Study on the damping efficiency of continuous beam bridge with constant cross-section applied by lead rubber bearings and fluid viscous dampers

2020 ◽  
Vol 51 (4-5) ◽  
pp. 85-92
Author(s):  
Li Zhen ◽  
Li Dejian ◽  
Peng Leihua ◽  
Lu Yao ◽  
Cheng Kepei ◽  
...  

Bridges are the lifelines of disasters in earthquake areas. Therefore, it is very necessary to ensure the safety and traffic function after earthquake. Seismic isolation refers to install external energy dissipation devices or external energy input devices in specific parts of engineering structures. There are certain differences in longitudinal and transverse seismic responses of multi-span continuous beam bridges by changing the seismic dynamic characteristics or dynamic effects of structures. It is difficult to achieve the purpose of seismic isolation in both horizontal directions using isolation devices alone. The rubber deformation ability of lead rubber bearings can effectively insulate, and the yield energy consumption ability of its lead core can effectively consume the seismic energy for damping. The horizontal resistance is very small under the creep load, and the stiffness decreases rapidly after yielding under the strong dynamic earthquake load; meanwhile, the seismic energy is dissipated by the hysteresis of bearing. Fluid viscous damper is a velocity-dependent energy dissipation device, which produces viscous damping force, provides strong restoring force for components, and has a good limit function. This process will also dissipate the seismic energy, so as to reduce the structural earthquake response. Using these two methods together, the horizontal seismic responses of multi-span continuous beam bridges can be effectively controlled at the same time. Based on this idea, this article takes a high-speed multi-span continuous beam bridge with equal section as the engineering background, and uses dynamic time history analysis method to discuss the seismic isolation effect of lead rubber bearings and fluid viscous dampers.

2011 ◽  
Vol 194-196 ◽  
pp. 2008-2013
Author(s):  
Bin Yan

Continuous beam bridge was widely used, while seismic problem of it was prominent in meizoseismal area. According to seismic-isolation principle and mechanism of PSD, seismic performance of PSD were studied and the parameters of PSD were analyzed later, based on south approach of North Branch of Xia-Zhang Sea-Crossing Bridge. It was found that PSD, a combination of preloaded spring and liquid viscous damper, was an effective seismic-isolation device which could significantly reduce the seismic response of continuous beam bridge in longitudinal and transverse direction. Damper coefficient was the main parameter of PSD, while preloaded force, linear spring stiffness and damper index had a little effect on seismic performance of PSD.


2020 ◽  
Vol 2020 ◽  
pp. 1-22
Author(s):  
Yumin Zhang ◽  
Jiawu Li ◽  
Lingbo Wang ◽  
Hao Wu

Rubber isolation bearings have been proven to be effective in reducing the seismic damage of bridges. Due to the different characteristics of isolation bearings, the mechanical properties of bridges with different combinations of rubber bearings are complex under the action of earthquakes. This paper focuses on the application of combinations of rubber isolation bearings on seismic performance of continuous beam bridges with T-beams. The seismic performances of continuous beam bridges with different combinations of rubber isolation bearings, pier height, and span length were studied by the dynamic time history analysis method. It was found that the bridges with natural rubber bearings (NRBs) have the largest seismic responses compared to the other types of bearings. The continuous beam bridge with isolation bearings, such as lead rubber bearings (LRBs) and high damping rubber bearings (HDRBs), has approximately 20%∼30% smaller seismic response than that with NRBs under the action of earthquakes due to the hysteretic energy of the bearings, indicating that the isolation bearings improve the seismic performance of the bridge. The continuous beam bridges with both NRBs and LRBs or NRBs and HDRBs have larger seismic response of the piers than those with a single type of isolation bearings (LRBs or HDRBs) but smaller seismic response of the piers than those with only NRBs. For a continuous beam bridge with shorter span and lower pier, it is not economical to use LRBs or HDRBs underneath every single girder, but it is more reasonable to use cheaper NRBs underneath some girders. The larger difference in stiffness of the bearings between the side and middle piers leads to the more unbalanced seismic response of each pier of the bridge structure. The results also show that with increasing pier height and span length, the difference in the seismic response value between the cases gradually increases.


2011 ◽  
Vol 255-260 ◽  
pp. 2488-2491
Author(s):  
Bin Yan ◽  
Peng Liu

Continuous Beam Bridge was widely used, while seismic problem of it was prominent in meizoseismal area. According to mechanism of DSB, seismic performance of DSB was studied and the parameters of DSB were analyzed later, based on non-navigable bridge of Hong Kong-Zhuhai-Macau Bridge in deep water. It was found that DSB was an effective seismic-isolation device which could significantly reduce the seismic force although seismic displacement of bridge was increased. Yielding force and post-yielding stiffness were two main parameters of DSB.