The Effect of the XM45 Gas Mask and Hood on Directional Hearing

Author(s):  
T. R. Letowski ◽  
G. L. Ricard ◽  
J. E. Greives

We measured listeners' directional sensitivity for narrow bands of noise and for speech recognition while they were wearing the XM45 gas mask and hood and compared it to normal free-field listening. Bekesy tracking was used to measure absolute hearing thresholds for 1/3 octave bands of noise centered at 0.125, 0.25, 0.5, 1, 2, 3, 4, 6, and 8 kHz. and masked intelligibility thresholds for speech were measured using the Modified Rhyme Test. Both the noise and speech signals were presented from loudspeakers located at azimuths of 0°, 45°, 90°, 135°, and 180°. The mask and hood significantly elevated noise-band thresholds for those bands centered at 1.0 kHz and above. Sensitivity to masked speech was increased by over 12 dB by lateral loudspeaker placement, and wearing a gas mask and hood reduced this gain by 80 percent. These results document a loss of auditory spatial awareness that has not been apparent from previous studies of speech intelligibility while wearing chemical protective equipment.

1980 ◽  
Vol 86 (1) ◽  
pp. 153-170
Author(s):  
R. B. COLES ◽  
D. B. LEWIS ◽  
K. G. HILL ◽  
M. E. HUTCHINGS ◽  
D. M. GOWER

The directional sensitivity of cochlear microphonics (CM) was studied inthe quail by rotating a free-field sound source (pure tones, 160-10 kHz)through 360° in the horizontal plane, under anechoic conditions. Sound diffraction by the head was monitored simultaneously by a microphone at the entrance to the ipsilateral (recorded) ear canal. Pressure-field fluctuations measured by the microphone were non-directional (≤ 4 dB) up to 4 kHz; the maximum head shadow was 8 dB at 6.3 kHz. In comparison, the CM sensitivity under went directional fluctuations ranging up to 25 dB for certain low, mid and high frequency band widths. There was noticeable variation between quail for frequencies producing maximum directional effects, although consistently poor directionality was seen near 820 Hz andto a lesser extent near 3.5 kHz. Well-defined CM directivity patterns reflected the presence of nulls (insensitive regions) at critical positions around the head and the number of nulls increased with frequency. Five major types of directivity patterns were defined using polar co-ordinates: cardioid, supercardioid, figure-of-eight, tripartite and multilobed. Such patterns were largely unrelated to head shadow effects. Blocking the ear canal contralateral to there corded ear was shown to effectively abolish CM directionality, largely by eliminating regions of insensitivity to sound. It is inferred that the quail ear functions as an asym metrical pressure gradient receiver, the pressure gradient function being mediated by the interauralcavity. It is proposed that the central auditory system codes directional information by a null detecting method and computes an unambiguous (i.e.intensity independent) directional cue. This spatial cue is achieved by the difference between the directional sensitivities of the two ears, defined as the Directional Index (DI). The spatial distribution of DI values (difference pattern) demonstrated ranges and peaks which closely reflected the extent and position of nulls determined from monaural directivity functions. Large directional cues (up to 25 dB) extended throughout most of the audible spectrum of the quail and the sharpness of difference patterns increased with frequency. Primary ‘best’ directions, estimated from peaks in difference patterns, tended to move towards the front of the head at higher frequencies; rearward secondary peaks also occurred. From the properties of directional cues it is suggested that the ability of birds to localize sound need not necessarily depend on frequency; however, spatial acuity may be both frequency and direction dependent, and include the possibility of front-torearerrors. The directional properties of bird vocalizations may need to bere assessed on the basis of the proposed mechanism for directional hearing.


2020 ◽  
Vol 129 (12) ◽  
pp. 1221-1228
Author(s):  
Chunli Zhao ◽  
Jinsong Yang ◽  
Yujie Liu ◽  
Mengdie Gao ◽  
Peiwei Chen ◽  
...  

Objective: To evaluate the long-term safety and efficacy of the Clip coupler attached to the stapes head in patients with unilateral congenital aural atresia (CAA). Methods: This single-center retrospective study included 16 Mandarin-speaking patients who had unilateral microtia accompanied by CAA. All patients were divided into two groups: the short-term follow-up group (n = 9) and the long-term follow-up group (n = 7). The floating mass transducer of the Vibrant Soundbridge (VSB) was positioned in the stapes head by the Clip coupler. The safety of the VSB was investigated by comparing preoperative and postoperative bone-conduction (BC) thresholds as well as by complications. The effectiveness was evaluated by functional gain (FG), word recognition score (WRS), speech reception threshold (SRT) and signal-to-noise ratio (SNR). Results: Pre- and post-operative BC thresholds were no different in all patients. And no complications developed. VSB-aided thresholds in the free-field had improved significantly in both short- and long-term follow-up groups. The improvements of WRS were observed in two groups. The monosyllabic VSB-aided WRS in the long-term follow-up group was significantly higher than that in the short-term follow-up group. When speech was from the impaired ear and noise presented to the side of normal ear (SVSBNCL), lower SNRs were found in two groups after VSB implantation. However, there was no statistical difference in aided SNR between the two groups at SVSBNCL status. Conclusions: Our results show that the FMT connected to the stapes head is a secure and useful device for patients with unilateral CHL/MHL, not only in terms of improved hearing thresholds, but also improved speech intelligibility in quiet and noisy environments.


2019 ◽  
Vol 62 (9) ◽  
pp. 3290-3301
Author(s):  
Jingjing Guan ◽  
Chang Liu

Purpose Degraded speech intelligibility in background noise is a common complaint of listeners with hearing loss. The purpose of the current study is to explore whether 2nd formant (F2) enhancement improves speech perception in noise for older listeners with hearing impairment (HI) and normal hearing (NH). Method Target words (e.g., color and digit) were selected and presented based on the paradigm of the coordinate response measure corpus. Speech recognition thresholds with original and F2-enhanced speech in 2- and 6-talker babble were examined for older listeners with NH and HI. Results The thresholds for both the NH and HI groups improved for enhanced speech signals primarily in 2-talker babble, but not in 6-talker babble. The F2 enhancement benefits did not correlate significantly with listeners' age and their average hearing thresholds in most listening conditions. However, speech intelligibility index values increased significantly with F2 enhancement in babble for listeners with HI, but not for NH listeners. Conclusions Speech sounds with F2 enhancement may improve listeners' speech perception in 2-talker babble, possibly due to a greater amount of speech information available in temporally modulated noise or a better capacity to separate speech signals from background babble.


2020 ◽  
Vol 25 (3) ◽  
pp. 164-172
Author(s):  
Denise Zimmermann ◽  
Susan Busch ◽  
Thomas Lenarz ◽  
Hannes Maier

Background: Since its introduction in 1996, the Vibrant Soundbridge (VSB) has been upgraded with several improved generations of processors. As all systems are compatible, implanted patients can benefit from new technologies by upgrading to the newest processor type available. Objectives: The aim of this study was to compare the performance of the new (current) SAMBA processor with the previous Amadé processor. Methods: Twenty subjects monaurally implanted with a VSB and the Amadé processor tested the new SAMBA processor for a trial period of 4 weeks. We measured air conduction and bone conduction thresholds, unaided thresholds, and aided free field thresholds with both devices. Speech performance in quiet using the Freiburg monosyllabic test at 65 dB SPL (S0) was compared. The speech intelligibility in noise was determined using the Oldenburg sentence test measured in different listening conditions (S0NVSB/S0Ncontra) and microphone settings (omni/directional vs. adaptive directivity). Results: Word recognition scores in quiet with the SAMBA were still significantly lower than with the Amadé after the 4 weeks trial period but improved over the following year. Speech intelligibility with the SAMBA was significantly better than with the Amadé in omnidirectional mode and comparable with the Amadé in directional mode. Hence, the adaptive directionality provides an advantage in difficult hearing situations such as noisy environments. The subjective benefit was evaluated using the Abbreviated Profile of Hearing Aid Benefit and the Speech, Spatial and Qualities-C questionnaire. Results of the questionnaires demonstrate an overall higher level of satisfaction with the new SAMBA speech processor than with the older processor. Conclusion: The SAMBA enables similar speech perception in quiet but more flexible adaptation in acoustically challenging environments compared to the previous Amadé processor.