluate the efficacy of antimycotoxins additives (AMAs); nevertheless, such assays show a low correlation with in vivo trials, which are also required to determine AMAs’ efficacy. In search of an alternative method, the current study investigated the use of an ex vivo technique. Six AMAs (AMA1 to AMA6) had their ability to reduce intestinal absorption of aflatoxin B1 (AFB1) evaluated. Jejunal explants were obtained from broilers and subjected to two treatments per AMA in Ussing chambers: T1 (control) - 2.8 mg/L AFB1, and T2 - 2.8 mg/L AFB1 + 0.5% AMA. AMAs were also tested in vitro to assess adsorption of AFB1 in artificial intestinal fluid. In the ex vivo studies, AMA1 to AMA6 decreased intestinal absorption of AFB1 by 67.11%, 73.82%, 80.70%, 85.86%, 86.28% and 82.32%, respectively. As for the in vitro results, AMA1 to AMA6 presented an adsorption of 99.72%, 99.37%, 99.67%, 99.53%, 99.04% and 99.15%, respectively. The evaluated ex vivo model proved useful in the assessment of AMAs. No correlation was reported between ex vivo and in vitro findings. Further studies are needed to elucidate the correlation between ex vivo and in vivo results seeking to reduce animal testing.


2021 ◽  
Author(s):  
Jianhua Zhang ◽  
Julia Griesbach ◽  
Marsel Ganeyev ◽  
Anna-Katharina Zehnder ◽  
Peng Zeng ◽  
...  

Abstract Mechanical loading has been shown to influence various osteogenic responses of bone-derived cells and bone formation in vivo. However, the influence of mechanical stimulation on the formation of bone organoid in vitro is not clearly understood. Here, 3D bioprinted human mesenchymal stem cells (hMSCs)-laden graphene oxide composite scaffolds were cultured in cyclic-loading bioreactors for up to 56 days. Our results showed that mechanical loading from day 1 (ML01) significantly increased organoid mineral density, organoid stiffness, and osteoblast differentiation compared with non-loading and mechanical loading from day 21. Importantly, ML01 stimulated collagen I maturation, osteocyte differentiation, lacunar-canalicular network formation and YAP expression on day 56. These finding are the first to reveal that long-term mechanical loading is required for the formation of 3D bioprinted functional osteocyte bone organoids. Such 3D bone organoids may serve as a human-specific alternative to animal testing for the study of bone pathophysiology and drug screening.


Sci ◽  
2021 ◽  
Vol 3 (4) ◽  
pp. 45
Author(s):  
Eleonore Fröhlich

Animal testing is mandatory in drug testing and is the gold standard for toxicity and efficacy evaluations. This situation is expected to change in the future as the 3Rs principle, which stands for the replacement, reduction, and refinement of the use of animals in science, is reinforced by many countries. On the other hand, technologies for alternatives to animal testing have increased. The need to develop and use alternatives depends on the complexity of the research topic and also on the extent to which the currently used animal models can mimic human physiology and/or exposure. The lung morphology and physiology of commonly used animal species differs from that of human lungs, and the realistic inhalation exposure of animals is challenging. In vitro and in silico methods can assess important aspects of the in vivo effects, namely particle deposition, dissolution, action at, and permeation through, the respiratory barrier, and pharmacokinetics. This review discusses the limitations of animal models and exposure systems and proposes in vitro and in silico techniques that could, when used together, reduce or even replace animal testing in inhalation testing in the future.


2021 ◽  
Vol 41 (12) ◽  
pp. 18-19
Author(s):  
Gary Michelson ◽  
Aysha Akhtar

Sign in / Sign up

Export Citation Format

Share Document