Qualitative and Quantitative Assessment of Alveolar Bone Destruction in Adult Rats Using CBCT

2019 ◽  
Vol 36 (4) ◽  
pp. 245-250
Author(s):  
Kıvanç Kamburoğlu ◽  
Gülden Ereş ◽  
Ceren Akgün

Cone-beam computed tomography (CBCT) has strong potential to be utilized in various aspects of veterinary dentistry. Using ex vivo rat maxillary bone and teeth, the purpose of this study was to compare gray value, surface area, and volumetric measurements of teeth with and without experimental periodontitis by CBCT. Periodontitis was induced in 36 molar teeth, while 36 teeth with a healthy periodontium served as control. Images of each specimen along with teeth were obtained using CBCT. The following measurements for each tooth with periodontitis (n = 36) were recorded: gray value measurement, width, height, depth, surface area, and volume of the alveolar bone loss. For the control group (n = 36), gray value measurement, surface area, and volume of the alveolar bone were recorded. All measurements were repeated after 3 weeks. As the gold standard, the rat maxillas were decalcified and paraffin-embedded for further immunocytochemical study. One-way analysis of variance (ANOVA) was used. Significance level was set at P < .05. Correlation values for gray value, width, height, depth, surface area, and volume measurements were 0.983, 0.966, 0.962, 0.880, 0.998, and 0.999, respectively, for the first and second measurements. One way ANOVA showed statistically significant differences between teeth with and without alveolar bone destruction conducted for gray value, surface area, and volume measurements ( P = .000). Mean gray value, surface area, and volume measurements decreased 56.46%, 81.89%, and 78.56%, respectively, for teeth with alveolar bone destruction in comparison to healthy teeth. Cone-beam computed tomography provided useful qualitative and quantitative information regarding induced periodontitis in the rat maxilla.

2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Kyungmin Lee ◽  
Gyu-Hyoung Lee

Abstract Background Radiographs are integral in evaluating implant space and inter-root distance. The purpose of this report is to introduce a method for evaluating the 3D root position with minimal radiation using a 3D tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography (CBCT)-scanned root. Materials and methods Intraoral scan and CBCT scan of the patient were obtained before treatment. In the CBCT image, tooth segmentation was performed by isolating individual teeth from the maxillary and mandibular alveolar bone using software program. The 3D tooth model was fabricated by combining segmented individual teeth with the intraoral scan. Results A post-treatment intraoral scan was integrated into the tooth model, and the resulting position of the root could be predicted without additional radiographs. It is possible to monitor the root position after a pretreatment CBCT scan using a 3D tooth model without additional radiographs. Conclusion The application of the 3D tooth model benefits the patient by reducing repeated radiation exposure while providing the clinician with a precise treatment evaluation to monitor tooth movement.


Author(s):  
Marcin Stasiak ◽  
Anna Wojtaszek-Słomińska ◽  
Bogna Racka-Pilszak

Abstract Purpose The aims of this retrospective cross-sectional study were to measure and compare labial and palatal alveolar bone heights of maxillary central incisors in unilateral cleft lip and palate patients, following STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) guidelines. Patients and methods The study group consisted of 21 patients with a mean age of 16 years. High-resolution cone-beam computed tomography was performed at least one year after secondary alveolar bone grafting. The experimental side was the cleft side and the contralateral side without congenital cleft was the control. Measurements were performed on incisors’ midsagittal cross-sections. The Wilcoxon signed-rank test was used for intergroup comparisons. Results The labial and palatal distances between alveolar bone crests and cementoenamel junctions were significantly greater on the cleft side than on the noncleft side. Mean differences were 0.75 and 1.41 mm, respectively. The prevalence of dehiscences at the cleft side maxillary central incisors was 52% on the labial surface and 43% on the palatal surface. In the controls, it was 19% and 14%, respectively. Conclusion The cleft-adjacent maxillary central incisors had more apically displaced alveolar bone crests on the labial and palatal sides of the roots than the controls. Higher prevalence of dehiscences was found on the cleft side. Bone margin differences predispose to gingival height differences of the central incisors. These differences could increase the demands of patients to obtain more esthetic treatment results with orthodontic extrusion and periodontal intervention on the cleft side.


2021 ◽  
Vol 12 (3) ◽  
pp. 230-233
Author(s):  
Piyush Gupta ◽  
Nivedita Sahoo ◽  
Kavuda Nagarjuna Prasad ◽  
MS Rami Reddy ◽  
Saranya Sreedhar ◽  
...  

2020 ◽  
Vol 26 (2) ◽  
pp. 195-200
Author(s):  
Gamze NALCI ◽  
Tayfun ALAÇAM ◽  
Elshad SALMANOV ◽  
Muhsin Said KARATAŞ ◽  
Cemile Özlem ÜÇOK

2017 ◽  
Vol 40 (6) ◽  
pp. 307-312 ◽  
Author(s):  
Bence T. Szabo ◽  
Seçil Aksoy ◽  
Gabor Repassy ◽  
Krisztian Csomo ◽  
Csaba Dobo-Nagy ◽  
...  

Introduction The aim of this study was to compare the paranasal sinus volumes obtained by manual and semiautomatic imaging software programs using both CT and CBCT imaging. Methods 121 computed tomography (CT) and 119 cone beam computed tomography (CBCT) examinations were selected from the databases of the authors’ institutes. The Digital Imaging and Communications in Medicine (DICOM) images were imported into 3-dimensonal imaging software, in which hand mode and semiautomatic tracing methods were used to measure the volumes of both maxillary sinuses and the sphenoid sinus. The determined volumetric means were compared to previously published averages. Results Isometric CBCT-based volume determination results were closer to the real volume conditions, whereas the non-isometric CT-based volume measurements defined coherently lower volumes. By comparing the 2 volume measurement modes, the values gained from hand mode were closer to the literature data. Furthermore, CBCT-based image measurement results corresponded to the known averages. Conclusions Our results suggest that CBCT images provide reliable volumetric information that can be depended on for artificial organ construction, and which may aid the guidance of the operator prior to or during the intervention.


Sign in / Sign up

Export Citation Format

Share Document