An evaluation of bias in propensity score-adjusted non-linear regression models

2016 ◽  
Vol 27 (3) ◽  
pp. 846-862 ◽  
Author(s):  
Fei Wan ◽  
Nandita Mitra

Propensity score methods are commonly used to adjust for observed confounding when estimating the conditional treatment effect in observational studies. One popular method, covariate adjustment of the propensity score in a regression model, has been empirically shown to be biased in non-linear models. However, no compelling underlying theoretical reason has been presented. We propose a new framework to investigate bias and consistency of propensity score-adjusted treatment effects in non-linear models that uses a simple geometric approach to forge a link between the consistency of the propensity score estimator and the collapsibility of non-linear models. Under this framework, we demonstrate that adjustment of the propensity score in an outcome model results in the decomposition of observed covariates into the propensity score and a remainder term. Omission of this remainder term from a non-collapsible regression model leads to biased estimates of the conditional odds ratio and conditional hazard ratio, but not for the conditional rate ratio. We further show, via simulation studies, that the bias in these propensity score-adjusted estimators increases with larger treatment effect size, larger covariate effects, and increasing dissimilarity between the coefficients of the covariates in the treatment model versus the outcome model.

2009 ◽  
Vol 6 (1) ◽  
pp. 115-141 ◽  
Author(s):  
P. C. Stolk ◽  
C. M. J. Jacobs ◽  
E. J. Moors ◽  
A. Hensen ◽  
G. L. Velthof ◽  
...  

Abstract. Chambers are widely used to measure surface fluxes of nitrous oxide (N2O). Usually linear regression is used to calculate the fluxes from the chamber data. Non-linearity in the chamber data can result in an underestimation of the flux. Non-linear regression models are available for these data, but are not commonly used. In this study we compared the fit of linear and non-linear regression models to determine significant non-linearity in the chamber data. We assessed the influence of this significant non-linearity on the annual fluxes. For a two year dataset from an automatic chamber we calculated the fluxes with linear and non-linear regression methods. Based on the fit of the methods 32% of the data was defined significant non-linear. Significant non-linearity was not recognized by the goodness of fit of the linear regression alone. Using non-linear regression for these data and linear regression for the rest, increases the annual flux with 21% to 53% compared to the flux determined from linear regression alone. We suggest that differences this large are due to leakage through the soil. Macropores or a coarse textured soil can add to fast leakage from the chamber. Yet, also for chambers without leakage non-linearity in the chamber data is unavoidable, due to feedback from the increasing concentration in the chamber. To prevent a possibly small, but systematic underestimation of the flux, we recommend comparing the fit of a linear regression model with a non-linear regression model. The non-linear regression model should be used if the fit is significantly better. Open questions are how macropores affect chamber measurements and how optimization of chamber design can prevent this.


2008 ◽  
Vol 37 (5) ◽  
pp. 1142-1147 ◽  
Author(s):  
Edwin P Martens ◽  
Wiebe R Pestman ◽  
Anthonius de Boer ◽  
Svetlana V Belitser ◽  
Olaf H Klungel

2018 ◽  
Vol 44 (2) ◽  
pp. 203-213 ◽  
Author(s):  
Sindhu R. Johnson ◽  
George A. Tomlinson ◽  
Gillian A. Hawker ◽  
John T. Granton ◽  
Brian M. Feldman

Symmetry ◽  
2021 ◽  
Vol 13 (12) ◽  
pp. 2331
Author(s):  
Sergey Lychev ◽  
Konstantin Koifman ◽  
Nikolay Djuzhev

The present paper is intended to show the close interrelationship between non-linear models of solids, produced with additive manufacturing, and models of solids with distributed defects. The common feature of these models is the incompatibility of local deformations. Meanwhile, in contrast with the conventional statement of the problems for solids with defects, the distribution for incompatible local deformations in additively created deformable body is not known a priori, and can be found from the solution of the specific evolutionary problem. The statement of the problem is related to the mechanical and physical peculiarities of the additive process. The specific character of incompatible deformations, evolved in additive manufactured solids, could be completely characterized within a differential-geometric approach by specific affine connection. This approach results in a global definition of the unstressed reference shape in non-Euclidean space. The paper is focused on such a formalism. One more common factor is the dataset which yields a full description of the response of a hyperelastic solid with distributed defects and a similar dataset for the additively manufactured one. In both cases, one can define a triple: elastic potential, gauged at stress-free state, and reference shape, and some specific field of incompatible relaxing distortion, related to the given stressed shape. Optionally, the last element of the triple may be replaced by some geometrical characteristics of the non-Euclidean reference shape, such as torsion, curvature, or, equivalently, as the density of defects. All the mentioned conformities are illustrated in the paper with a non-linear problem for a hyperelastic hollow ball.


2015 ◽  
Vol 72 (12) ◽  
pp. 2262-2269 ◽  
Author(s):  
Rubina Sahin ◽  
Kavita Tapadia

The three widely used isotherms Langmuir, Freundlich and Temkin were examined in an experiment using fluoride (F−) ion adsorption on a geo-material (limonite) at four different temperatures by linear and non-linear models. Comparison of linear and non-linear regression models were given in selecting the optimum isotherm for the experimental results. The coefficient of determination, r2, was used to select the best theoretical isotherm. The four Langmuir linear equations (1, 2, 3, and 4) are discussed. Langmuir isotherm parameters obtained from the four Langmuir linear equations using the linear model differed but they were the same when using the nonlinear model. Langmuir-2 isotherm is one of the linear forms, and it had the highest coefficient of determination (r2 = 0.99) compared to the other Langmuir linear equations (1, 3 and 4) in linear form, whereas, for non-linear, Langmuir-4 fitted best among all the isotherms because it had the highest coefficient of determination (r2 = 0.99). The results showed that the non-linear model may be a better way to obtain the parameters. In the present work, the thermodynamic parameters show that the absorption of fluoride onto limonite is both spontaneous (ΔG < 0) and endothermic (ΔH > 0). Scanning electron microscope and X-ray diffraction images also confirm the adsorption of F− ion onto limonite. The isotherm and kinetic study reveals that limonite can be used as an adsorbent for fluoride removal. In future we can develop new technology for fluoride removal in large scale by using limonite which is cost-effective, eco-friendly and is easily available in the study area.


Sign in / Sign up

Export Citation Format

Share Document