A Pivot Bearing-Supported Centrifugal Pump for a Long-Term Assist Heart

1997 ◽  
Vol 20 (4) ◽  
pp. 222-228 ◽  
Author(s):  
T. Nakazawa ◽  
Y. Ohara ◽  
R. Benkowski ◽  
K. Makinouchi ◽  
Y. Takami ◽  
...  

A pivot bearing-supported centrifugal blood pump has been developed. It is a compact, cost effective, and anti-thrombogenic pump with anatomical compatibility. A preliminary evaluation of five paracorporeal left ventricular assist studies were performed on pre-conditioned bovine (70-100 kg), without cardiopulmonary bypass and aortic cross-clamping. The inflow cannula was inserted into the left ventricle (LV) through the apex and the outflow cannula affixed with a Dacron vascular graft was anastomosed to the descending aorta. All pumps demonstrated trouble free performance over a two-week screening period. Among these five studies, three implantations were subjected for one month system validation studies. All the devices were trouble free for longer than 1 month. (35, 34, and 31 days). After achieving one month studies, all experiments were terminated. There was no evidence of device induced thrombus formation inside the pump. The plasma free hemoglobin levels were within normal ranges throughout all experiments. As a consequence of these studies, a mass production model C1E3 of this pump was fabricated as a short-term assist pump. This pump has a Normalized Index of Hemolysis of 0.0007 mg/100L and the estimated wear life of the impeller bearings is longer than 8 years. The C1E3 will meet the clinical requirements as a cardiopulmonary bypass pump. For the next step, a miniaturized pivot bearing centrifugal blood pump PI-601 has been developed for use as a permanently implantable device after design optimization. The evolution from C1E3 to the PI-601 converts this pivot bearing centrifugal pump as a totally implantable centrifugal pump. A pivot bearing centrifugal pump will become an ideal assist pump for the patients with failing heart.

1987 ◽  
Vol 109 (3) ◽  
pp. 272-278 ◽  
Author(s):  
Shinobu Tanaka ◽  
Shuzo Yamamoto ◽  
Ken-ichi Yamakoshi ◽  
Akira Kamiya

A new compact centrifugal blood pump driven by a miniature DC servomotor has been designed for use for short-term extra corporeal and cardiac-assisted circulation. The impeller of the pump was connected directly to the motor by using a simple-gear coupling. The shaft for the impeller was sealed from blood by both a V-ring and a seal bearing. Either pulsatile or nonpusatile flow was produced by controlling the current supply to the motor. The pump characteristics and the degree of hemolysis were evaluated with regard to the configuration of the impeller with a 38-mm outer diameter in vitro tests; the impeller having the blade angles at the inlet of 20 deg and at the outlet of 50 deg was the most appropriate as a blood pump. The performance in an operation, hemolysis and thrombus formation in the pump were assessed by a left ventricular bypass experiment in dogs. It was suggested by this study that this prototype pump appears promising for use not only in animal experiments but also in clinical application.


2003 ◽  
Vol 03 (02) ◽  
pp. 187-196
Author(s):  
Y. Lee ◽  
J. K. Chang ◽  
S. H. Lee ◽  
J. U. Jang ◽  
K. B. Lee ◽  
...  

An ideal blood pump would provide sufficient flow rate against vessel pressure without hemolysis or thrombus formation. In preceding studies, it is known that non-contact operation by magnetic bearing system gives high mechanical reliability, low hemolysis and low thrombus formation. Therefore, in the present study a magnetically suspended vaneless centrifugal blood pump (MSVC-BP) has been developed for the use of cardiopulmonary bypass, in which the magnetic suspension centers the centrifugal rotor avoiding any contact. To predict the flow pattern in the pump head and to calculate shear stress on the rotor, numerical analysis has been performed using the TASCflow®. In vitro tests of hydrodynamic performance of the present pump have been carried out in mock circular system with glycerin solution, attaining a maximum flow rate of 12 L/min at 2200 rpm. In vivo tests of hemodynamic performance of the pump have also led to reasonable results for clinical usage.


Perfusion ◽  
1997 ◽  
Vol 12 (5) ◽  
pp. 335-341 ◽  
Author(s):  
Yoshiyuki Takami ◽  
Yasuhisa Ohara ◽  
Goro Otsuka ◽  
Tadashi Nakazawa ◽  
Yukihiko Nosé

1997 ◽  
Vol 20 (10) ◽  
pp. 562-569 ◽  
Author(s):  
T. Yamada ◽  
K. Nishimura ◽  
T. Akamatsu ◽  
T. Tsukiya ◽  
C.H. Park ◽  
...  

The life of currently-available centrifugal pumps is limited to no more than three days. As a magnetically suspended centrifugal pump (MSCP) contains no shaft or seal, it could be expected to have a longer life expectancy. The MSCP was evaluated in a chronic animal model using eight adult sheep. Left ventricular assist with the MSCP was instituted between the left atrium and the descending aorta. The flow rates ranged from 2.5 to 6.0 L/min. The duration of the experiments ranged from 14 to 60 days. No mechanical failure occurred. The plasma free hemoglobin levels remained within an acceptable range (3-19 mg/dL). No reduction in the counts of red blood cells or platelets was observed. Thrombus formation within the MSCP was recognized in one pump. The main reason for termination was thromboembolism derived from the circuits. Three types of regulation methods (constant rotational speed, constant motor current, and controlled motor current) were also investigated. Regulation by a constant motor current mode altered the pressure-flow (P-Q) characteristics, and thereby, a steadier pump flow was obtained compared with regulation in the constant rotational speed mode. Moreover, the controlled motor current mode can change the P-Q relationship. These results demonstrate that the MSCP is a promising device for long-term use.


2002 ◽  
Vol 2002 (0) ◽  
pp. 183-184
Author(s):  
Takayuki KODAMA ◽  
Takashi YAMANE ◽  
Hiroshi KAWAMURA ◽  
Yoshiro YAMAMOTO ◽  
Toshiyuki SHINOHARA

2007 ◽  
Vol 133 (2) ◽  
pp. 577-578 ◽  
Author(s):  
Stephen Westaby ◽  
Lognathen Balacumaraswami ◽  
Betsy J. Evans ◽  
Gabriele B. Bertoni ◽  
Xu Y. Jin ◽  
...  

2011 ◽  
Vol 35 (5) ◽  
pp. 437-442 ◽  
Author(s):  
Eduardo Bock ◽  
Pedro Antunes ◽  
Tarcisio Leao ◽  
Beatriz Uebelhart ◽  
Jeison Fonseca ◽  
...  

2000 ◽  
Vol 24 (6) ◽  
pp. 437-441 ◽  
Author(s):  
Yukihiko Orime ◽  
Motomi Shiono ◽  
Shinya Yagi ◽  
Tomonori Yamamoto ◽  
Haruhiko Okumura ◽  
...  